  • Page 1 Instructions for use Non-distensible Operating Laryngoscopes and Video Laryngoscopes...
  • Page 2 01-2022 Copyright © All product illustrations, product descriptions, and texts are the intellectual property of KARL STORZ SE & Co. KG. Their use and reproduction by third parties require the express approval of KARL STORZ SE & Co. KG. All rights reserved.
  • Page 3: Table Of Contents

    Table of contents Table of contents 1 General information  ........................1.1 Read the instructions for use ................... 1.2 Read the instructions for use of compatible products  ............ 1.3 Scope  ..........................1.4 General signs and symbols  ..................... 2 Normal use  ..........................2.1 Intended use ........................2.2 Indications ...
  • Page 4: General Information

    Read the reprocessing instructions of the compatible products carefully and follow all the safety notes and warnings. 1.3 Scope This instruction manual is valid for: Product Item number Laryngoscope 8574B, 8574C, 8574D, 8574E, 8574F, 8574G, 8576C, 8576CC, 8576D, 8576E, 8574N, 8590JA, 8661CN, 8661DN, 8661EN BENJAMIN Laryngoscope 8574JP DEDO Laryngoscope 8890A...
  • Page 5: General Signs And Symbols

    General information Product Item number BENJAMIN Operating Laryngoscope 8574J Operating Laryngoscope for Children 8574JB, 8590KL, 8587KK Operating Laryngoscope for Infants 8587P, 8590L, 8590LL Operating Laryngoscope & Subglottiscope 8574SL Video Laryngoscope 8590JV KANTOR-BERCI Video Laryngoscope 8590TV Laryngoscope Handle 8580H 1.4 General signs and symbols The signs and symbols used in this document have the following meaning: Practical tip This sign refers to useful and important information.
  • Page 6: Normal Use

    Normal use 2 Normal use 2.1 Intended use Laryngo-pharyngoscopes and operating laryngoscopes Laryngo-pharyngoscopes / operating laryngoscopes are used for examining and performing surgical procedures in the laryngeal region, both conventionally with microsurgical instruments and with lasers. Laryngo-pharyngoscopes / operating laryngoscopes are designed for short- term use in surgically invasive procedures.
  • Page 7: Safety

    Safety 3 Safety 3.1 Serious incidents A ‘serious incident’ includes incidents which, directly or indirectly, had, could have had or could have any of the following consequences: – Death of a patient, user, or another person – Temporary or permanent serious deterioration in the medical condition of a patient, user, or another person –...
  • Page 8: Product Description

    Product description 4 Product description 4.1 Product overview Operating laryngoscope and video laryngoscope with accessories Video laryngoscope Fiber optic light carrier Fiber optic light carrier (for video laryn- Injection cannula goscopes) Prismatic light deflector Suction tube to remove vapor Extension 10 Telescope protective sheath (for video laryngoscopes) Chest support...
  • Page 9 Product description Combination of operating laryngoscopes with prismatic light deflectors Operating Prismatic laryngoscope light deflector 10101FA 10101JA 10101JUA 8574B 8574C 8574D 8574E 8574G 8576C 8576CC 8576D 8576E These operating laryngoscopes can be combined with the chest supports (8574KT, 8574KW) if the prismatic light deflector (10101FA) is not being used.
  • Page 10 Product description Operating Fiber optic Clip for illu- Chest support laryngo- light carrier mination scope 497AC 8574KT 8575K 8575KT 8574KW 8575KC 8575KW 8576A 8576B 8580B 8580BL 8582B 8582BL 8583A 8583AL 8583B 8583BL 8587A 8587GF 8587AA 8587GF 8587KK 8587GF 8587N 8587PF 8587P 8587PF 8589B...
  • Page 11 Product description Operating Fiber optic Clip for illu- Chest support laryngo- light carrier mination scope 497AC 8574KT 8575K 8575KT 8574KW 8575KC 8575KW 8661DN 8661EN 8890A 8574LG The chest supports (8575K, 8575KC) can be combined with the extension for the chest support (8575V).
  • Page 12: Ambient Conditions

    Product description Operating Injection cannula Suction tube laryngo- to remove 8574GY 8574GZ 8587K 8590KC scope vapor 8590JL 8590M 8590K 8590N 8590KL 8574LN 8590L 8590N 8590LL 8574JK 8661CN 8661M 8661N with 8661P 8661DN 8661M 8661N with 8661P 8661EN 8661M 8661N with 8661P 8890A 8574LN...
  • Page 13: Symbols Employed

    Product description 4.4 Symbols employed 4.4.1 Symbols on the packaging Symbol Meaning Manufacturer Date of manufacture Medical device Article no. Batch code Number of products in the product packaging Unique Device Identifier Consult the printed or electronic instructions for use Unsterile Federal (USA) law restricts this device to sale by or on the order of a physician.
  • Page 14: Preparation

    Preparation 5 Preparation 5.1 Unpacking the product Carefully remove the product and accessories from the packaging. Check the delivery for missing items and any possible damage. In the case of damage, hidden defects, and short deliveries, document their nature and extent and contact the manufacturer or supplier immediately.
  • Page 15 Preparation  Example of a video laryngoscope Instructions for use • Non-distensible Operating Laryngoscopes and Video Laryngoscopes • MMG181_EN_V2.0_01-2022_IFU_CE-MDR...
  • Page 16: Disassembly

    Disassembly 6 Disassembly 6.1 Disassembling the product Remove the fixture for the accessories. Detach the accessories from the product. Instructions for use • Non-distensible Operating Laryngoscopes and Video Laryngoscopes • MMG181_EN_V2.0_01-2022_IFU_CE-MDR...
  • Page 17: Maintenance, Servicing, Repairs, And Disposal

    Maintenance, servicing, repairs, and disposal 7 Maintenance, servicing, repairs, and disposal 7.1 Maintaining the product If they are not described in more detail here, maintenance activities may only be performed by KARL STORZ or by a company authorized by KARL STORZ. 7.2 Repairing the product Repair work may only be performed by KARL STORZ or by a company authorized by KARL STORZ.
  • Page 18: Accessories And Spare Parts

    Accessories and spare parts 8 Accessories and spare parts 8.1 Recommended accessories Prismatic light deflectors Item Order no. Prismatic Light Deflector 10101FA Prismatic Light Deflector 10101JA Prismatic Light Deflector, Autoclavable 10101JUA Clips for illumination Item Order no. Clip for Illumination, for Proximal Illumination 497AC Fiber optic light carriers Item...
  • Page 19 Accessories and spare parts Telescopes Item Order no. HOPKINS Telescope 15°, 4 mm, 17 cm 8575AV HOPKINS Telescope 0°, 4 mm, 18 cm 7230AA HOPKINS Telescope 30°, 4 mm, 18 cm 7230BA HOPKINS Telescope 70°, 4 mm, 18 cm 7230CA HOPKINS Telescope 90°, 4 mm, 18 cm 7230DA HOPKINS Telescope 120°, 4 mm, 18 cm 7230EA HOPKINS Telescope 45°, 4 mm, 18 cm 7230FA...
  • Page 20 Accessories and spare parts Chest supports Item Order no. Laryngoscope Holder for prox. ped. laryn. 8574KT BENJAMIN-PARSONS Laryngoscope Holder for Children 8574KW Laryngoscope Holder and Chest Support 8575K BENJAMIN-PARSONS Laryngoscope Holder 8575KC LEWY Chest Support, Autoclavable 8575KT LEWY Chest Support, Autoclavable 8575KW Accessories Item...
  • Page 21: Subsidiaries

    E-mail: pisarna@karlstorz.si Phone: +54 11 4718 0919, Fax: +54 11 4718 2773 E-mail: info@karlstorz.com.ar KARL STORZ Polska Sp. z o.o. ul. Bojkowska 47, 44-100 Gliwice, Poland KARL STORZ Endoskopi Norge AS Phone: +48 32 706 13 00, Fax: +48 32 706 13 07 Stamveien1, 1483 Hagan, Norway E-mail: info-pl@karlstorz.com...
  • Page 22 KARL STORZ Endoscopy (South Africa) (Pty) Ltd. P.O. 6061, Roggebaai, 8012 Cape Town, South Africa KARL STORZ SE & Co. KG Representative Office Indonesia Phone: +27 21 417 2600, Fax: +27 21 421 5103 Sinarmas MSIG Tower Level 37, Jl. Jend. Surdirman No. Kav. 21, South E-mail: info@karlstorz.co.za...
  • Page 23 Subsidiaries Instructions for use • Non-distensible Operating Laryngoscopes and Video Laryngoscopes • MMG181_EN_V2.0_01-2022_IFU_CE-MDR...
  • Page 24 KARL STORZ SE & Co. KG Dr.-Karl-Storz-Straße 34 78532 Tuttlingen Postfach 230 78503 Tuttlingen Germany Phone: +49 7461 708-0 Fax: +49 7461 708-105 E-mail: info@karlstorz.com www.karlstorz.com...

Table of Contents