Programming with LUXORplug Operation with LUXORplay Users and authorisations Scenes "Time switch" function LUXORplay settings LUXORliving – the Theben Cloud Add other users Cloud access for an existing user Integration of personal assistants LUXORliving and Amazon Alexa LUXORliving and Google Home...
General 1 General LUXORliving smart home control is based on a bus communication and includes control of lighting, actuators and indoor climate. LUXORliving is taken into operation by using the free LUXORplug programming tool. (http://luxorliving.de/luxorplug/) LUXORplug assigns all functions, which can also be changed later on.
All components of LUXORliving communicate via a bus connection according to the KNX standard (KNX S-mode). • The connection to the home network is via the LUXORliving IP1 system control centre. This allows operation via the LUXORplay app. • The system can be equipped with a maximum of 64 LUXORliving devices, which includes system devices, sensors and actuators.
Installation 3 Installation • The components of LUXORliving are intended for installation in a switch cabinet, in a flush-mounted box, or for wall mounting. • Communication is via a 2-wire bus, to which each device has to be connected. The bus connection can be executed as a line, star or tree topology.
Page 6
Please note that outdoors, a bus line can pose an increased safety risk. As an alternative in the outdoor area, normal motion detectors with relay contact can for instance be integrated into the system via the LUXORliving B6 binary input. When using the LUXORliving M140 weather station, installation location and cable routing should be chosen in a way, so access to the bus line is difficult.
First, complete the formalities by entering all relevant product information, such as the project name, builder, address and installer. 4.2 Create overview Using drag & drop, you can add the rooms to the relevant floors and assign them individual names. LUXORliving system manual...
Use drag & drop to add functions to the devices in each room. This determines which devices communicate with each other. 4.5 Program functions These functions can be transferred at any time. The project planning does not have to be completely finished to program the devices. LUXORliving system manual...
Simple start-up in 6 steps 4.6 Prepare visualisation The project file is transmitted to the system control centre. The functions are then extremely easy to operate and configure using the LUXORplay app. LUXORliving system manual...
We recommend the connection via a router. 5.1.1 Option 1 – Connection via a router Connect PC (WLAN or LAN) and LUXORliving IP1 system control centre (LAN) with the router and switch on the power supply of the LUXORliving IP1 system control centre.
Page 11
5.1.2 Option 2 – Connection without router using the DHCP service of LUXORplug Via an integrated DHCP service in LUXORplug, an IP address can be assigned to the LUXORliving IP1 system control centre and the PC. This changes the network settings, which requires the appropriate access rights.
Page 12
Afterwards, an IP address will be assigned to the LUXORliving IP1 system control centre as well as the PC. If LUXORliving IP1 has not received an IP address from the PC, LUXORliving IP1 must be restarted, or the direct connection may have to be repeated.
Start-up with LUXORplug Undo these settings after finishing your activities in the LUXORliving system and activate DHCP. At LUXORliving IP1, the IP address has to be set manually as well: Press the " " button and open the "IP Config" menu with the "...
Page 14
Direct connection to LUXORliving IP1 This function is used if LUXORliving IP1 is connected directly to the PC via a LAN cable. When activated, a DHCP service is started in LUXORplug, which automatically assigns an IP address to LUXORliving IP1 and to the PC. For this, the network settings of LUXORliving IP1 and PC must have activated the DHCP service.
Page 15
5.2.1.1 Define floors and rooms By navigating with the arrow icons, you can go one menu step ahead () or back (). In the next step, you can define the number of floors and include the corresponding rooms on each floor. LUXORliving system manual...
Page 16
Edit floors or rooms Click on the pin. In this way, you can change the names of rooms and floors. Click on a room (e.g. bedroom) → A choice of alternative icons for the respective room is displayed. LUXORliving system manual...
Page 17
In the next step, you can load the system. In order to do this, the PC must be connected to LUXORliving IP1 and other LUXORliving components. As an alternative, you can skip this step and create the device list manually.
Page 18
Start-up with LUXORplug Click on the "Load system" field. Before the connected LUXORliving components are loaded automatically, the user is prompted to enter the password for the LUXORliving IP1 system control centre. The default password is "admin". For security reasons, LUXORplug prompts the user to change the password. The user can then create a new, secure password.
Page 19
Start-up with LUXORplug If the password is forgotten, the LUXORliving IP1 system control centre will need to be reset with a master reset. This can be done directly at the device ("Reset" menu – "Master Reset"). Afterwards, the password can be created again via LUXORplug. The default password after a master reset is always "admin".
Page 20
3 times. The "magnifying glass" icon then indicates the respective device. The identification can be finished by pressing the button again briefly. After all devices have been identified and clearly named, configuration can be completed with "". LUXORliving system manual...
Page 21
Start-up with LUXORplug 5.2.1.5 Create the device list manually If the PC is not connected to the LUXORliving system, or the LUXORliving components are not linked with each other, the device list can be created manually. This function allows configuration, without the installation being already started or completed.
Page 22
3 times. After that, one of the green-coloured device fields on the right side flashes and indicates the respective device. Press the button again briefly. The identification will be finished again. LUXORliving system manual...
Page 23
2. Devices programmed with the ETS 3. Devices to be replaced in the system 4. New devices to be added to the installation The device found is displayed on the right side and can be added to the system. LUXORliving system manual...
Page 24
Click on the "Rooms" field. The building view will be opened and allows a room-based configuration of functions. Click on the desired room, for instance the bedroom. Draw the desired function to the right and into the room. LUXORliving system manual...
Page 25
Start-up with LUXORplug On the right side, devices appropriate for the selected function are displayed. LUXORliving system manual...
Page 26
Function after voltage recovery: Channels configured as basement and staircase light functions switch ON for the set time. Afterwards, a "trigger" can be assigned to the switching channel. (A maximum of 8 trigger pairs can be assigned to one channel). LUXORliving system manual...
Page 27
The window with the central and group functions is opened. Here, the channel can be integrated into existing group functions, and own groups can be added. The thresholds for twilight functions can be set in the settings of the weather station. LUXORliving system manual...
Page 28
Start-up with LUXORplug A "trigger", e.g. the channel of a button interface, can be drawn on a group function and thus be triggered with this participant. LUXORliving system manual...
Page 29
The dimming time defines the dimming speed for the complete dimming range 0 …100 % Minimum dimming value: Adjustment to the connected lamp. If the lamp flickers, e.g. with dimming values < 10 %, the minimum dimming value has to be limited to 10 %. LUXORliving system manual...
Page 30
Fixed value: The colour picker that appears is used to set which colour or colour temperature is used when switching on. Time for colour change: This parameter is used to decide how quickly the colour value is changed. LUXORliving system manual...
Page 31
If the colour picker symbol is pressed, the colour or colour temperature to be controlled when switching on can be set in the colour field. RGBW Color temperature Afterwards, a "trigger" can be assigned to the dimming channel. (A maximum of 8 trigger pairs can be assigned to one channel.) LUXORliving system manual...
Page 32
The thresholds for twilight functions can be set in the settings of the weather station. A "trigger", e.g. the channel of a button interface, can be drawn on a group function and thus be triggered with this participant. LUXORliving system manual...
Page 33
Scene trigger • Group trigger Parameters of LUXORliving BI 180 WH as trigger for "Switching" and "Dimming": Function: "Master” sends the On/Off command. The brightness and time delay settings are only available with the "Master". Only 1 master can be linked to a function/channel.
Page 34
In the parameter window, the function can be named and various parameters can be set. Application "blinds" For each blinds channel, the entire runtime, the time for a turn (step), as well as the participation in functions of the weather station can be set individually. LUXORliving system manual...
Page 35
For an awning, the response to one of the alarm functions is: "Close" = "Extend awning". Afterwards, a "trigger" can be assigned to the awning channel. (A maximum of 8 trigger pairs can be assigned to one channel.) LUXORliving system manual...
Page 36
(C1, C3, C5, C7), and the second trigger will be added automatically (C2, C4, C6, C8). Consider the following when installing the buttons at a button interface: Button/command UP = C1, C3, C5 or C7 Button/command DOWN = C2, C4, C6 or C8 LUXORliving system manual...
Page 37
The thresholds for sun protection or twilight function can be set in the settings of the weather station. A "trigger", e.g. the channel of a button interface, can be drawn on a group function and thus be triggered with this participant. LUXORliving system manual...
Page 38
Start-up with LUXORplug 5.2.2.5 Heating with LUXORliving H1, H1 RF, H6, H6 24V Pull the appropriate channel of a heating actuator to the "heating actuator" field. The parameter window of this heating function is opened. In the parameter window, the function can be named and various parameters can be set.
Page 39
5.2.2.6 Heating with LUXORliving E1, E1 RF LUXORliving E1, E1 RF is a heating actuator for controlling electric heaters, switching (2-point). LUXORliving E1 can be used as a room thermostat (heating or cooling) or as an additional stage for heating.
Page 40
Start-up with LUXORplug External inputs: The device has 2 external inputs for push buttons, switches, etc. Input I2 can also be used as a temperature input, e.g. as a floor sensor. LUXORliving system manual...
Page 41
Room calibration allows a subsequent adjustment of the temperature measurement. In addition, the LUXORliving R718 room sensor has 4 binary inputs (sensors), which can also be used as triggers for a function. Function of LEDs on the device (only LUXORliving R718) Display on LED 1 (above the rotary control): •...
Page 42
Start-up with LUXORplug 5.2.2.8 "Favourites" function of LUXORliving iON8 When using the iON8 room sensor, there is a favourite option. If the room sensor is set as a favourite, the device display changes to room controller mode after one minute (only for favourite A).
Page 43
Start-up with LUXORplug Temperature measurement via LUXORliving (without room sensor) In the parameter window, the function can be named and a room calibration can be set. Room calibration allows a subsequent adjustment of the temperature measurement. When measuring the temperature, the desired set temperature can only be set via the LUXORplay app.
Page 44
The window with the central and group functions is opened. In control type "Heating and cooling", a "trigger", e.g. a channel of a button interface, can be drawn on the "Heating/cooling" group function, and the configuration type can be set. LUXORliving system manual...
Page 45
(by ticking the box). The participating channels are now controlled by a sensor. The red box shows the channels participating in the "Heating group", which is linked to a room sensor. LUXORliving system manual...
Page 46
Manual operating commands (up/down) and alarm functions (e.g. wind, rain, frost) are executed unchanged even when the door is open. Only one window contact per channel may be assigned. The setting "Operation with closed contact" depends on the contact used (NO contact (NO) or opening contact (NC)). LUXORliving system manual...
Page 47
The window contacts that are already assigned in one room cannot be used in another room. Door and window contacts in LUXORplay Each open-door contact is also shown in our LUXORplay visualisation: By pressing the "Caution" icon, the rooms in which the windows are open are displayed. LUXORliving system manual...
Page 48
(BI 180 WH), for triggering saved scenes. The participants and operations of the scenes are completely added and configured in the LUXORplay app. After adding a scene trigger, a trigger (e.g. a channel of a button interface) can be connected. LUXORliving system manual...
Page 49
For the selection of value (temperature), a text for the unit can be entered. These texts will be displayed in the LUXORliving app for the respective status or the unit. All triggers not yet used can be linked as "triggers" (inputs of e.g. push button interfaces, binary inputs and flush-mounted actuators).
Page 50
In the morning OFF, in the evening ON, in the morning UP, in the evening DOWN Sun protection Sensor at front, sensor right, sensor left, maximum value (The sensor names can be edited and are also displayed in the LUXORplay app). LUXORliving system manual...
Page 51
Participation and operation in case of wind alarm can be set for each blinds function individually in room view. In the event of a wind alarm, the assigned drives travel upwards to the end position. During the active wind alarm, all operating commands will be ignored. LUXORliving system manual...
Page 52
LUXORplay app. If the hanging was moved to the corresponding position by using a button before the alarm, this position will be ignored. No response: The hanging remains in the position that was set when the alarm was activated. LUXORliving system manual...
Page 53
In the evening DOWN: This function can be used in connection with blinds functions and allows an automatic down travel (to the lower end position) if the brightness value falls below the set value. For each function, the brightness threshold and the delay times can be set individually. LUXORliving system manual...
Page 54
For each function, the position "height" and "slat" can be set in percentage values. The delay times are non-adjustable (exceeding: 3 minutes, falling below: 20 minutes). If the brightness threshold for the shading is fallen below after 20 minutes, the hanging will move up. LUXORliving system manual...
If possible, only one LUXORliving RF media coupler should be present in the system and installed centrally so that all LUXORliving RF devices are within reception range. To optimise the range, individual RF devices can be used as "repeaters", so even more distant RF devices can be reached.
Page 56
To read in another device, select "OK". By pressing "No" the reading will be ended. Now, the functions can be created and linked in the respective rooms as with conventional sensors/actuators. The addressing or assignment of the RF domain of the LUXORliving RF devices is not carried out until programming. LUXORliving system manual...
Page 57
- While the key is held, switch on the power again. After approx. 2 s the button can be released. The LED goes out. If a Master reset must be performed on the coupler, the button is not released until the reception LED lights up. LUXORliving system manual...
Page 58
It is therefore essential to know the topology of the devices and to use the "repeater" function in a targeted manner. The circles in the picture represent the field strength in the system. LUXORliving system manual...
Page 59
If a project contains devices with encrypted communication, a project password is required. This project password protects the keys for communication and must be entered when opening the project file. The password can be changed at any time under "Settings". Currently, only the RF components support encrypted communication. LUXORliving system manual...
Click on the "Program system" field and then on "Start". Here, you can also overwrite devices which have been installed, but not yet included in your project. This ensures that these devices do not disturb the functions included in the project. LUXORliving system manual...
Page 61
Before programming, the firmware version of the IP1 will be checked automatically. If a new version is available, the firmware of the IP1 will be updated automatically before programming (duration approx. 2 minutes). For this purpose, the Admin password has to be entered. After the update, programming is started. LUXORliving system manual...
Page 62
In order for the LUXORplay app to be able to access the programmed functions, this has to be prepared in the "System" menu. The project is thereby transferred from LUXORplug to the LUXORliving IP1 system control centre. Click on the "Prepare LUXORplay" field and start the data transmission to the system centre.
Page 63
Start-up with LUXORplug 5.4.2 Set interface Another function in the "System" menu allows the setting of the LUXORliving IP1 system control centre. Principally, the system control centre is automatically detected. If this is not the case, the IP address of the connected system control centre can be entered manually in this menu. You can read the IP address of the system control centre in the display.
Page 64
The recording can be started, stopped and saved. The recording can also run in the background when the Diagnosis window is exited. By selecting the "screen icon", the recording can also be displayed in a separate window. LUXORliving system manual...
Page 65
The project overview can be exported as a text file (.csv) for further processing or documentation. 5.4.3.3 Test The test page allows you to determine whether the safety functions take effect without exceeding a safety threshold. In this way, a response to wind, rain or frost can be simulated. LUXORliving system manual...
Operation with LUXORplay 6 Operation with LUXORplay With the free LUXORplay app, the LUXORliving smart home system can be operated simply and conveniently. There are also various additional functions. 6.1 Users and authorisations 6.1.1 Logging in as the administrator Open the LUXORplay app.
Page 67
Once a user has been created successfully, actions and access rights can be assigned to them in the next step. Afterwards, the individual users (e.g. family members) can connect to the system with their individual login details. LUXORliving system manual...
Page 68
In this window, the user can log in to the LUXORplay app using their username and password. There is the option of having the system remember the login details in this case too, so that they can then be used to log in to the app after it has been restarted automatically. LUXORliving system manual...
The scene can either be triggered in the LUXORplay app, or with a defined trigger, e.g. button. The scene can also be started with a time control (see "Entering switching times" chapter). List of participants LUXORliving system manual...
Page 70
LUXORplay (current dimming value, current position (height/slat), switching status). Using the pen, the state can be individually changed and automatically added to the scene. The participation in a scene can also be defined directly in the function/room. LUXORliving system manual...
You can configure functions or scenes to switch on at particular times. This involves creating switching times that trigger a function or scene at a particular point in time. If the time switch icon is activated in a function or scene, the switching times can be entered in a new window. LUXORliving system manual...
Page 72
Cancelling the dimming limit The dimming limit can be cancelled by deleting the limit or by changing over to "switching time". LUXORliving system manual...
Page 73
8:00 p.m.; this prevents the blinds from moving to the sun protection position as early as 8:00 a.m. Settings in "Automatic" > "Sun protection" or "Twilight" Automatic sun function and twilight are always activated by default. LUXORliving system manual...
Page 74
6.3.4 Presence simulation The presence simulation can be easily defined in the LUXORplay app and be activated when absent. The presence simulation in LUXORliving makes sure that for instance the lights are switched on and the blinds go down every evening.
Page 75
Initially, different profiles can be selected, which have predefined values for the settings of duration and repetition (only with the "Light/Switching" function). Light in common room: Less switchings with a longer duration (e.g. living room) Light in passage room: More frequent switchings with shorter duration (e.g. corridor) LUXORliving system manual...
Page 76
Activation only once a day, starts the simulation always at the same time. Case 2: With additional activation and after sunset, the simulation starts with the latest event. The condition sunset is only available if a LUXORliving M140 weather station is present in the system. Example 1 (e.g. summer months)
Page 77
Once you have set all the parameters as you want them, click "Activate holidays" on the previous screen to start the presence simulation. Each setting taking part in the simulation is identified with a small aeroplane icon in the room view. LUXORliving system manual...
You can use this setting to adjust the system control centre's date and time manually. Alternatively, you can activate synchronisation with the system time (if you are using a smartphone or tablet). Software info Information about the installed version, contact details, and terms and conditions. LUXORliving system manual...
Page 79
In the event of a malfunction in LUXORplay, so-called "logs" can be exported for diagnosis. In iOS and Android, the e-mail app opens, and you can send these logs directly to our hotline. In Windows, LUXORplay creates a folder C:\Documents\export_logs, where the encrypted diagnostic file is stored. LUXORliving system manual...
All LUXORliving functions can be controlled, and statuses monitored by remote access via Theben Cloud using the LUXORplay app. In order to use remote access via Theben Cloud, the user must first register on the website https://cloud.theben.de. Click on the "Register" button.
Page 81
LUXORliving – the Theben Cloud Fill in the registration form. Click on the field "Register now for free". Further configuration will take place in the LUXORplay app: Log in to the LUXORplay app as administrator. Note: You must be connected to your local network! ...
Page 82
LUXORliving – the Theben Cloud Authenticate with the credentials for Theben Cloud. System central IP1 will be automatically assigned to your cloud account. Your system central IP1 is now also displayed online at https://cloud.theben.de under Gateways in your cloud account.
Page 83
LUXORliving – the Theben Cloud Now you can log in with the LUXORplay app via the cloud. In the LUXORplay app, click on the "cloud symbol" and authenticate for the cloud with your access data. LUXORliving system manual...
In the user administration, additional users can be added, who can also access the system via Theben Cloud. If a new user (e.g. spouse or child) is added, this user can be marked as a "Theben Cloud user". The following information is entered for the new user:...
LUXORliving – the Theben Cloud 7.2 Cloud access for an existing user If users have already been created for local access, they can also be invited to Theben Cloud. In Settings > User Management, a "cloud invitation" will be sent to the desired user.
Page 86
Once the user has completed registration and login, he will now also be displayed under Users in your cloud account. Now, the new user can also connect to Theben Cloud on the LUXORliving system via the "cloud symbol". LUXORliving system manual...
Enter your login credentials (email and password) of the previously created Theben Cloud user account and click on "Login". Select the Theben system control centre which you want to link to the skill from the list of gateways.
Page 88
Only those scenes can be operated by voice which are also assigned to a scene trigger in the LUXORliving system, e.g. a push button. As an alternative to the scenes in LUXORliving, you can also individually set so-called routines in the Alexa app, which are then activated via a voice command.
Enter your login credentials (email and password) of the previously created Theben Cloud user account and click on "Login". Select the Theben system control centre which you want to link to the "action" from the list of gateways.
Page 90
Now, you have to add the detected devices. To do this, select the respective device and go to "Add". Select the room to which the device should be added. Done! You can now control your LUXORliving system by voice using our Theben LUXORliving action. 8.2.3 Examples The {device name} always refers to the name of the function you set in the LUXORplug configurator, or the one you have already customised in the Amazon Alexa app.
7. You have a user account for Home Connect Plus. 8.3.2 Integration To use your LUXORliving smart home system with Home Connect Plus, follow these steps: Install the Home Connect Plus app on the smartphone/tablet. Log in with the credentials for Home Connect Plus.
Page 92
Integration of personal assistants 8.3.3 Home Connect Plus triggers and actions of LUXORliving Triggers: • Switching ON/OFF • Scene is triggered • Temperature higher/lower • Wind alarm active/not active • Frost alarm active/not active • Rain active/not active Actions: •...
Enter your login credentials (email and password) of the previously created Theben Cloud user account and click on “Login”. Select the Theben system control centre you want to link to “IFTTT” from the list of gateways. Enter the user name (admin) and password of the Theben system control centre and click on “Login”.
Page 94
Action LUXORliving (LX) Turning off the garden irrigation LX weather station Switch off garden irrigation system if the LX weather station “Rain” = Yes (Theben) (e.g. Gardena) detects rain. Activate shading when a certain LX weather station Activate shading (Theben) outdoor temperature is exceeded.
Page 95
Trigger LX scene “Welcome when the smartphone logs into into WiFi (TP-Link) Home” (Theben) WiFi. Activate the “Leaving house” scene Geofencing Trigger central OFF (Theben) when the smartphone leaves the (smartphone IFTTT geofence. app) Receive notification when the LX LX weather station Receive push notification weather station reports rain.
Appendix 9 Appendix 9.1 Debug mode In debug mode, the connected group addresses are displayed for each function if the cursor is placed on it. LUXORliving system manual...
"Firmware". The process can be cancelled at any time with the "Cancel" button. The device then contains the latest installed software. CAUTION: A device update should only be carried out after consulting the Theben hotline. LUXORliving system manual...
10.1.2 How many devices can be integrated in one system? The system can be equipped with a maximum of 64 LUXORliving TP devices and a maximum of 64 LUXORliving RF devices, i.e. it includes system devices, sensors and actuators. A total of 15 media couplers can be used in the system.
Page 99
200 W per channel and the LUXORliving D1, 250 W (in RC mode, this also applies to LED load!). Generally, these output limits are sufficient. If an increase of the load is still required, the LUXORliving D2 can be extended with the DMB 1 T dimming booster (max. 2 x DMB 1 T per channel).
Page 100
10.1.10 How is room temperature control accomplished in the LUXORliving system? The room temperature is detected and set via room sensor LUXORliving R718 or the iON8. The current room temperature is also displayed in the LUXORplay app, where the setpoint can always be defined.
Check the router settings (DHCP must be activated). If "No BUS" appears on the permanent display of the IP1: Check the cable connection to the LUXORliving power unit. 10.2.2 What is the default password of the IP1 on delivery? The password is always "admin".
Page 102
CAUTION: If a master reset is performed, all settings will be deleted, including e.g. the project, scenes and switching times. A master reset or restart is performed directly on the LUXORliving IP1: Press the " " button on the device.
Page 103
FAQs concerning the LUXORliving webpage To make the parameter visible, click 5 times consecutively in the blue bar of the settings 10.2.8 Why are changed function or room names not accepted in LUXORplay when they are defined in LUXORplug? Changing function names or room designations is also possible from LUXORplay (pen function).
Need help?
Do you have a question about the LUXORliving and is the answer not in the manual?
Questions and answers