Summary of Contents for LawnMaster BQH3500

  • Page 1 INVERTER GENERATORS SAFETY AND OPERATING MANUAL PLEASE READ THIS MANUAL CAREFULLY BEFORE OPERATING THE UNIT BQH3500(E) / BQH4000(E) PROUDLY A STEELFORT PRODUCT NZ OWNED...
  • Page 2: Table Of Contents

    TABLE OF CONTENTS I. OPERATOR SAFETY... 3 II. FEATURES & CONTROLS... 5 CONTROL PANEL... 5 III. OPERATION... 8 OPERATION CHECKLIST... 8 OPERATION CONDITIONS... 8 ENGINE OIL... 8 ENGINE FUEL... 9 GROUNDING... 10 BATTERY CONNECTION... 10 IV. STARTING THE GENERATOR... 10 STARTING FUNCTIONS...
  • Page 3: Operator Safety

    These generators are designed for full time operation. No personal This manual contains important safety information modifications should be made to any part of the unit. and instructions to operate the LawnMaster Inverter Generator. DANGER PLEASE READ THIS MANUAL CAREFULLY BEFORE TOXIC FUMES USING THE UNIT.
  • Page 4 • Empty the fuel tank before storing or • DO NOT leave the generator unattended when transporting the generator. Keep fire it is in operation. Always turn off the generator extinguisher handy at all times. prior to leaving the area. BATTERY ELECTRIC SHOCK •...
  • Page 5: Features & Controls

    II. FEATURES & CONTROLS Fuel Cap Recoil Starter Muffler Telescoping Handle Oil Drain Plug 10. Muffler Blind Window Control Panel Air Filter Housing 11. Spark Plug Cover Combination Switch Battery Cover Stop - Off - Run - Choke Power Indicator Overload Indicator Running Indicator Oil Alarm Indicator...
  • Page 6 OVERLOAD INDICATOR (RED) Note: If engine stalls or fails to start, turn the When the overload indicator is on, it indicates that combination switch to “RUN” position and then pull the generating set is overloaded and then the AC the recoil starter. If the oil alarming lamp lights up, circuit breaker has tripped.
  • Page 7 COMBINATION SWITCH PARALLEL KIT TERMINAL (STOP & OFF & RUN & CHOKE) It is used for parallel operation with another inverter (parallel kit sold separately). Note: One-button start and remote control start have auto chokes. Stop: Switch to turn the generator off. Note: After the generator is unloaded, please run for 3 minutes with no load to stabilize the temperature, then stop the generator.
  • Page 8: Operation

    III. OPERATION 2. OPERATING CONDITION Check for loose or damaged parts, signs of oil or fuel leaks, and any other condition that may affect proper operation. Repair and or replace with genuine spare 1. OPERATING CHECKLIST parts immediately. OPERATING LOCATION Only use this generator OUTSIDE and in well WARNING ventilated areas.
  • Page 9: Engine Fuel

    • Petrol is highly flammable and extremely • We recommend using LawnMaster 4-Stroke explosive. Keep flammable items away while 10W30 Oil (PP01020005). You can find more handling petrol as this could result in a fire. information about this in the MAINTENANCE •...
  • Page 10: Grounding

    IV. STARTING THE GENERATOR 5. GROUNDING • The generator must be properly connected to an appropriate ground. It helps prevent Pull the starter handle 6-8 times to prefill fuel system electrical shock if a ground fault condition before initial operation or removal from long term exists in the generator or in connected storage.
  • Page 11: Wireless Remote Control

    to start, please allow the generator to cool for at least 1 minute before your next attempt. Failure to do this will damage the starter motor and may void warranty. • If the generator idles for a long period of time due to other improper use/ other factors;...
  • Page 12: Connecting To Electrical Devices

    When electrical device requires a large starting ELECTRICAL SHOCK current, please put the energy-saving switch in the • To reduce the risk of electrical shock, DO NOT “OFF” position; When the starting current required use electrical cords that are worn, frayed, bare by electrical device is small, put the energy-saving or otherwise damaged.
  • Page 13: Wattage Reference Chart

    WATTAGE REFERENCE CHART • When the control distance is shortened or the indicator light is on but the remote control function is not available, Wireless remote replace the battery. Contact your local dealer for more information. ONE BUTTON START-STOP (IF APPLICABLE) •...
  • Page 14: Parallel Connection

    VII. PARALLEL OPERATION VIII. MAINTENANCE Only applicable to some models. It is the operator’s responsibility to complete all Make sure that the generator is in a good running scheduled maintenance and or servicing in a timely state before connecting it to other similar generator manner.
  • Page 15: Maintenance Schedule

    1. MAINTENANCE SCHEDULE Follow the service intervals indicated in the chart Before servicing the generator, stop the below. Service your generator more frequently when generator, disconnect all electric devices and battery operating in adverse conditions. Contact your local (if equipped) and allow the generator to cool down. Service Dealer if the generator requires maintenance.
  • Page 16: Generator Maintenance

    Tampering with the factory reset governor will void your warranty 3. ENGINE MAINTENANCE 3.1 ENGINE OIL LawnMaster 10W30 Oil (PP01020005) is recommended. Other viscosities shown in the chart may be used when the average temperature in your Add recommended oil to the upper limit.
  • Page 17: Air Filter

    CAUTION OIL LEVEL CHECK Reinstall dipstick into tube; rest on oil fill neck, DO NOT thread cap into tube. • Dispose of used oil at an approved waste management facility. 3.3 CHANGING OIL CAUTION Fully tighten the drain bolt before reinstalling Change the oil when in hot engine state.
  • Page 18: Spark Plug

    WARNING SPARK ARRESTER DO NOT run the engine without the air filter, or (IF APPLICABLE) serious danger can result. Allow the generating set to cool completely 5. SPARK PLUG before servicing the spark arrester. Clean any dirt from the spark plug cap and Remove the muffler blind window first.
  • Page 19: Storage & Transport

    IX. STORAGE & TRANSPORTATION STORAGE TRANSPORTATION The generating set should be started at least once When generator is being transported or put into short every 2 weeks and allowed to run for at least 20 term storage, the generator should be in the normal minutes.
  • Page 20: Troubleshooting

    X. TROUBLE SHOOTING A STEELFORT PRODUCT | STEELFORT.CO.NZ...
  • Page 21: Specifications & Wiring Diagrams

    XI. SPECIFICATIONS & WIRING DIAGRAMS 1. SPECIFICATION (PARAMETER TABLE) Note: The generating set with different specification and configurations may have different parameters and may change at any time without notice. A STEELFORT PRODUCT | STEELFORT.CO.NZ...
  • Page 22 2. WIRING DIAGRAMS BQH35000/BQH4000 RECOIL START A STEELFORT PRODUCT | STEELFORT.CO.NZ...
  • Page 23 BQH35000E/BQH4000E ELECTRIC START Note: Because of the difference of generator, the wiring diagram is only for reference. A STEELFORT PRODUCT | STEELFORT.CO.NZ...
  • Page 24: Warranty

    In order to be eligible for the LawnMaster at the expense of the owner. All defective limited warranty, you must have,...
  • Page 25 WARRANTY EXCLUSIONS • Normal phenomena such as noise, vibration and or oil, are considered • Any damage which results from by Steelfort as not affecting the neglect of periodic maintenance quality, function or performance of specified by Steelfort. the product. •...
  • Page 26 • Incidental expenses that are piston pins, valve seats, stems and incurred in the warranty claim for bearings. additional expenses such as towing, communications, accommodation • Any damage resulting from exposure and meals, that are incurred due to of the product to soot and smoke, the breakdown of the product at a medicines and chemical agents, remote location are not covered.
  • Page 27 NOTES A STEELFORT PRODUCT | STEELFORT.CO.NZ...
  • Page 28 500 Rangitikei Street Private Bag 11045 Palmerston North, 4442, New Zealand 06 350 1350 | steelfort.co.nz Steelfort Auckland 880 Great South Road, Penrose Auckland, 1061, New Zealand SCAN TO VIEW THE LAWNMASTER RANGE 09 573 1324 | outlet@steelfort.co.nz A STEELFORT PRODUCT steelfortnz...

This manual is also suitable for:

Bqh3500eBqh4000Bqh4000e

Table of Contents