Download Print this page

Advertisement

Quick Links

{ S i t e S p e c i f i c a t i o ns } { Pr o d uc t i o n } { K od a k Se r v i c e S up p o r t }
Publication No. SS2616-1
23NOV99
Supersedes SS2616-1
15JUL97
SITE SPECIFICATIONS
for the
KODAK PROFESSIONAL LED II PRINTERS 20P/20R
KODAK PROFESSIONAL LED II PROCESSOR 20P
G130_1000HA
© Eastman Kodak Company, 2000

Advertisement

loading

Summary of Contents for Kodak LED II PRINTER 20R - SITE

  • Page 1 { S i t e S p e c i f i c a t i o ns } { Pr o d uc t i o n } { K od a k Se r v i c e...
  • Page 2: Table Of Contents

    Environment.........
  • Page 3: Site Specifications

    PRINTER through a 28 inch doorway. † Roll-to-roll system only. Operator and Service Access: When fully assembled, the system requires a minimum of 91 cm (36 in.) on each side to allow access for service and operator maintenance. Floor: The system should be installed on a smooth, hard, and level floor surface.
  • Page 4: Electrical Requirements

    Within the US and Canada, the PROCESSOR is supplied with a 2.4-metre (8-foot) POWER CORD which enters the cabinet from below. The power receptacle must be located within 2.4 metres 30 cm (4 feet 1 foot) of the rear of the PROCESSOR.
  • Page 5 Site Specifications Space requirements for a roll-to-processor system 3.5 meters + .3 meters (138 in. + 12 in.) 2.2 meters + .3 meters (86 in. + 12 in.) .91 meters (36 in.) minimum 1.5 meters (60 in.) 2.9 meters (114 in.) Printer .91 meters (36 in.)
  • Page 6 The proper configuration of the SCSI-2 connection will depend on the distance of the host computer from the PRINTER. A single-ended connection can be used if the total distance is less than 6 metres (19.7 feet). The customer must supply a SCSI-2 data CABLE (FAST 20 type) and a SCSI-2 TERMINATOR for single-ended connection. An active FPT type (forced perfect termination) SCSI-2 TERMINATOR is recommended.
  • Page 7: Plumbing Requirements

    Flow rate: 3.8-20 liters per minute (1-5 gallons per minute) Temperature: Hot- 59 C (120 F) minimum temperature. Cold-27 C (80 F) maximum temperature. Practically, the water temperature should be adjusted to 35C (95 F) to minimize the time necessary to bring the PROCESSOR to operating temperature.
  • Page 8 Kodak is a trademark. Printed in U.S.A. • ss2616_1_23nov99.fm EASTMAN KODAK COMPANY Rochester, NY 14650...

This manual is also suitable for:

Rp 50 - siteProfessional led ii 20pProfessional led ii 20rProfessional led ii processor 20p