LawnMaster BPB Series Safety And Operating Manual

LawnMaster BPB Series Safety And Operating Manual

Open frame inverter generators

Advertisement

Quick Links

OPEN FRAME INVERTER
GENERATORS
SAFETY AND OPERATING MANUAL
PLEASE READ THIS MANUAL CAREFULLY BEFORE OPERATING THE UNIT
BPB4000(E) / BPB4500(E) / BPB5000(E)
PROUDLY
A STEELFORT PRODUCT
NZ OWNED

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the BPB Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for LawnMaster BPB Series

  • Page 1 OPEN FRAME INVERTER GENERATORS SAFETY AND OPERATING MANUAL PLEASE READ THIS MANUAL CAREFULLY BEFORE OPERATING THE UNIT BPB4000(E) / BPB4500(E) / BPB5000(E) PROUDLY A STEELFORT PRODUCT NZ OWNED...
  • Page 2: Table Of Contents

    TABLE OF CONTENTS I. OPERATOR SAFETY... 3 II. FEATURES & CONTROLS... 5 CONTROL PANEL... 6 III. OPERATION... 7 OPERATION CHECKLIST... 7 OPERATION CONDITIONS... 8 ENGINE OIL... 8 ENGINE FUEL... 8 ELECTRICAL DEVICES... 9 GROUNDING... 9 IV. STARTING THE GENERATOR... 10 STARTNG FUNCTIONS...
  • Page 3: Operator Safety

    These generators are designed for full time operation. No personal This manual contains important safety information modifications should be made to any part of the unit. and instructions to operate the LawnMaster Inverter Generator. DANGER PLEASE READ THIS MANUAL CAREFULLY BEFORE TOXIC FUMES USING THE UNIT.
  • Page 4 • Empty the fuel tank before storing or • DO NOT leave the generator unattended when transporting the generator. Keep fire it is in operation. Always turn off the generator extinguisher handy at all times. prior to leaving the area. BATTERY ELECTRIC SHOCK •...
  • Page 5: Features & Controls

    II. FEATURES & CONTROLS 1. Muffler 5. Control Panel 9. Support Foot 2. Fuel Cap 6. Frame 10. Valve Cover 3. Fuel Level Indicator 7. Air Filter Housing 11. Inverter 4. Fuel Tank 8. Starter A STEELFORT PRODUCT | STEELFORT.CO.NZ...
  • Page 6: Control Panel

    CONTROL PANEL Oil Alarm Indicator Reset Button 13. V-Type DC Output Overload Indicator Ground Terminal 14. Euro Receptacle Running Indicator Overcurrent Protector 15. Frequency Transfer Switch AC Output Receptacle 10. Engine Switch 16. Load Indicator 12V DC 17. Fuel Level Indicator 11.
  • Page 7: Operation

    III. OPERATION OIL ALARM LAMP (YELLOW) When the oil level drops below the lower limit, the oil protection system will stop the engine automatically and oil alarm lamp will blink located next to the recoil 1. OPERATING CHECKLIST starter. The engine will not run until the oil has been filled to the proper level.
  • Page 8: Operation Conditions

    • Oil is a major factor affecting performance and parts immediately. service life. • We recommend using LawnMaster 4-Stroke WARNING 10W30 Oil (PP01020005). You can find more • Failure to correct problem(s) before operation information about this in the MAINTENANCE may result in property damage and or serious section of this manual.
  • Page 9: Electrical Devices

    6. GROUNDING • Acidic fuels can damage the fuel system while in storage. Be sure to review the instructions in • The generator must be properly connected the “Storage” section. to an appropriate ground. It helps prevent • Petrol/Alcohol Blends: up to 10% alcohol, 90% electrical shock if a ground fault condition unleaded petrol by volume is approved as a exists in the generator or in connected...
  • Page 10: Starting The Generator

    IV. STARTING THE GENERATOR 1. Perform operating checklist. 2. Turn Fuel valve to the “ON” position. 3. Pull the choke valve switch to “ON” position. DANGER Beware of KICKBACK. Rapid retraction of the starter cord will pull hand and arm towards the engine faster than you can let go.
  • Page 11: Connecting To Electrical Devices

    5. When starting, slowly turn choke lever to “OFF” DANGER position as temperature rises. If engine runs unstable (with shakes), shift the lever to “half-open” ELECTRICAL SHOCK position until the engine runs in a stable manner • To reduce the risk of electrical shock, DO NOT before resting the lever in “OFF”...
  • Page 12: Wattage Reference Chart

    WATTAGE REFERENCE CHART TEMPERATURE Ambient temperature: -10 to 60 °C Operation temperature: 0 to 40°C MAINTENANCE Disconnect the battery if you do not intend to use the unit for a long time to prevent battery leakage. Regularly check that the battery post is clean and the connection is secure.
  • Page 13: Parallel Connection

    Turn the fuel valve to “OFF” position Start the engine in proper order and make sure that the running indicator (green) is normal. Connect the plug of electric devices to the AC receptacle of parallel kit. Run the electrical devices. WARNING •...
  • Page 14: Maintenance Schedule

    1. MAINTENANCE SCHEDULE Follow the service intervals indicated in the chart Before servicing the generator, stop the below. Service your generator more frequently when generator, disconnect all electric devices and battery operating in adverse conditions. Contact your local (if equipped) and allow the generator to cool down. Service Dealer if the generator requires maintenance.
  • Page 15: Generator Maintenance

    3. ENGINE MAINTENANCE DO NOT thread cap into tube. 3.1 ENGINE OIL Fully tighten the dipstick. LawnMaster 10W30 Oil (PP01020005) is Dispose of used oil at an approved waste recommended. Other viscosities shown in the chart management facility. may be used when the average temperature in your area is within the indicated range.
  • Page 16: Air Filter

    Add recommended oil to the upper limit (see SPARK PLUG add oil instruction above). Clean any dirt from the spark plug cap and Reinstall and fully tighten the dipstick. spark plug base. Dispose of used oil at an approved waste Remove the spark plug cap.
  • Page 17: Speed

    spark arrester screen with a wire brush. DANGER FIRE OR EXPLOSION Petrol is highly flammable and extremely explosive. Empty the fuel tank and shut off the fuel valve before storing and or transporting the generator. Allow the generator to cool completely before putting it away for storage.
  • Page 18: Troubleshooting

    XI. TROUBLESHOOTING A STEELFORT PRODUCT | STEELFORT.CO.NZ...
  • Page 19: Specifications & Wiring Diagrams

    Notes: Generator with different specifications and configurations may have different parameters. Specifications for LawnMaster generators may change at any time without notice. Please consult your local Service Dealer for detailed information. A STEELFORT PRODUCT | STEELFORT.CO.NZ...
  • Page 20 2. WIRING DIAGRAMS BPB4000 RECOIL START A STEELFORT PRODUCT | STEELFORT.CO.NZ...
  • Page 21 2. WIRING DIAGRAMS BPB4000 ELECTRIC START A STEELFORT PRODUCT | STEELFORT.CO.NZ...
  • Page 22 2. WIRING DIAGRAMS BPB4500/ BPB5000 RECOIL START A STEELFORT PRODUCT | STEELFORT.CO.NZ...
  • Page 23 2. WIRING DIAGRAMS BPB4500E / BPB5000 ELECTRIC START Note: Because of the difference in generators, the wiring diagram is only for reference. A STEELFORT PRODUCT | STEELFORT.CO.NZ...
  • Page 24: Warranty

    In order to be eligible for the LawnMaster at the expense of the owner. All defective limited warranty, you must have,...
  • Page 25 WARRANTY EXCLUSIONS • Normal phenomena such as noise, vibration and or oil, are considered • Any damage which results from by Steelfort as not affecting the neglect of periodic maintenance quality, function or performance of specified by Steelfort. the product. •...
  • Page 26 • Incidental expenses that are piston pins, valve seats, stems and incurred in the warranty claim for bearings. additional expenses such as towing, communications, accommodation • Any damage resulting from exposure and meals, that are incurred due to of the product to soot and smoke, the breakdown of the product at a medicines and chemical agents, remote location are not covered.
  • Page 27 NOTES A STEELFORT PRODUCT | STEELFORT.CO.NZ...
  • Page 28 500 Rangitikei Street Private Bag 11045 Palmerston North, 4442, New Zealand 06 350 1350 | steelfort.co.nz Steelfort Auckland 880 Great South Road, Penrose Auckland, 1061, New Zealand SCAN TO VIEW THE LAWNMASTER RANGE 09 573 1324 | outlet@steelfort.co.nz A STEELFORT PRODUCT steelfortnz...

This manual is also suitable for:

Bpb4000Bpb4500Bpb5000Bpb4000eBpb4500eBpb5000e

Table of Contents