STODDART GIORIK 700 Series Installation, Operation & Maintenance Manual

Hide thumbs Also See for GIORIK 700 Series:

Advertisement

Quick Links

INSTALLATION / OPERATION / MAINTENANCE
MANUAL
(READ ALL INSTRUCTIONS BEFORE USE)
700/900
FRYER
(Gas / Electric)
Models:
700 Series:
Gas: FG7207TT / FG7417PT / FG7817PT
Electric: FE7110TT / FE7117T / FE7207T / FE7210TT / FE7217T
900 Series:
Gas: FG9207TT / FG9421PT / FG9821PT
Electric: FE9121T / FE9207T / FE9221T
Revision: A - 07/04/2022 - 03

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the GIORIK 700 Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for STODDART GIORIK 700 Series

  • Page 1 INSTALLATION / OPERATION / MAINTENANCE MANUAL (READ ALL INSTRUCTIONS BEFORE USE) 700/900 FRYER (Gas / Electric) Models: 700 Series: Gas: FG7207TT / FG7417PT / FG7817PT Electric: FE7110TT / FE7117T / FE7207T / FE7210TT / FE7217T 900 Series: Gas: FG9207TT / FG9421PT / FG9821PT Electric: FE9121T / FE9207T / FE9221T Revision: A - 07/04/2022 - 03...
  • Page 2 Page Intentionally Left Blank Due to continuous product research and development, the information contained herein is subject to change without notice. www.stoddart.com.au www.stoddart.co.nz Page 1...
  • Page 3: Specification

    3.6 Electrical Connection - Electric Models ..25 3.6.1 Information 3.6.2 Wiring Due to continuous product research and development, the information contained herein is subject to change without notice. www.stoddart.com.au www.stoddart.co.nz Page 2...
  • Page 4 Giorik product in accordance with these instructions, will provide many years of reliable service. Stoddart is a wholly Australian owned company, which manufactures and/or distributes a comprehensive range of food service equipment for kitchens, food preparation and presentation. Stoddart products are manufactured and engineered to provide excellent results whilst offering value-for-money, ease-of-use and reliability.
  • Page 5: Warranty And Registration

    1.2.1 Warranty Period All Stoddart manufactured and distributed products are covered by Stoddart’s standard Australia and New Zealand Product Warranty (minimum 12 month on-site parts and labour, terms and conditions apply). Further to this standard warranty, certain products have access to an extended warranty.
  • Page 6: General Precautions

    The manufacturer declines any liability for damages to persons and/or things due to an improper/wrong and/or unreasonable use of the machine • Only specifi cally trained/qualifi ed Technicians (Stoddart, one of our service agents, or a similarly qualifi ed persons) should carry out any and all repairs, maintenance and services 1.3.1 General Warnings •...
  • Page 7 For further information on the recycling of this product, contact the local dealer/agent or the local body responsible for waste disposal Due to continuous product research and development, the information contained herein is subject to change without notice. www.stoddart.com.au www.stoddart.co.nz Page 6...
  • Page 8 1.0 kPa 2.65 kPa Total Nominal Gas Consumption 43.2 MJ/h 43.2 MJ/h 68.4 MJ/h 68.4 MJ/h 136.8 MJ/h 136.8 MJ/h Due to continuous product research and development, the information contained herein is subject to change without notice. www.stoddart.com.au www.stoddart.co.nz Page 7...
  • Page 9: Rating Plate

    Fully Open Main Burner - 900 - FG9207TT 43.2 MJ/h 10mm Main Burner - 900 - FG9421PT 68.4 MJ/h Fully Open Imported by: STODDART Main Burner - 900 - FG9821PT 136.8 MJ/h Fully Open www.stoddart.com.au Pilot Burner - 700/900 REG.
  • Page 10 720mm Overall Width 800mm 3Ø + N + E Electrical Connection 415VAC / 50Hz / 21.6kW Legend Electrical Connection Due to continuous product research and development, the information contained herein is subject to change without notice. www.stoddart.com.au www.stoddart.co.nz Page 9...
  • Page 11 720mm Overall Width 400mm 3Ø + N + E Electrical Connection 415VAC / 50Hz / 10.8kW Legend Electrical Connection Due to continuous product research and development, the information contained herein is subject to change without notice. www.stoddart.com.au www.stoddart.co.nz Page 10...
  • Page 12 1.0 kPa 2.65 kPa Total Nominal Gas Consumption 43.2 MJ/h 43.2 MJ/h Legend Gas inlet (1/2” BSP) Electrical Connection Due to continuous product research and development, the information contained herein is subject to change without notice. www.stoddart.com.au www.stoddart.co.nz Page 11...
  • Page 13 1.0 kPa 2.65 kPa Total Nominal Gas Consumption 115.2 MJ/h 115.2 MJ/h Legend Gas inlet (1/2” BSP) Electrical Connection Due to continuous product research and development, the information contained herein is subject to change without notice. www.stoddart.com.au www.stoddart.co.nz Page 12...
  • Page 14 920mm Overall Width 400mm 3Ø + N + E Electrical Connection 415VAC / 50Hz / 21kW Legend Electrical Connection Due to continuous product research and development, the information contained herein is subject to change without notice. www.stoddart.com.au www.stoddart.co.nz Page 13...
  • Page 15 1.0 kPa 2.65 kPa Total Nominal Gas Consumption 43.2 MJ/h 43.2 MJ/h Legend Gas inlet (1/2” BSP) Electrical Connection Due to continuous product research and development, the information contained herein is subject to change without notice. www.stoddart.com.au www.stoddart.co.nz Page 14...
  • Page 16 1.0 kPa 2.65 kPa Total Nominal Gas Consumption 136.8 MJ/h 136.8 MJ/h Legend Gas inlet (1/2” BSP) Electrical Connection Due to continuous product research and development, the information contained herein is subject to change without notice. www.stoddart.com.au www.stoddart.co.nz Page 15...
  • Page 17: Installation

    The unit must be installed under an extraction canopy that meets AS 1668.2-2012 and in accordance with all local council regulations. Note: Combustible materials must not be used overhead/above the unit. Due to continuous product research and development, the information contained herein is subject to change without notice. www.stoddart.com.au www.stoddart.co.nz Page 16...
  • Page 18 • On the side of the units to be connected, using long nose plate and retaining screws pliers remove the fill caps Due to continuous product research and development, the information contained herein is subject to change without notice. www.stoddart.com.au www.stoddart.co.nz Page 17...
  • Page 19 • Using the provided bolts and nuts connect the units at the front and rear • Re-install the back cover plate, the front fascia and the control dials Due to continuous product research and development, the information contained herein is subject to change without notice. www.stoddart.com.au www.stoddart.co.nz Page 18...
  • Page 20 3.3.1 Connecting the gas If the unit has Stoddart approved factory fitted castors, then the unit must be connected with a flexible gas hose and restraining kit (not supplied by Stoddart). Flexible gas hose connection and Hose assemblies for use with cooking appliances shall be certified as conforming to AS/NZS 1869 and be Class B or Class D.
  • Page 21: Gas Pressure Check

    If the gas operating pressure is incorrect, adjust pressure regulator installed on the incoming gas supply to the unit. The operating pressure is measured at the pressure inlet test point (fig 5). Inlet Test Point Fig.5. Due to continuous product research and development, the information contained herein is subject to change without notice. www.stoddart.com.au www.stoddart.co.nz Page 20...
  • Page 22 If the unit is to be connected to a different type of gas than that for which it has been prepared, the nozzles must be replaced. Please contact Stoddart for the approved Gas conversion Kit and settings. 3.4.1 Replacing the Main Burner Nozzle The fixed primary air is properly regulated if flame stability is ensured (if there are no breaks in the flame with the burner cold and no flashback when the burner is hot).
  • Page 23 When conversion has been completed for the relevant Gas Type, it is MANDATORY to edit the Rating Plate, with the new Gas Specification. Once the Gas conversion has been completed, the unit must be leak tested. Due to continuous product research and development, the information contained herein is subject to change without notice. www.stoddart.com.au www.stoddart.co.nz Page 22...
  • Page 24 If the unit is to be connected to a different type of gas than that for which it has been prepared, the nozzles must be replaced. Please contact Stoddart for the approved Gas conversion Kit and settings. 3.5.1 Replacing the Main Burner Nozzle The fixed primary air is properly regulated if flame stability is ensured (if there are no breaks in the flame with the burner cold and no flashback when the burner is hot).
  • Page 25 When conversion has been completed for the relevant Gas Type, it is MANDATORY to edit the Rating Plate, with the new Gas Specification. Once the Gas conversion has been completed, the unit must be leak tested. Due to continuous product research and development, the information contained herein is subject to change without notice. www.stoddart.com.au www.stoddart.co.nz Page 24...
  • Page 26 DO NOT pass the power cable near or allow it to come into contact with the rear of the appliance and/or flue of the cooker Due to continuous product research and development, the information contained herein is subject to change without notice. www.stoddart.com.au www.stoddart.co.nz Page 25...
  • Page 27: Operation

    To turn completely off, turn both dials to the off position Due to continuous product research and development, the information contained herein is subject to change without notice. www.stoddart.com.au www.stoddart.co.nz Page 26...
  • Page 28: Electric Controls

    To turn the appliance off, turn the thermostat dial to the off position Empty the pasta cooker by opening the waste gate Due to continuous product research and development, the information contained herein is subject to change without notice. www.stoddart.com.au www.stoddart.co.nz Page 27...
  • Page 29: Cleaning And Maintenance

    FOOD SAFE Due to continuous product research and development, the information contained herein is subject to change without notice. www.stoddart.com.au www.stoddart.co.nz Page 28...
  • Page 30 Using a clean sanitised cloth, thoroughly wipe the stainless steel and metal parts dry. Do NOT let water pool on the unit. Check crevices and folds Due to continuous product research and development, the information contained herein is subject to change without notice. www.stoddart.com.au www.stoddart.co.nz Page 29...
  • Page 31: Periodic Maintenance

    Damaged parts must be replaced, contact the Stoddart service department 5.2.3 Troubleshooting • If any faults/issues occur with the unit, follow the below troubleshooting procedures • If the troubleshooting procedures do not correct the problem, contact the Stoddart Service Department Problem Possible Causes Possible Corrective Action GAS MODELS Check the Gas Valve is fully open.
  • Page 32 Australia Service / Spare Parts Sales Tel: 1300 307 289 Tel: 1300 79 1954 Email: service@stoddart.com.au Email: sales@stoddart.com.au Email: spares@stoddart.com.au Service Request www.stoddart.com.au Australian Business Number: 16009690251 New Zealand Service / Spare Parts Sales Tel: 0800 935 714 Tel: 0800 79 1954 Email: service@stoddart.co.nz...

Table of Contents