Deploy the EDA 8320 sensor
Published: 2024-06-24
This guide explains how to install the rack-mounted EDA 8320 sensor.
This installation enables you to run network performance monitoring, network detection and response,
and intrusion detection on a single sensor. By adding the IDS module, you can also upload and view IDS
detections.
Note: If you have enabled the IDS module on this sensor, and your ExtraHop system does not have
direct access to the Internet and access to ExtraHop Cloud Services, you will need to upload
IDS rules manually. For more information, see
through the REST API
Installation prerequisites
To install the sensor, your environment must meet the following requirements:
Sensor
1U of rack space and electrical connections for 2 x 800 W power supplies.
Management
One 10/100/1000 BASE-T network port or one 10G BASE-SR port for sensor management.
Monitoring (capture)
High performance interfaces: One to two network ports for connection to 25 GbE or 10 GbE sources
of packet data.
Management + monitoring interfaces: One to three network ports for connection to 1 GbE sources
of packet data.
Network Access
Ensure that administrators can access the Administration settings on the sensor over TCP port 443.
For more information about the interfaces on the ExtraHop system, see the
Rear panel ports
EDA 8320
1.
Power supply unit (PSU1) to connect the sensor to an AC power source
2.
Two 25 GbE-capable ports on two network adapters
3.
One RS-232 serial port to connect a console device
4.
Power supply unit (PSU2) to connect the sensor to an AC power source
Upload IDS rules to the ExtraHop system
.
©
2024ExtraHop Networks, Inc. All rights reserved.
ExtraHop Hardware FAQ
.

Advertisement

loading
Need help?

Need help?

Do you have a question about the EDA 8320 and is the answer not in the manual?

Questions and answers

Summary of Contents for ExtraHop EDA 8320

  • Page 1 By adding the IDS module, you can also upload and view IDS detections. Note: If you have enabled the IDS module on this sensor, and your ExtraHop system does not have direct access to the Internet and access to ExtraHop Cloud Services, you will need to upload IDS rules manually.
  • Page 2 Install the sensor in your data center with the included rack-mounting kit. The mounting kit supports most four-post racks with either round or square holes. Orient the hardware to ensure proper airflow. The cold air intake is through the front of the sensor. Deploy the EDA 8320 sensor 2...
  • Page 3: Management Ip Address Configuration

    Management IP address configuration DHCP is enabled by default on the ExtraHop system. When you power on the system, interface 1 attempts to acquire an IP address through DHCP. If successful, the IP address appears on the home screen of the LCD.
  • Page 4 8 data bits, no parity, 1 stop bit (8N1), and hardware flow control disabled. You can manually configure an IP address from the CLI. Establish a connection to the ExtraHop system. At the login prompt, type shell and then press ENTER.
  • Page 5: Configure The Sensor

    Before you begin Before you can configure the sensor, you must have already configured a management IP address. Log in to the Administration settings on the ExtraHop system through https://<extrahop- hostname-or-IP-address>/admin. The default login name is setup. The password is the system serial number that appears in the Info section of the LCD display and on the label on the back of the sensor.