Location Requirements

IMPORTANT: Observe all governing codes and ordinances.
Check the location where the air conditioner will be installed.
Make sure you have everything necessary for correct installation.
The location should provide:
■ Grounded electrical outlet within 4 ft (122 cm) of where the
power cord exits the air conditioner.
(For model ESA406J,ESA408J,ESA406J-L,ESA408J-L,
ESA406J-T,ESA408J-T electrical outlet can be grounded within
6 ft (183 cm))
NOTE: Do not use an extension cord.
■ Free movement of air in room to be cooled.
■ A large enough opening for the air conditioner. Installation
parts are supplied for double-hung windows.
■ Adequate wall support for weight of air conditioner. Air
conditioner weighs 48.3 lbs to 76 lbs (21.9 kg to 34.5 kg).
NOTE: Cabinet louvers must not be obstructed. Air must be able
to pass freely through the cabinet louvers.
Window Installation
Window opening measurements:
MODEL
ESA406J ESA406J-L
ESA408J ESA408J-L
Dimension
ESA406J-T ESA408J-T
A(inch) Min
25"(63.5cm)
36"(91.4cm)
A(inch) Max
B(inch) Min
133⁄8"(34cm)
4
A. Cabinet louvers
A. Width
B. Height
ESA410J
ESA412J
ESA410J-T
ESA410J-E
24½"(62.2cm)
38"(96.5cm)
149⁄16"(37cm)
A
The electrical ratings for your air conditioner are listed on the
model and serial number label. The model and serial number
label is located either on the side or back of the air conditioner
cabinet or behind the front grille.
Specific electrical requirements are listed in the chart below.
Follow the requirements for the type of plug on the power supply
cord.
Power Supply
Cord
Recommended Grounding Method
This air conditioner must be grounded. This air conditioner is
equipped with a power supply cord having a 3 prong grounding
plug. The cord must be plugged into a mating, grounded 3 prong
outlet, grounded in accordance with all local codes and
ordinances. If a mating outlet is not available, it is the customer's
responsibility to have a properly grounded 3 prong outlet installed
by a qualified electrical installer.
It is the customer's responsibility:
To contact a qualified electrical installer.
ESA410J-L
ESA412J-L

Electrical Requirements

Wiring Requirements
115-volt (103.5 min. to 126.5 max.)
0 to 12 amps
15-amp time-delay fuse or circuit
breaker
Use on single outlet circuit only.