Wenglor TPL LBO Series Operating Instructions Manual

Advertisement

INTRODUCTION
This Technical User Guide contains warnings and guidance for correct and safe operation of the product.
These instructions must be followed at all times. wenglorTPL will not be held responsible for problems caused
by using the product contrary to these instructions and the Warranty will be deemed invalid.
UNPACKING
This product is packed at the factory using suitable materials for safe transport. To open the package, do not use
any cutting blade to avoid damaging the product(s). Please use the delivered accessories if needed. (Do not use any
other products or equivalents to replace the delivered accessories).
In the event of damage occurring during shipping, it must be reported to the carrier at time of delivery (including
noting the damage in writing on the delivery documents). It is also your responsibility to notify wenglorTPL in wri-
ting of the damage within 24 hours of receipt of the package. If these instructions are not followed, wenglorTPL
reserves the right not to accept requests for return and exchange of damaged products.
RISK CLASS
The applicable Standard EN-62471 classifies LED Lighting into 4 classes according to their degree of hazard severity.
The table below summarises the risks associated with our standard products.
Color
White WHI, Red 630 nm
IR 850 nm
wenglorTPL can provide guidance notes to minimise photo-biological risks, including the nominal minimum
operating distance. Please contact wenglorTPL through your usual representative for this information.
BEWARE to the infrared light, invisible to the eyes.
To know if the light is on, please refer to the LED indicators.
LBOxxxx
OPERATING INSTRUCTIONS
Class
0
1
Risk
In all cases, wenglorTPL recommends
the use of protection glasses.
none
low

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the TPL LBO Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Wenglor TPL LBO Series

  • Page 1 LBOxxxx OPERATING INSTRUCTIONS INTRODUCTION This Technical User Guide contains warnings and guidance for correct and safe operation of the product. These instructions must be followed at all times. wenglorTPL will not be held responsible for problems caused by using the product contrary to these instructions and the Warranty will be deemed invalid. UNPACKING This product is packed at the factory using suitable materials for safe transport.
  • Page 2 LBOxxxx OPERATING INSTRUCTIONS P2/8 DIMENSIONS Length* Height Width Useful length (mm) (mm) (mm) (mm) LBOx601 47.6 LBOx701 47.6 LBOx801 47.6 LBOx901 1034 47.6 1000 LBOx902 1160 47.6 1125 LBOx903 1285 47.6 1250 * Total length, without connector. For additional sizes and colors, please speak to your responsible sales representative.
  • Page 3: Daisy Chain

    P3/8 WIRING 4 MALE POINTS 5 MALE T CODING POINTS 5 FEMALE POINTS Front view Top view If one of the connectors is not used, please keep the cap to maintain the IP protection. DAISY CHAIN LIGHT N°1 4 male 5 male LIGHT N°2 points...
  • Page 4 LBOxxxx OPERATING INSTRUCTIONS P4/8 CONNECTION M12 Connector 5 male points - DRIVE PNP + dimming NPN + dimming grey DIM 0-10V black blue STROBE brown 24 VDC 24 VDC white STROBE 0-10V 0-10V Light will be in continuous mode by leaving signal on strobe input active. The M12 male connector 5 points is COMPLIANT with the M12 female connector 4 points.
  • Page 5: Led Indicators

    P5/8 VOLTAGE DROP References LB0x601 LB0x701 LB0x801 LB0x901 LB0x902 LB0x903 Max voltage drop in the bar (V) 0.18 0.26 0.35 0.46 0.58 0.72 Power supply cable : 5x0,34² max length for acceptable voltage drop (m)* Linking cable: 5x0,34² ** No restriction if each bar has its own power supply cable. Please contact us for other configuration * Max length for acceptable voltage drop (m).
  • Page 6 LBOxxxx OPERATING INSTRUCTIONS P6/8 STROBE MODE Triggering input > 2 ms Triggering input < 2 ms > 2 ms 1 ms STROBE INPUT 100% LIGHT 15 µs 15 µs 15 µs 15 µs 2 ms DIMMING 0-10V 100% Dimming between 0 & 10 V At 0 Volts, the product reaches 100% of its lighting power.
  • Page 7: Power Supply

    P7/8 POWER SUPPLY LB0x601 LB0x701 LB0x801 LB0x901 LB0x902 LB0x903 Power needed in Strobe (W) Power needed in Continuous Working (W) 55.5 66.6 77.7 88.8 99.9 Minimum functioning Voltage 20V in the light input Normal functioning Voltage 24V in the light input (±10%) Maximum functioning Voltage 30V in the light input PRODUCT LIFETIME...
  • Page 8: Operating Conditions

    Please use a soft and dry cloth. Do not use any abrasive material. Do not use any cleaning solvent or aggressive chemical product. wenglorTPL recommends to use isopropyl alcohol. wenglor Straße 3 88069 Tettnang Germany +49 ( 0 ) 7542 5399 800 support@wenglor.com...

This manual is also suitable for:

Tpl lboi801Tpl lboi701Tpl lboi601Tpl lbor801Tpl lbor701Tpl lbor601 ... Show all

Table of Contents