  • Page 1 User’s manual 15/07/2024...
  • Page 2: Table Of Contents

    TABLE OF CONTENTS GENERAL INSTALLATION INSTRUCTIONS ......4 General Notes ................. 4 Making the installation ..............4 DESCRIPTION .................. 5 Features ....................6 LED ....................... 7 Hardware description ................8 INSTALLATION ................9 Inserting the SIM card ................9 Connecting the antenna................9 Connection to the telephone line............
  • Page 3 SIGNALS ..................33 Tones .................... 33 Call signals ................... 34 LED ....................34 GSM signal indicator LED (GREEN) ..........34 Status indicator LED (RED) ..............35 Line status indicator LED (WHITE) ............ 35 Power supply status indicator LED (BLUE) ........36 TROUBLE SHOOTING GUIDE .............
  • Page 4: General Installation Instructions

    • The product must be EXCLUSIVELY used for the purpose it was designed for. Esse-ti shall not be responsible for damages arising from improper use. • The product has been designed in compliance with the regulations in force and must be installed in systems that comply with the provisions of law.
  • Page 5: Description

    DESCRIPTION GSM500 GD BASIC/S GSM500 GD BASIC/S is a gateway that, connected to a fixed telephone or to the PSTN input terminals of a PABX or autodialer, allows you to make and receive calls over the GSM network. For correct operation, a GSM SIM card is required.
  • Page 6: Features

    Features • Local programming via telephone (DTMF tones) • Remote programming via SMS • Reading of programming codes via SMS • Display of caller identification • Automatic country setting • CLIP / CLIR • Roaming setting • SIM card expiration control •...
  • Page 7: Led

    • External adapter (230 Vac 50 Hz input; 12 Vdc 500 mA output; CE mark; on models: GD/S) The gateway is equipped with 4 visible LEDs. LEDs flashing is described at chapter “Signals” (see page 34). Green LED: GSM signal indicator LED Red LED: Device status indicator LED White LED: Line status indicator LED Blue LED: Power supply status indicator LED...
  • Page 8: Hardware Description

    Hardware description Remove the cover. ➢ ANTENNA cable connector SIM CARD housing LED indicating signal strength (green), LED indicating device operation status (red), LED indicating line status (white) and LED indicating power supply status (blue) Telephone line output (RJ11 connector) for telephone set connection or autodialer/PABX analogue line connection 230 Vac external adapter input Telephone line output (terminal block) for telephone set connection or...
  • Page 9: Installation

    INSTALLATION Inserting the SIM card Before inserting or replacing the SIM card, always make sure that the gateway has been disconnected from the mains and battery and that no electrostatic discharge is present in order to avoid damaging it. Take all necessary measures to avoid electrostatic discharge. Slide the SIM card housing cover upwards until it unblocks and lift ➢...
  • Page 10: Connection To The Telephone Line

    Position the antenna with magnetic base so that any metal ➢ surfaces do not block the signal. Connection to the telephone line Connect the gateway to a standard telephone or to the PSTN input ➢ terminals of a PABX or autodialer via the RJ-11 connector (D in the picture at page 8).
  • Page 11: Connection To The Power Supply

    Connection to the power supply Power supply via 230 Vac / 12 Vdc external adapter Connect the external adapter to the specific input (E in the picture ➢ at page 8). Connect the backup batteries (if present) to the dedicated input (H ➢...
  • Page 12: Turning The Gateway On

    Turning the gateway on Power-up the gateway. ➢ Wait 30 seconds after power-up to give time for the gateway to ➢ register correctly with the GSM network. Make sure the red LED (device status) flashes once per second as ➢ shown in chapter “Signals”...
  • Page 13: Gateway Mounting Operations

    Gateway mounting operations Check the GSM signal strength through the green indicator LED ➢ (see chapter “Signals”, page 34) and identify an area where the signal is strong enough. Note: the signal strength may vary according to the network provider. Drill two holes with 5 mm diameter on the wall at a distance of 50 ➢...
  • Page 14: Installation Recommendations

    Installation recommendations • The gateway must be installed in a location where the radio signal allows for using network. • It is advisable to leave plenty of space around the gateway for maintenance operations. • Do not install the gateway outdoors, since it lacks protection against weather conditions that can damage the gateway (water, humidity, etc.).
  • Page 15: Programming

    PROGRAMMING Programming can be carried out locally via a multi-frequency telephone or remotely via SMS. ROGRAMMING BY TELEPHONE Connect a standard telephone to the gateway via the RJ-11 ➢ connector (D in the picture at page 8) or using the TEL terminals (F in the picture at page 8).
  • Page 16 COUNTRY SETTING Default: automatic country setting X: option, from 1 to 2 1= mobile network line tones 2= line tones generated by GSM500 LINE TONES **2X# (recommended for autodialers or other devices effecting tone detection over the line) INTER-DIGIT X: seconds, from 1 to 9;...
  • Page 17 NOTIFICATIONS ON E-STANT WEB Default: notifications disabled e-stant web Instructions to use can be downloaded at the following link: http://webshare.esse-ti.it/guide.zip X…X: telephone number appointed for SMS notifications of SIM card expiration, battery, **40*X…X*X…X# external power failure/restore, mobile NOTIFICATION network restore and for SMS reading SIM...
  • Page 18 PROGRAMMING BY TELEPHONE Enabling **53*X…X# X…X: days before SIM expiration, from 1 to SIM CARD EXPIRATION **53*0# Disabling CHECK Default: check disabled X: option, from 0 to 1 **5X# 0= check enabled 1= check disabled X: option, from 0 to 7 0= 7 h 1= 6 h e 30’...
  • Page 19 PROGRAMMING BY TELEPHONE X…X: telephone number appointed for **72*X…X*X…X# periodic test SMS or calls **72# Deleting telephone number X: periodic test mode, from 0 to 1 **73*X# 0= CLI call 1= SMS XX: frequency, from 1 to 99 1-10: days **74*XX# 11-99: hours PERIODIC TEST...
  • Page 20 PROGRAMMING BY TELEPHONE ENTERING NUMBER TO CALL **26*X…X*Y*Z… X…X: programming password Y: table position, from 1 to 6 Z*Z…Z# Z…Z: telephone number DELETING NUMBER TO CALL **26*X…X*Y# X…X: programming password Y: table position, from 1 to 6 DELETING ALL NUMBERS TO CALL AUTOMATIC **26*X…X*# X…X: programming password...
  • Page 21: Sim Card Expiration Check

    PROGRAMMING BY TELEPHONE Resetting the gateway does not modify its RESET **98# programming profile SIM card expiration check If the SIM card expiration check is enabled, when the preset days have passed, a notification SMS is sent with the following text message: “SIM expiring”.
  • Page 22: External Power Failure Control

    External power failure control If the control on external power failure is enabled, the gateway constantly controls the external power supply (230 Vac or 12 Vdc). If the external power failure lasts longer than the preset time interval, a notification SMS is sent with the following text message: “External power failure”.
  • Page 23: Automatic Converter Of Selected Telephone Number

    Automatic converter of selected telephone number If the function is enabled the gateway, instead of calling the telephone number dialed from the connected telephone (autodialer or other telephone device), forwards the call to a previously set number. It is possible to pre-set up to 6 telephone numbers to call, each of which can be combined, through programming and / or automatic learning procedure, a dialed number.
  • Page 24 Matching telephone numbers automatically Enter the number to be called in a table location using ➢ programming code 26. Enter the dialed number, to be associated, in the same table ➢ location using programming code 25. Automatic learning procedure The auto-learning procedure allows to match automatically each preset number with the numbers dialed by the connected telephone (autodialer or other telephone device) with the gateway.
  • Page 25: Programming Via Sms

    ROGRAMMING VIA Programming via SMS is possible by any mobile phone or other device supporting SMS. In case the administrator number has been previously set, programming via SMS is only allowed from such telephone number. An SMS notifying that programming has been completed will be sent back by the gateway to the same telephone number that forwarded the programming SMS.
  • Page 26 Programming Code (x..x) Enabling CLIP 7*1*DDMMYY*HHMM Disabling CLIP Reading CLIP status CLIR permanent setting Reading CLIR permanent status CLIR temporary activation CLIR temporary deactivation Enabling roaming service Disabling roaming service 5*0*XXXY…Y Reading roaming service status e-stant web Enabling notifications on 02*1 e-stant web Disabling notifications on...
  • Page 27 Programming Code (x..x) Periodic test frequency 74*XX Reading periodic test frequency Time of periodic test 75*HHMM Reading time of periodic test Duration of CLI call 76*XX Reading duration of CLI call Enabling periodic test 77*1 Disabling periodic test 77*0 Forcing periodic test 77*2 Reading periodic test status Entering preset number...
  • Page 28: Notification Message Format

    Example: it is required to enable battery check and to set the telephone number for notifications. Outgoing message text: ET-IG5*0#50#40*X..X*X…X# Notification message format The format of the message notifying the user or the administrator who previously sent out a programming SMS, is the same as the programming message format.
  • Page 29: Services

    SERVICES NCOMING CALLS Allows you to answer incoming calls. Upon receiving a phone call, the LED indicating the line status (white) will blink shortly 4 times every 4 seconds as described at chapter “Signals” (see page 35) and the telephone will be ringing. Pick up the handset to answer the call.
  • Page 30: Measuring The Signal Level

    EASURING THE SIGNAL LEVEL This procedure allows you to check the GSM signal level through your telephone. Lift the handset and dial **30#. ➢ Wait for the signal reading. ➢ The gateway will send a number of short tones corresponding to the signal level: Tones Quality...
  • Page 31: Reading The Days Missing To Sim Card Expiration

    EADING THE DAYS MISSING TO CARD EXPIRATION This procedure allows you to check how many days until the SIM card expiration. Lift the handset and dial **54#. ➢ After the confirmation tone hang up. ➢ After receiving the request, the gateway will send an SMS to the number programmed to be alerted.
  • Page 32: Reading Advanced Device And Radio Cell Parameters

    ET-IG5*xxx#90# where: ET-IG5 programming string start *xxx# password string (default xxx = 0) GSM500 will send one or two SMS to the number that sent the request with the following data: String Meaning (the values shown are for illustrative purposes)
  • Page 33: Signals

    SIGNALS ONES Dialling It indicates that the gateway is ready for dialing. Dissuasion It indicates that t he gateway has not properly registered with the 4G delay in dialling or the end of conversation or LTE/UMTS/GSM provider or a an access to services not permitted. Busy It indicates that the called party is busy.
  • Page 34: Call Signals

    It indicates good signal level. It indicates high signal level. It indicates no signal. ALL SIGNALS It indicates an incoming call. GSM signal indicator LED (GREEN) It indicates no signal. It indicates low signal level. It indicates medium signal level. It indicates good signal level.
  • Page 35: Status Indicator Led (Red)

    It indicates the SIM card is protected by the PUK code. Status indicator LED (RED) It may indicate that the gateway has not been correctly registered with the network, the SIM card is protected by the PIN code or other problems. It indicates the gateway is correctly registered to the network.
  • Page 36: Power Supply Status Indicator Led (Blue)

    Power supply status indicator LED (BLUE) It indicates that the external power supply is connected and the battery guarantees more than 7-hour operation in idle state. It indicates that the external power supply is connected and the battery guarantees up to 7-hour operation in idle state. It indicates that the external power supply is connected and the battery guarantees 2-hour operation in idle state.
  • Page 37: Trouble Shooting Guide

    The autodialer The autodialer performs Set line tone generation by connected to gateway a tone detection over the GSM500 (see programming does not succeed in telephone line “Line tones” option 2 ) forwarding a call Page 37...
  • Page 38: Eu Declaration Of Conformity

    EU DECLARATION OF CONFORMITY Hereby, Esse-ti S.r.l. declares that the equipment type GSM500 GD is in compliance with Directive 2014/53/EU. The full text of the EU declaration of conformity is available from the following Internet address: https://www.esse-ti.it/en/dichiarazioni-di-conformita Page 38...