Advertisement

Quick Links

IntroductIon
This User Guide contains warnings and guidance for correct and safe operation of the product. These instructions
must be followed at all times. wenglorTPL will not be held responsible for problems caused by using the product
contrary to these instructions and the Warranty will be deemed invalid.
unpackIng
This product is packed at the factory using suitable materials for safe transport. To open the package, do not use
any cutting blade to avoid damaging the product(s). Please use the delivered accessories if needed. (Do not use any
other products or equivalents to replace the delivered accessories).
In the event of damage occurring during shipping, it must be reported to the carrier at time of delivery (including
noting the damage in writing on the delivery documents). It is also your responsibility to notify wenglorTPL in wri-
ting of the damage within 24 hours of receipt of the package. If these instructions are not followed, wenglorTPL
reserves the right not to accept requests for return and exchange of damaged products.
rISk claSS
The applicable Standard EN-62471 classifies LED Lighting into 4 classes according to their degree of hazard severity.
The table below summarises the risks associated with our standard products.
Color
White WHI, Red 625 nm,
Cyan 505 nm
IR 860 nm
Beware: infrared light is invisible to the eye.
Please refer to LED Indicators on the product
to determine if it is operating.
opt2424
operatIng InStructIonS
Class
risk
0
none
1
low
2427
IND. CONT. EQ
72HL
For use in class 2 circuits
IND. CONT. EQ
72HL
For use in class 2 circuits
wenglorTPL can provide guidance notes to minimise
photo-biological risks, including the nominal mini-
mum operating distance. Please contact wenglorTPL
through your usual representative for this information.
wenglorTPL recommends the use of protection glasses.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the TPL OPT2424 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Wenglor TPL OPT2424

  • Page 1 opt2424 2427 ➔ operatIng InStructIonS IntroductIon This User Guide contains warnings and guidance for correct and safe operation of the product. These instructions must be followed at all times. wenglorTPL will not be held responsible for problems caused by using the product contrary to these instructions and the Warranty will be deemed invalid.
  • Page 2 opt2424 2427 ➔ operatIng InStructIonS P2/12 dImenSIonS Total length Width Height Total length Width Height rING LOw aNGLe (mm) (mm) (mm) (mm) (mm) (mm) OPT2424 & 2425 OPT2424 & 2425 34.75 + OPT2430 OPT2426 & 2427 OPT2426 & 2427 45.25 + OPT2431 * with connectors: 31 mm.
  • Page 3: Led Indicators

    IND. CONT. EQ 72HL For use in class 2 circuits P3/12 IND. CONT. EQ 72HL For use in class 2 circuits led IndIcatorS Operating mode Strobe electrIcal connectIon M12 – 5 MaLe pINS M12 – 8 MaLe pINS n SeCtOr CONtrOL n pOwer SuppLy n COLOr CONtrOL n StrOBe...
  • Page 4: Remote Control

    opt2424 2427 ➔ operatIng InStructIonS P4/12 CONNECTION: M12 8 MaLe pINS CONNECTOR SeCtOr CONtrOL COLOr CONtrOL OverDrIve eNaBLING LOCk keypaD remote control (connectIon) active overdrive ➞ connect to 24VDC grey Change colors ➞ default color: 1 (if not connected) ➞ color 2 if connected to 24 VDC pink yellow blue...
  • Page 5: Strobe Mode

    IND. CONT. EQ 72HL For use in class 2 circuits P5/12 IND. CONT. EQ 72HL For use in class 2 circuits CONNECTION: M12 5 MaLe pINS CONNECTOR pOwer SuppLy StrOBe DIMMING M12 Connector 5 male pins STROBE STROBE grey + 24 V + 24 V DIM 0-10V black...
  • Page 6 opt2424 2427 ➔ operatIng InStructIonS P6/12 Strobe tImIng lImItS • Standard version: MINIMUM PULSE DURATION µs D max 100 % t max 50 000 Hz frequency • D: duty cycle • t: pulse duration • CW: continuous working FREqUENCy • Overdrive version: MINIMUM PULSE DURATION µs D max...
  • Page 7 IND. CONT. EQ 72HL For use in class 2 circuits P7/12 IND. CONT. EQ 72HL For use in class 2 circuits StrobIng the lIght vIa pnp or npn behavIour Standard Mode Entrée Déclenchement Triggering input pNp/NpN Active Overdrive 5 µs - CW 2 ms max overdrive Overdrive Mode...
  • Page 8 opt2424 2427 ➔ operatIng InStructIonS P8/12 StrobIng the lIght vIa color & Sector Input behavIour To control the LED Color and illuminated Sector, the PNP or NPN trigger signal should be enabled in addition to the Sector or Color control signal(s). Timing diagrams below illustrate rise, fall and delay times. If PNP and sectors are connected to 24V and if you strobe colors, there can be some delays between the trigger signal and the LED current.
  • Page 9: Dimming Control

    IND. CONT. EQ 72HL For use in class 2 circuits P9/12 IND. CONT. EQ 72HL For use in class 2 circuits dImmIng control 100% Dimming between 0 & 10 v. With 0V applied to the Dimming pin, the product is at 100% of its lighting power.
  • Page 10: Keypad Control

    opt2424 2427 ➔ operatIng InStructIonS P10/12 keypad control The OPT2424 ➔ 2427 work in manual control and continuous working (CW) mode by default. To use the remote control, you need to connect the 8 pin cable and apply PNP signals to the relevant pins. They have Color selection Teach and Run mode.
  • Page 11 IND. CONT. EQ 72HL For use in class 2 circuits P11/12 IND. CONT. EQ 72HL For use in class 2 circuits uSer SaFety Do not modify or dismantle all or part of the product. respect the power supply voltages and the connection terminals. ensure power supply is switched off whilst connecting product and turn on only once product is fully connected.
  • Page 12: Product Lifetime

    2006, many of which are still in operation today. LED lifetime and heat management are at the forefront of our design considerations. wenglor Straße 3 88069 Tettnang Germany...

Table of Contents