Intavent Automatic Air Vent
IV22.1 & IV28.1
Installation and Maintenance Instructions
Intatec Ltd
Airfield Industrial Estate
Hixon
Staffordshire
ST18 0PF
In this procedure document we have endeavoured to make the
Tel: 01889 272 180
information as accurate as possible.
Fax: 01889 272 181
We cannot accept any responsibility should it be found that in any
email: sales@intatec.co.uk
respect the information is inaccurate or incomplete or becomes so as a
web: www.intatec.co.uk
result of further developments or otherwise.
© Intatec Ltd 2022

Advertisement

loading
Need help?

Need help?

Do you have a question about the inta-Vent V22.1 and is the answer not in the manual?

Questions and answers

Summary of Contents for intatec inta-Vent V22.1

  • Page 1 Fax: 01889 272 181 We cannot accept any responsibility should it be found that in any email: sales@intatec.co.uk respect the information is inaccurate or incomplete or becomes so as a web: www.intatec.co.uk result of further developments or otherwise. © Intatec Ltd 2022...
  • Page 2: Technical Specification

    Before commencing remove all components from packaging and check each component with the contents list. Ensure all parts are present, before discarding any packaging. If any parts are missing, do not attempt to install your Intavent automatic de-aerator until the missing parts have been obtained. © Intatec Ltd 2022...
  • Page 3 Dimensions IV22.1 Ø57 Ø67 1 14 IV28.1 Ø57 Ø28 Ø67 © Intatec Ltd 2022...
  • Page 4 Components 360˚ Air vent valve Float O-ring seal Upper body Lower body Innovative cartridge Venting lower plug ½" © Intatec Ltd 2022...
  • Page 5 The flow of water entering the de-aerator meets the resistance of the cartridge which captures the air bubbles and once they have reached an adequate size they rise upwards and are expelled by the automatic air vent valve. ü û ü û û û 360˚ © Intatec Ltd 2022...
  • Page 6: Maintenance

    To locate and refit the float turn the upper part of the de-aerator upside-down and then refit the upper part of the de-aerator onto the lower body. A ½" threaded plug is located at the bottom of the de-aerator so that a drain valve can be installed. © Intatec Ltd 2022...
  • Page 7 Maintenance It is important to make sure that the air vent screw is always unscrewed to vent the air automatically. © Intatec Ltd 2022...
  • Page 8 To activate your product warranty please visit www.intatec.co.uk and click on Product Registration Intatec Ltd Airfield Industrial Estate Hixon Staffordshire ST18 0PF Tel: 01889 272 180 Fax: 01889 272 181 email: sales@intatec.co.uk web: www.intatec.co.uk E & O.E 18-10-22 © Intatec Ltd 2022...