LawnMaster LGBQH6200 Safety And Operating Manual

LawnMaster LGBQH6200 Safety And Operating Manual

Silent inverter generator

Advertisement

Quick Links

SILENT INVERTER
GENERATOR
SAFETY AND OPERATING MANUAL
PLEASE READ THIS MANUAL CAREFULLY BEFORE OPERATING THE UNIT
LGBQH6200(E)
PROUDLY
A STEELFORT PRODUCT
NZ OWNED

Advertisement

Table of Contents
loading

Summary of Contents for LawnMaster LGBQH6200

  • Page 1 SILENT INVERTER GENERATOR SAFETY AND OPERATING MANUAL PLEASE READ THIS MANUAL CAREFULLY BEFORE OPERATING THE UNIT LGBQH6200(E) PROUDLY A STEELFORT PRODUCT NZ OWNED...
  • Page 2: Table Of Contents

    TABLE OF CONTENTS OPERATOR SAFETY GETTING STARTED Unpacking Usage Of Handle Handle Reset FEATURES & CONTROLS Control Panel OPERATION Operation Checklist Operation Conditions Engine Oil Engine Fuel Operation Place Grounding LGP Cylinder Check Inspection Of Connection With LGP STARTING THE GENERATOR Recoil Start Electric Start CONNECTING TO THE ELECTRICAL DEVICES...
  • Page 3: Operator Safety

    These generators are designed for full time operation. No personal This manual contains important safety information modifications should be made to any part of the unit. and instructions to operate the LawnMaster Inverter Generator. DANGER PLEASE READ THIS MANUAL CAREFULLY BEFORE TOXIC FUMES USING THE UNIT.
  • Page 4: Getting Started

    • Empty the fuel tank before storing or it is in operation. Always turn off the generator transporting the generator. Keep fire prior to leaving the area. extinguisher handy at all times. ELECTRIC SHOCK BATTERY • The generator produces powerful voltage and •...
  • Page 5: Usage Of Handle

    The following steps apply to electric start: HANDLE RESET Connect the battery cable before the first use. Press the handlebutton and hold the lever, push it Unscrew the fixing bolt on the right inward towards the generator to the original position maintenance panel and remove the until the handle makes a “click”...
  • Page 6: Features & Controls

    FEATURES & CONTROLS Fuel Cap Air Inlet Screen Combination Switch (Start (If Equipped), Run, Shut-Off, Fuel Level Indicator Sight Glass Lever And Flameout) Front Lift Handle Left Maintenance Panel Right Maintenance Panel Fuel Port (If Equipped) Wheels Rear Lift Handle Panel Assembly Start Handle Muffler Screen...
  • Page 7 OVERLOAD INDICATOR (RED) Note: If engine stalls or fails to start, turn the When the overload indicator is on, it indicates that combination switch to “RUN” position and then pull the generating set is overloaded and then the AC the recoil starter. If the oil alarming lamp lights up, circuit breaker has tripped.
  • Page 8 Note: After the generator is unloaded, please run for 3 minutes with no load to stabilize the temperature, then stop the generator. SHUT Off: Fuel shut off valve. This position can run out of the remaining fuel to ensure old fuel is not present when generator has not been used for long periods.
  • Page 9: Operation

    This generator may require a high altitude carburetor kit to ensure correct operation at high altitudes. Consult with your local LawnMaster dealer for high altitude kit information if you intend to operate the generator at altitudes above 5, 000 feet (1,500 •...
  • Page 10: Engine Fuel

    WARNING • Oil is a major factor affecting performance and service life. • We recommend using LawnMaster 4-Stroke 10W30 Oil (PP01020005). You can find more information about this in the MAINTENANCE section of this manual. • OIL MUST BE PLACED IN ENGINE BEFORE DANGER STARTING.
  • Page 11: Grounding

    the circuit breaker. It may be difficult to start the cylinder and the other end to the LPG female joint of generator after the electrical device is connected. the panel. Moisten the connector with soapy water The electrical device to be connected must not and start the generator.
  • Page 12: Recoil Start

    ELECTRIC START {IF CONFIGURED) Press and hold the start button for 0.3-5 s and then release it, and the generator will be started, and the start button will be reset automatically. 3. Select according to the actual configuration of the user RECOIL START WARNING To start the generator, hold the handle of the...
  • Page 13: Electric Start

    WARNING Before the operation, please do a routine inspection of the oil. The recommended maintenance interval When the generator output terminal is connected to can be found in the maintenance section. the electrical device and the electrical device is on, it is prohibited to start or shut down the generator.
  • Page 14: Connecting To The Electrical Devices

    LOADING CAPACITY Push by push button You must make sure your generator can supply enough rated (running) and surge (starting) watts for the electrical devices you plan to power at the same time. Follow these simple steps to calculate the running and starting watts that are necessary for your purposes.
  • Page 15: Stopping The Engine

    WARNING Turn the combination switch to "Flameout" position It is necessary to equip with circuit protector or until the fuel in the carburetor oil cup burns out switch to isolate the generating set from the electric and the generator has an automatic flameout. utility when the generating set is mainly 1,1sed for If the combination switch is not turned to "FLAME- backup.
  • Page 16: Maintenance Schedule

    Note 3: Service more frequently under severe, dusty, dirty conditions. Note 4: To be performed by knowledgeable and or experienced owners. However, we recommend using an authorised LawnMaster service agent to conduct all maintenance and servicing need for the purpose of voiding issues with warranty.
  • Page 17: Generator & Engine Maintenance

    Tampering with the factory reset governor will void your warranty 3. ENGINE MAINTENANCE 3.1 ENGINE OIL LawnMaster 10W30 Oil (PP01020005) is recommended. Other viscosities shown in the chart may be used when the average temperature in your area is within the indicated range. OIL MUST BE PLACED IN ENGINE BEFORE STARTING.
  • Page 18: Air Filter

    1. Air Filter Fixing Bolt Place the machine on a level surface which is 300mm higher than the ground. 2. Air Filter Cover Remove the left maintenance panel after 3. Paper Air Filter Element unscrewing the fixing bolts. 4. Air Filter Base Loosen the filter fix bolt and remove the cover of the air filter.
  • Page 19: Spark Killer

    Contact your local LawnMaster dealer for such needs. WARNING Only use the recommended spark plug or equivalent. WARNING...
  • Page 20: Storage & Transport

    STORAGE & TRANSPORTATION STORAGE TRANSPORTATION The generating set should be started at least once When generator is being transported or put into short every 2 weeks and allowed to run for at least 20 term storage, the generator should be in the normal minutes.
  • Page 21: Troubleshooting

    TROUBLE SHOOTING A STEELFORT PRODUCT...
  • Page 22: Specifcations & Wiring Diagrams

    SPECIFICATIONS & WIRING DIAGRAMS 1. SPECIFICATION (PARAMETER TABLE) Note: The generating set with different specification and configurations may have different parameters and may change at any time without notice. A STEELFORT PRODUCT...
  • Page 23 2. WIRING DIAGRAMS BQH6200E ELECTRIC START Note: This circuit diagram is for reference only due to the generator set condition difference A STEELFORT PRODUCT...
  • Page 24: Warranty

    The warranty applies to all new LawnMaster products maintenance by methods other than specified that are identified by their unit serial number. by Steelfort. In order to be eligible for the LawnMaster limited • Any product which has participated in a warranty, you must have, maintenance performed competition racing or rally event.
  • Page 25 Periodical maintenance items such as cleaning, inspection and adjustments. • Any repair and/or adjustment performed by persons other than an authorised LawnMaster dealer, or damage resulting therefrom. All maintenance and repairs conducted by unauthorised LawnMaster service dealers and or persons will void the warranty.
  • Page 26 FIND US www.lawnmaster.co.nz lawnmasternz Steelfort Steelfort Auckland 500 Rangitikei Street, Private Bag 11045 880 Great South Road, Penrose Palmerston North, 4412, New Zealand Auckland, 1061, New Zealand 06 350 1350 09 573 1324...

This manual is also suitable for:

Lgbqh6200e

Table of Contents