Theben S KNX 9070880 - Line Coupler Manual

Safety

  • Installation should only be carried out by professional electrician!
  • Disconnect the mains power supply prior to installation and/or disassembly!
  • Note detailed operating manual on the internet!

General information

  • The line coupler S KNX enables the exchange of data between two separate KNX bus lines
  • The line coupler S KNX both lines can be used independently from each other
  • The line coupler S KNX can be used as an area coupler, line coupler or line amplifier
  • Telegrams can be filtered (to reduce telegram traffic)

Technical data

Operating voltage: 31 V DC
Standby: 0,25 W
Protection rating: IP 20
Protection class: III subject to correct installation
Operating temperature: –5°C... +45°C
Bus voltage KNX: 21 – 32 V DC
Power consumption KNX bus: ≤ 10 mA
Pollution degree: 2
Rated impulse voltage: 0,8 kV

warning Protect the unit against moisture, dirt and damage during transport, storage and operation.
warning Always operate the unit within the specified technical data.
warning The unit may only be operated in closed enclosures (e.g. distribution boxes). Do not open the device.

Designated Use

  • For connection KNX lines or areas

Installation

  • The unit is designed to be installed in distribution boxes or small housings for quick mounting on 35 mm support rails in accordance with EN 60715

Connection

  • Disconnect power source
  • The terminal identifiers can be found on the housing
  • The connection to KNX is made via the supplied bus terminal
    Connection

Start-up and operation

Device Overview

  1. Label carrier
  2. Programming button
  3. Programming LED
  4. Bus terminal for the KNX connection of the primary/main line
  5. Bus terminal for the KNX connection of the secondary line
  6. LED for telegram traffic on the secondary line
  7. LED for telegram traffic on the primary/main line
  8. Power LED
  • Connect power supply.
  • Commissioning of the system is carried out using the Engineering Tool Software (ETS)

Operation

  • On : LED lights green when voltage is applied and the device is ready for operation
  • Main Line : LED lights yellow when the main line is connected; flashes when there is telegram traffic on the main line
  • Line : LED lights yellow when the line is connected; flashes when there is telegram traffic on the line
  • Programming LED lights red when the device is in the programming mode (after the programming button has been pressed)

Dimensions

Dimensions

The ETS database is available at www.theben.de.
Please refer to the KNX manual for detailed functional descriptions.

Further information http://qr.theben.de/p/9070880en

Hotline Theben:
+49 7474 692-369

Documents / Resources

References

Download manual

Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.

Download Theben S KNX 9070880 - Line Coupler Manual

Advertisement

Need Assistance?

Do you have a question about the S KNX 9070880 that isn't answered in the manual? Leave your question here.

Error while submitting your question. Please, reload page and try again.

Thank you! Your question has been received!

Table of Contents