United States Stove US2000 Owner’s Instruction And Operation Manual

United States Stove US2000 Owner’s Instruction And Operation Manual

Advertisement

Quick Links

Owner's Instruction and Operation Manual
Model Numbers:
US2000
US2000-BL • US2000-BP
US2000-P
US2000-WP • US2000-WL
Report Number: F19-476R3
Tested Per EPA M28R & ASTM E2515 and CSA B415
Certified to UL 1482-2022, CAN/ULC S627:2023
Mobile home / transportable building approved
* All Pictures In This Manual Are For Illustrative Purposes Only. Actual Product May Vary.
Save These Instructions In A Safe Place For Future Reference.
SAFETY NOTICE: If this heater is not properly installed, a house fire may result. For
your safety, follow the installation instructions. Never use make-shift compromises
during the installation of this heater. Contact local building or fire officials about
permits, restrictions and installation requirements in your area. NEVER OPERATE
THIS PRODUCT WHILE UNATTENDED.
CAUTION! Please read this entire manual before you install or use your new room
heater. Failure to follow instructions may result in property damage, bodily injury, or
even death. Improper Installation Will Void Your Warranty!
U.S. Environmental Protection Agency
Certified to comply with 2020 particulate
emissions standards.
THIS MANUAL IS SUBJECT TO CHANGE WITHOUT NOTICE.
© 2024 United States Stove Company, 227 Industrial Park Rd., South Pittsburg, TN 37380
• US2000-L
• US2000-W
R
CALIFORNIA PROPOSITION 65 WARNING:
This product can expose you to chemicals including carbon
monoxide, which is known to the State of California to cause
cancer, birth defects, and/or other reproductive harm. For
more information, go to www.P65warnings.ca.gov
854101-1206N
Ph. 800-750-2723

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the US2000 and is the answer not in the manual?

Questions and answers

Summary of Contents for United States Stove US2000

  • Page 1 State of California to cause emissions standards. cancer, birth defects, and/or other reproductive harm. For more information, go to www.P65warnings.ca.gov THIS MANUAL IS SUBJECT TO CHANGE WITHOUT NOTICE. © 2024 United States Stove Company, 227 Industrial Park Rd., South Pittsburg, TN 37380 Ph. 800-750-2723...
  • Page 2 The instructions pertaining to the installation of your wood stove comply with UL1482-2022 and CAN/ULC S627:2023 standards. This manual describes the installation and operation of the USSC, US2000, US2000-L, US2000-BL, US2000-BP, US2000-P, US2000-W, US2000-WP, US2000-WL wood heater. This heater meets the 2020 U.S.
  • Page 3: Installation Checklist

    Declaration of Completion: As the qualified person responsible for the work described above, I confirm that the appliance as associated work has been installed as per manufacturer’s instructions and following any applicable building and installation codes. Signed: ______________________________________ Print Name: __________________________________Date: ______________ Home Owner: RETAIN THIS INFORMATION FOR FUTURE REFERENCE © 2024 United States Stove Company...
  • Page 4: Tools And Materials

    Mount the flue collar to the top of the unit as shown using the (3) 5/16-18 x 1-1/2 bolts, (3) washers, and (3) weld tabs provided in the parts box. 5/6-8 x 1-1/2 BOLT WASHER GASKET HEATER TOP WELD TAB © 2024 United States Stove Company...
  • Page 5: Installation

    A wood stove IN A FACTORY-BUILT FIREPLACE must never be installed in a hallway or near a staircase, since it may block the way in case of fire or fail to respect required clearances. © 2024 United States Stove Company...
  • Page 6: Floor Protector

    • The chimney connector must not pass through an attic mentioned in this booklet. Installation instructions are or roof space, closet or similar concealed space, a floor, supplied with the air intake kit. Outside combustion air or a ceiling. may be required if: © 2024 United States Stove Company...
  • Page 7 STRUCTURE MOBILE HOME/ building with 8 ga copper wire using a serrated or star TRANSPORTABLE BUILDING. washer to penetrate paint or protective coating to ensure grounding. © 2024 United States Stove Company...
  • Page 8: Chimney Connector (Stove Pipe)

    “plugging” of the chimney. An inadequate draft 4. The draft caused by the tendency for hot air to rise will cause the appliance to leak smoke into the room will be increased with an interior chimney. © 2024 United States Stove Company...
  • Page 9: Factory Built Chimney

    Be sure to the chimney cleaned before the stove is installed and operated. When connecting the stove through a combustible wall to a masonry chimney, special methods are needed. © 2024 United States Stove Company...
  • Page 10 • A chimney connector shall not pass through an attic or roof space, closet or similar concealed space, or a floor, or ceiling. © 2024 United States Stove Company...
  • Page 11 Deadwood lying on the forest floor should be considered GASOLINE, OUT OF THE VICINITY OF THE wet and requires full seasoning time. Standing deadwood APPLIANCE - WHETHER IN USE OR IN STORAGE. can usually be considered to be about 2/3 seasoned. © 2024 United States Stove Company...
  • Page 12: Testing Your Wood

    (draft) chimney, creating potential conditions for a chimney required to properly burn coal or coal products. Do fire. not elevate the fire using grates or irons. Build the fire directly on the firebrick. © 2024 United States Stove Company...
  • Page 13: Fueling Instructions

    17 lbs of fuel for the first high burn load. After the first high burn load and the stove is well warmed up, adjust the unit as needed for a medium or low burn setting. © 2024 United States Stove Company...
  • Page 14: Air Tubes

    Learn to adjust the air settings of your specific unit to produce the smallest amount of visible smoke. Wood that has not been seasoned properly and has a high wood moisture content will produce excess visible smoke and burn poorly. © 2024 United States Stove Company...
  • Page 15: Chimney Maintenance

    CO emitted operating temperatures. The secondary combustion out the chimney, exposure to the gases in closed or can only take place if the firebox is hot enough. © 2024 United States Stove Company...
  • Page 16: Glass Care

    Part numbers and descriptions can be found in the “Repair Parts” section of this manual. Once this information has been gathered you can contact customer service by phone 1-800-750-2723 Ext 5051 or Email parts@usstove.com. Model Information Model Number Serial Number © 2024 United States Stove Company...
  • Page 17 DO NOT INSTALL IN AN ALCOVE non-combustible pad that will provide ember protection. DO NOT INSTALL IN ANY FIREPLACE The 450 mm (18 in) ember protection required on any © 2024 United States Stove Company...
  • Page 18: Repair Parts

    Email to: parts@usstove.com IN ORDER TO MAINTAIN WARRANTY, COMPONENTS MUST BE REPLACED USING ORIGINAL MANUFACTURERS PARTS PURCHASED THROUGH YOUR DEALER OR DIRECTLY FROM THE APPLIANCE MANUFACTURER. USE OF THIRD PARTY COMPONENTS WILL VOID THE WARRANTY. © 2024 United States Stove Company...
  • Page 19 Email to: parts@usstove.com IN ORDER TO MAINTAIN WARRANTY, COMPONENTS MUST BE REPLACED USING ORIGINAL MANUFACTURERS PARTS PURCHASED THROUGH YOUR DEALER OR DIRECTLY FROM THE APPLIANCE MANUFACTURER. USE OF THIRD PARTY COMPONENTS WILL VOID THE WARRANTY. © 2024 United States Stove Company...
  • Page 20: Service Record

    Engineer Name: ____________________________________ Engineer Name: ____________________________________ License No.: ________________________________________ License No.: ________________________________________ Company: __________________________________________ Company: __________________________________________ Telephone No.: _____________________________________ Telephone No.: _____________________________________ Stove Inspected: Chimney Swept: Stove Inspected: Chimney Swept: Items Replaced: ____________________________________ Items Replaced: ____________________________________ © 2024 United States Stove Company...

Table of Contents