Download Print this page
Rice Lake iQUBE2 Quick Start Manual
Rice Lake iQUBE2 Quick Start Manual

Rice Lake iQUBE2 Quick Start Manual

Junction box
Hide thumbs Also See for iQUBE2:

Advertisement

Quick Links

2
iQUBE
® Junction Box/920i
Quick-Start Guide
This document will guide you through a typical iQUBE
truck scale is being used with two iQUBE
NOTE: Load cells or simulators must be connected before following the instructions listed in this document. RS-422 and
RS-485 are used interchangeably. TEDS is not supported.
Configuration using 920i
Establish a Connection
1. Connect the iQUBE
NOTE: RS-422 is recommended over RS-232 due to the 115,200 baud rate of the iQUBE
of 10 feet and RS-422 has a maximum distance of 1000 feet at this high baud rate.
2. The table below shows connections needed for RS-422 communications between a host 920i and the iQUBE
Two-wire half duplex is available on Port 4 of the 920i.
3. Ensure S2 dip switches on the iQUBE
location.
NOTE: If a change is made to switch position, cycle power on the iQUBE
position is only read on power-up. Once power has been re-applied, place the SW1 in the OFF position.
July 16, 2024
2
to 920i installation with the recommended settings. It assumes an 8-cell
2
CPU boards.
2
and the 920i using an RS-422 connection.
920i Board
J10 Connector (Port 4)
RS-422 Signal
GND
RS-422 A
RS-422 B
Table 1. 2-Wire RS-422 Connections for 920i Host
2
CPU board are set to 485 (1,2 both set to OFF). See
4 3 2 1
1
J12
S1
M/S PORT
1
J6
POWER SUPPLY
CONNECTOR
SW1
CONFIG SWITCH
+ S I G
– S I G
J1
+ E X C
– E X C
+ T D
– T D
+ S I G
– S I G
J2
+ E X C
– E X C
+ T D
– T D
Figure 1. iQUBE
2
iQUBE
J7 Connector
Pin
Pin
RS-422 Signal
1
1
GND1
5
4
RS-485 A
6
5
RS-485 B
2
while SW1 is switched to CFG, as the switch
6 5 4 3 2 1
1
1
J7
J5
SERIAL PORT 1
DIGITAL I/O
R T S
D T R
J14
485
232
R x D
S2
T x D
G N D 1
HDPLX
FDPLX
G N D
T M S
J8
T D I
T D O
T C K
G N D
+ 3 . 3
J10
– T D
+ T D
J3
– E X C
+ E X C
– S I G
+ S I G
– T D
+ T D
J4
– E X C
+ E X C
J9
HB1
– S I G
+ S I G
2
CPU Board
2
, RS-232 has a maximum distance
2
Figure 1
for S2 dip switch
PN 119611 Rev B
.

Advertisement

loading
Need help?

Need help?

Do you have a question about the iQUBE2 and is the answer not in the manual?

Questions and answers

Summary of Contents for Rice Lake iQUBE2

  • Page 1 iQUBE ® Junction Box/920i Quick-Start Guide This document will guide you through a typical iQUBE to 920i installation with the recommended settings. It assumes an 8-cell truck scale is being used with two iQUBE CPU boards. NOTE: Load cells or simulators must be connected before following the instructions listed in this document. RS-422 and RS-485 are used interchangeably.
  • Page 2 Junction Box/920i Quick-Start Guide RS-485 2-Wire RS-485 4-Wire J7 Pin RS-232 Signal Signal Signal GND1 GND1 GND1 — — — — — — — Table 2. J7 (Port 1) Pin Assignments J12 Pin Primary iQUBE Secondary iQUBE GND2 GND2...
  • Page 3 PROGIN PORTTYPE UPDATE CONFIG COMM SEL PORTTYPE DIGIO COMM BOARDS CELLS SCALES iQube Boards Number of iQube2 boards on port Manual Save and Auto Assign Assign Exit Figure 5. BOARDS Parameter © Rice Lake Weighing Systems ● All Rights Reserved...
  • Page 4 Junction Box/920i Quick-Start Guide 4. Press and release the setup button (S1) on secondary board #1. This makes cells 5-8 available to the system and registers its serial number with the primary board. The lights on the board will stop blinking.
  • Page 5 CELLS 1 – 4 Primary iQUBE² CELLS 5 – 8 CELLS 9 – 12 CELLS 13 – 16 Secondary Secondary Secondary iQUBE² #1 iQUBE² #2 iQUBE² #3 Figure 8. Primary-to-Secondary Communications Wiring © Rice Lake Weighing Systems ● All Rights Reserved...
  • Page 6 © Rice Lake Weighing Systems Content subject to change without notice. 230 W. Coleman St. • Rice Lake, WI 54868 • USA USA: 800-472-6703 • International: +1-715-234-9171 July 16, 2024 PN 119611 Rev B www.ricelake.com...

This manual is also suitable for:

920i