Bodine ELI Series Installation And Operation Instruction Manual

Bodine ELI Series Installation And Operation Instruction Manual

Self-testing sinewave inverter

Advertisement

Quick Links

ELI-S-250 &
ELI-S-185 2-Hour
SELF-TESTING SINEWAVE INVERTER
Installation and Operation Instructions
ELI SERIES EMERGENCY LIGHTING INVERTERS
! IMPORTANT SAFEGUARDS !
READ AND FOLLOW ALL SAFETY INSTRUCTIONS
1. Do not use outdoors.
2. Do not let power supply cords touch hot surfaces.
3. This product is suitable for use in damp locations where the ambient temperature is 20ºC minimum, 30ºC maximum.
Product is not suitable for heated air outlets and wet or hazardous locations. DO NOT INSTALL NEAR GAS OR
ELECTRIC HEATERS.
4. Equipment should be mounted securely in locations and at heights where it will not be readily subjected to
tampering by unauthorized personnel.
5. The use of accessory equipment and replacement parts not recommended by the manufacturer may cause an unsafe
condition.
6. Do not use this equipment for other than its intended purpose.
7. The AC voltage rating of this equipment is 120 or 277 VAC. Do not connect equipment to any other voltage.
8. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and
(2) This device must accept any interference that may cause undesired operation.
Consumer Information :
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commer-
cial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance
with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential
area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
! IMPORTANT ! - PLEASE TAKE NOTE BEFORE THE INSTALLATION:
You must determine how the connected emergency lighting fixtures are to operate; normally-on (unswitched and
always energized), normally-off (only energized during a power failure), or switched on/off. Wire according to the
appropriate wiring diagram given below. Consult factory for special wiring diagrams.
Ensure that ALL combined/connected Emergency lighting loads OVER this product's maximum emergency output
rating (250 VA or 185 VA, depending on the model) are capable of being dimmed down to a power output of 10%
from an industry standard 0-10V source.
ELI-S-250 WILL ONLY deliver 250 VA and the ELI-S-185 WILL ONLY deliver 185 VA into the lighting load. This is
accomplished by automatically dimming the connected emergency lighting loads down to the products output power
rating.
Pb
Collierville, TN USA • Tech Support 888-263-4638 • Fax 901-853-5009 • www.bodine.com
SAVE THESE INSTRUCTIONS
THIS PRODUCT INCLUDES RECHARGEABLE LEAD-ACID BATTERIES.
THE BATTERIES MUST BE RECYCLED OR DISPOSED OF PROPERLY.
7/8/2022
Bodine © 2022 Signify Holding. All rights reserved.
442295564161
WHEN USING ELECTRICAL EQUIPMENT, BASIC SAFETY
PRECAUTIONS SHOULD ALWAYS BE FOLLOWED,
INCLUDING THE FOLLOWING:
BC

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ELI Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Bodine ELI Series

  • Page 1 THIS PRODUCT INCLUDES RECHARGEABLE LEAD-ACID BATTERIES. THE BATTERIES MUST BE RECYCLED OR DISPOSED OF PROPERLY. 7/8/2022 Bodine © 2022 Signify Holding. All rights reserved. Collierville, TN USA • Tech Support 888-263-4638 • Fax 901-853-5009 • www.bodine.com 442295564161...
  • Page 2 MODEL SPECIFIC OUTPUT RATINGS Output Input Emergency Output Max Connected Model Voltage Emergency Run Time Voltage Power AC Load* (Autoselect) ELI-S-250 120/277Vac 120/277Vac 250 VA 800 VA Minimum of 90 minutes ELI-S-185 120/277Vac 120/277Vac 185 VA 800 VA Minimum of 120 minutes * NOTE: AC Input Power to an LED or Fluorescent Driver/Ballast is always more than the output power.
  • Page 3 STEP #2 BATTERY INSTALLATION AND CABLE CONNECTION This product is provided with two sealed lead-acid batteries. Only the batteries supplied by the inverter manufacturer should be used. Install the batteries as shown, referring to Illustrations 2A and 2B. With the unit secured to the mounting surface, begin installation by sliding the batteries into the enclosure. Connect the battery cables using the supplied hardware.
  • Page 4 STEP #4 WIRING THE EMERGENCY LIGHTING INVERTER’S DIMMING CONNECTIONS (OPTIONAL) This product features an industry-standard 0-10V dimming voltage output. Existing area dimming controls can be wired through the product's dimming relay to allow for normal dimming by occupants of the area during Normal mode opera- tion.
  • Page 5 MAINTENANCE & TROUBLESHOOTING WARNING: Always turn off SW-1(first), then turn off AC power to the equipment inside the case before servicing. ! REFER ANY SERVICING TO QUALIFIED PERSONNEL ! Servicing should be performed only by qualified service technicians. Use only manufacturer supplied replacement parts.
  • Page 6 REPLACEMENT PARTS Accessories Replacement Batteries Model Installation Kit Battery Harnesses Fuse Part No. Quantity ELI-S-250 & 185 PRT00143 PRT00144 Littlefuse 0312030 PRT00141 1 Required Battery Maintenance: The batteries supplied with this equipment require no maintenance. However, the inverter should be tested periodically, and batteries replaced whenever they will no longer operate the connected fixtures for the rated run- time.
  • Page 7 Figure W2, shows an example of an alternate emergency lighting system in which the emergency luminaires ARE NOT dimmable. In this case, the total connected Emergency lighting load MUST BE LESS THAN or EQUAL to the Inverter's maximum output power. Non-DIMMABLE EMERGENCY LIGHTING SYSTEM TOTAL POWER ANY QUANTITY SUPPORTED...

This manual is also suitable for:

Eli-s-250Eli-s-185Eli-s-185-2hr

Table of Contents