ELI-S-25
MICRO INVERTER
Installation and Operation Instructions
ELI SERIES EMERGENCY LIGHTING INVERTERS
! IMPORTANT SAFEGUARDS !
READ AND FOLLOW ALL SAFETY INSTRUCTIONS
1. ELI-S-25: For use with non-dimming fluorescent, incandescent or LED fixtures up to 25VA. For use with
fluorescent and LED fixtures that utilize 0-10V dimming that are above 25VA, but this inverter will be limited to
25VA (including driver/ballast).
2. Make sure all connections are in accordance with the National Electrical Code and any local regulations.
3. To reduce the risk of electric shock, disconnect both normal and auxiliary power supplies and inverter
connector of the backup micro inverter before servicing.
4. This backup micro inverter is for field installation.
5. An AC power source (120 or 277 VAC, 60 Hz) ahead of any wall switch is required to provide battery charging
current.
6. Do not install near gas or electric heaters.
7. This product is for use in indoor or damp locations where the ambient temperature is 0°C to 50°C. Not suitable
for outdoor, wet, or hazardous locations.
8. This is a sealed unit. Integral battery is not replaceable. Replace entire unit when necessary.
9. The use of accessory equipment not recommended by the manufacturer may cause an unsafe condition.
10. Do not use this product for other than intended use.
11. Servicing should be performed by qualified service personnel.
12. Equipment should be mounted in locations and at heights where it will not be subjected to tampering by
unauthorized personnel.
13. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this
device may not cause harmful interference, and (2) this device must accept any interference that may cause
undesired operation.
14. This product must be grounded.
! IMPORTANT ! - PLEASE TAKE NOTE BEFORE THE INSTALLATION:
THIS PRODUCT CONTAINS A RECHARGEABLE LITHIUM-ION BATTERY.
THE BATTERY MUST BE RECYCLED OR DISPOSED OF PROPERLY.
Collierville, TN USA • Tech Support 888-263-4638 • Fax 901-853-5009 • www.bodine.com
SAVE THESE INSTRUCTIONS
Lithium Ion
4/17/2024
Bodine © 2024 Signify Holding. All rights reserved.
442296095481
WHEN USING ELECTRICAL EQUIPMENT, BASIC
SAFETY PRECAUTIONS SHOULD ALWAYS BE
FOLLOWED, INCLUDING THE FOLLOWING:
BC

Advertisement

Table of Contents

Troubleshooting

loading
Need help?

Need help?

Do you have a question about the ELI Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Bodine ELI Series

  • Page 1 Lithium Ion THIS PRODUCT CONTAINS A RECHARGEABLE LITHIUM-ION BATTERY. THE BATTERY MUST BE RECYCLED OR DISPOSED OF PROPERLY. 4/17/2024 Bodine © 2024 Signify Holding. All rights reserved. Collierville, TN USA • Tech Support 888-263-4638 • Fax 901-853-5009 • www.bodine.com 442296095481...
  • Page 2: Installation

    INSTALLATION NOTE: Make sure that the necessary branch circuit wiring is available. An unswitched source of power is required. The unswitched and switched power source must be fed from the same branch circuit. This product is suitable for field installation with suitable luminaires including LED, fluorescent, and incandescent luminaires with 0-10V dimming capability.
  • Page 3 INSTALLATION STEP 4 - APPLY AC POWER > After installation is complete, apply AC power. > At this point, power should be connected to both the AC ballast and the backup micro inverter, and the green Charging Indicator Light should illuminate indicating the battery is charging. >...
  • Page 4: Operation

    OPERATION During normal operation, AC power is supplied to the AC ballast/driver through the backup micro inverter and the inverter charges its internal battery. The backup micro inverter may be powered via 120 or 277VAC but will only output 120VAC 60Hz. When AC power fails, the backup micro inverter automatically switches to emergency mode, keeping the load illuminated for a minimum of 90 minutes.
  • Page 5: Troubleshooting

    TROUBLESHOOTING Trouble State or Error Corrective Action Indicator Light Status • The unit is operating correctly, and the internal battery is Green/ No Flashes None fully charged. • The Unit is charging. The main light is operating normally. • The Unit is running a self-diagnostic test. The Fixture Load Green / Slow None is operating in Emergency mode.
  • Page 6: Wiring Diagram

    WIRING DIAGRAM DIM+ OUT (VIOLET/WHITE) DIM+ IN (VIOLET) DIM- IN (PINK) DIM- OUT (PINK/WHITE) DRIVER LIGHT Micro NEUTRAL IN (WHITE) SOURCE Inverter NEUTRAL OUT (RED/WHITE) Unswitched HOT (RED) BALLAST Switched HOT IN (BLACK) HOT OUT (RED/BLACK) • Earth Ground • (RED) •...