Haier HUM09HB03 Installation Manual
Haier HUM09HB03 Installation Manual

Haier HUM09HB03 Installation Manual

Room air conditioner
Table of Contents

Advertisement

Available languages

Available languages

Installation Manual of Room Air Conditioner

Preparation
Necessary Tools for Installation
Driver
Nipper
Hacksaw
Hole core drill
Spanner(17,19 and 26mm)
Gas leakage detector or
soap-and-water solution
Power Source
Before inserting power plug into receptacle, check the voltage without fail.
The power source is the same as the corresponding name plate.
Install an exclusive branch circuit of the power.
A receptacle shall be set up in a distance where the power cable can be
reached.Do not extend the cable by cutting it.
Drawing for the installation of indoor and outdoor units
The models adopt HFC free refrigerant R410A
more than 5cm
more than
10cm
Arrangement of piping
directions
Rear left
Rear
Left
right
Right
Below
more than 10cm
The marks from
to
A
in the figure are the
G
parts numbers.
The distance between
the indoor unit and the
floor should be more
than 2m.
more than 60cm
Please be subject to the actual product purchased , the above picture is just for your reference.
Read this manual before installation
Explain sufficiently the operating means to the user according to this manual
NO.00105
Torque wrench
(17mm,22mm,26mm)
Pipe cutter
Flaring tool
Knife
Measuring tape
Reamer
Attention must be paid to
the rising up of drain hose
more than 10cm
more than
10cm
Selection of Installation Place
Indoor Unit
Place, robust not causing vibration, where the body can be supported sufficiently.
Place, not affected by heat or steam generated in the vicinity, where inlet and outlet of the
unit are not disturbed.
Place, possible to drain easily, where piping can be connected with the outdoor unit.
Place, where cold air can be spread in a room entirely.
Place, nearby a power receptacle, with enough space around. (Refer to drawings).
Place where the distance of more than lm from televisions, radios, wireless apparatuses
and fluorescent lamps can be left.
In the case of fixing the remote controller on a wall, place where the indoor unit can
receive signals when the fluorescent lamps in the room are lightened.
Outdoor Unit
Place, which is less affected by rain or direct sunlight and is sufficiently ventilated.
Place, possible to bear the unit, where vibration and noise are not increased.
Place, where discharged wind and noise do not cause a nuisance to the neighbors.
Place, where a distance marked
G
F
Floor fixing dimensions of the
A
outdoor unit (Unit:mm)
C
Fixing of outdoor unit
D
E
more than15cm
is available as illustrated in the above figure.
Optional parts for piping
Non-adhesive tape
A
Adhesive tape
B
Saddle (L.S) with screws
C
Connecting electric cable
D
for indoor and outdoor
E
Drain hose
F
Heating insulating material
Piping hole cover
G
Fix the unit to concrete or block
with bolts (10mm) and nuts firmly
and horizontally.
When fitting the unit to wall
surface, roof or rooftop, fix
a supporter surely with nails
or wires in consideration of
earthquake and strong wind.
If vibration may affect the
house, fix the unit by attaching a
vibration-proof mat.

Advertisement

Table of Contents
loading

Summary of Contents for Haier HUM09HB03

  • Page 1: Installation Manual Of Room Air Conditioner

    Place, robust not causing vibration, where the body can be supported sufficiently. Hacksaw Pipe cutter Place, not affected by heat or steam generated in the vicinity, where inlet and outlet of the Hole core drill Flaring tool unit are not disturbed.
  • Page 2: Indoor Unit

    When connecting the cable before installing the indoor unit Ø60mm Insert the cable from the back side of the unit, then pull it out on the front side. Loosen the screws and insert the cable ends fully into terminal block, then...
  • Page 3: Outdoor Unit

    Be careful that matters, such as wastes of sands, etc. shall not enter the pipe. The standard pipe length is 5m. If it is over 7m, the function of the unit will be affected. If the pipe has to be lengthened, the refrigerant should be charged, 4G1.5mm...
  • Page 4 ‘Lo’ in gaugemanifold and stop the operation of the vacuum pump. Check On Drainage condition of the scale and hold it for 1-2min. If the scale-moves back in spite of tightening, make flaring work again, the return to the beginning of 3 .
  • Page 5 Instale el aparato en un circuito dedicado de alimentación. ● Elija un lugar que permita soportar el peso de la unidad y que no amplifique el ruido Debe existir una toma al alcance del cable de alimentación. No trate de prolongar y las vibraciones.
  • Page 6: Unidad Interior

    Acolchado (4) calor de la unidad interior. 2. Inserte los cables eléctricos de interior / exterior a través de la parte trasera de la unidad interior y tire de ellos desde la parte delantera. A continuación, conéctelos. Placa de montaje (1) Codo de drenaje (1) 3.
  • Page 7: Unidad Exterior

    Cable de alimentación: 3G1.5mm La longitud estándar del tubo es de 5m. Si el tubo tiene más de 7m, se verán afectadas las funciones de la unidad. Si es necesario alargar el tubo, deberá cargarse refrigerante adicional a razón de 20 g/m. No obstante, la carga de refrigerante deberá ser realizada...
  • Page 8: Instalación De La Fuente De Alimentación

    ● No practique el drenaje como se muestra a continuación. 7. Para evitar fugas de gas, gire el tapón del puerto de mantenimiento y el tapón del vástago de las válvulas de 2 y 3 vías un poco por encima del punto en el que la torsión aumenta súbitamente.
  • Page 9: Schema Per L'installazione Dell'unità Interna Ed Esterna

    Più di 15cm Attenersi al prodotto acquistato: le immagini sono solo per riferimento. Leggere questo manuale prima dell’installazione Spiegare all’utente in modo esauriente il funzionamento e l’uso del condizionatore in base alle istruzioni di questo manuale.
  • Page 10: Unità Interna

    ● Allentare le viti ed inserire completamente le estremità del cavo nel blocco terminali, poi strin- Lato esterno gere le viti. Lato interno ● Tirare leggermente il cavo per accertarsi che i cavi siano stati inseriti e fissati in modo appro- Spessore della parete priato. (Sezione del foro su parete) Tubo del foro tubatura ●...
  • Page 11 2 vie e della valvola a stelo della valvola a 3 vie, collegare la non deve essere inferiore a 3mm.
  • Page 12 Inclinato Danno della svasatura Rottura Parziale Troppo esterno 6. Staccare il tubo di carico dalla porta di servizio, aprire la valvola a 2 vie ed a 3 vie. Girare Sullo scarico l'asta della valvola in senso antiorario delicatamente.
  • Page 13 Avant de brancher la fiche dans la prise, vérifiez que la tension est sans faille. La ● Sélectionnez un emplacement qui ne soit pas exposé à la pluie ou à la lumière du jour et source d'alimentation correspond aux informations sur la plaque signalétique.
  • Page 14: Unité Intérieure

    Lorsque la plaque de fixation est installée pour la 1e fois Fixation de l'unité intérieure 1. Exécutez une mise à niveau correcte de la plaque à fixer contre le mur en fonction des piliers ou des linteaux autour, puis attachez la plaque temporairement avec un clou en acier.
  • Page 15: Unité Extérieure

    Unité intérieure Lorsque vous courbez un tuyau, donnez-lui autant de rondeur que possible afin de Unité extérieure ne pas l’écraser ; le rayon de courbure doit être d’au moins 30 à 40 mm, voire plus. Câble électrique : 3G1.5mm Connectez d'abord le côté gaz pour faciliter la suite des travaux.
  • Page 16: Installation Du Bloc D'alimentation

    Vanne à 3 voies 1+2= Vanne à 3 voies Ouvrir 90 Cet appareil contient des gaz à effet de serre fluorés couverts par le protocole de Kyoto. Ne pas venti- ler à l'air. Vanne à 2 voies Type de réfrigérant : R410A Etape 7 Vanne à...

Table of Contents