Download Print this page

Global Industrial 270315 User Manual

Surface mount water bottle refilling station
Hide thumbs Also See for 270315:

Advertisement

Quick Links

User's manual
Customer Service
US: 1-800-645-2986
Surface Mount Water Bottle Refilling Station
System
761251
certified
IAPMO R & T against to NSF/ANSI
42, 53 & 372
WARNING
For indoor commercial use only.
All installation work must be performed by authorized
service personnel.
Two or more people are recommended to lift and
install the unit.
To avoid the risk of property damage and/or personal
injury, mount the unit to a flat finished wall surface
adequate support.
Check local codes for plumbing requirements prior
to installation.
Prior to initial installation, install a shut-off valve (not
included) from the water supply.
• Thoroughly flush all water lines and fittings of all
foreign matter before connecting to the cooler.
Failure to do so will void warranty.
Check for any leaks before initial operation.
• DO NOT attempt to repair or replace any part of your
appliance unless it is specifically recommended in
this manual. All other services should be referred to a
qualified technician.
Manual del usuario
Servicio de atenci n al Cliente
US: 1-800-645-2986
by
TM
ó
Read this manual thoroughly prior to
Read this manual thoroughly prior to
installation, operation or maintenance.
installation, operation or maintenance.
Keep these instructions in a safe location
Keep these instructions in a safe location
Service at 1-800-645-2982.
for future reference. For questions, visit
for future reference. For questions, visit
globalindustrial.com or contact Customer
globalindustrial.com or contact Customer
Service at 1-800-645-2982.
Service at 1-800-645-2982.
• For use with clean, clear potable drinking water only.
• Shut-off water supply during installation to reduce risk
of water damage.
• Ensure proper ventilation by allowing appropriate
clearance of housing louvers to the wall on each side of
the cooler, as specified in rough-in guide.
• DO NOT allow children to play with the appliance.
• Interior of unit may contain sharp edges. Wear gloves
when handling or servicing unit.
• Failure to follow installation instructions will
void warranty.
Note: These fixtures are intended for indoor
commercial use only. Do not expose to freezing
temperatures. The grounding of electrical equipment to
water lines is a common procedure. This grounding
may be in the building or occur away from the
building. This grounding can cause electric
feedback into the water cooler creating an
electrolysis which creates a metallic taste or causes
the water metal content to increase. Connect to water
supply using non-conductive materials.
1
Manuel de l'utilisateur
Service
la client le
à
Canada: 888-645-2986
Model 270315
(761251 + 761215PF)
TM
è
052120

Advertisement

loading
Need help?

Need help?

Do you have a question about the 270315 and is the answer not in the manual?

Questions and answers

Summary of Contents for Global Industrial 270315

  • Page 1 à è US: 1-800-645-2986 Canada: 888-645-2986 US: 1-800-645-2986 Surface Mount Water Bottle Refilling Station Model 270315 (761251 + 761215PF) System 761251 certified IAPMO R & T against to NSF/ANSI Read this manual thoroughly prior to Read this manual thoroughly prior to 42, 53 &...
  • Page 2 Failure to do so will void warranty. service technicians using genuine replacement parts. • Check local codes for electrical requirements. • DO NOT disassemble or modify unit. • Use Global Industrial filter only - Model 761215PF Required Tools: Safety Glasses Voltage/Hertz...
  • Page 3 User's Manual Surface Mount Water Bottle Refilling Station Check local codes for plumbing requirements prior to installation.
  • Page 4 Assembly Instructions Surface Mount Water Bottle Refilling Station Surface Mount Water Bottle Refilling Station Model 761251 CONTENTS Ref. Qty. Description Torx Key Filter Access Door Key Discard after removal Remove top mounting bracket Using a Phillips head screwdriver, remove the Top Wall Mount Bracket fastened to the rear of the Bottle Filler Top Assembly by removing (1)screw.
  • Page 5 Assembly Instructions Wall Mounted Water Bottle Surface Mount Water Bottle Refilling Station Note: To comply with ADA requirements, the base of stencil must be installed 27'' from the floor. See Rough-in Guide for additional See wall mounting tempalte ADA requirements. Note: Before installing brackets to the wall assure power source, water line and drain aligns to opening on unit.
  • Page 6: Operation

    User's Manual Surface Mount Water Bottle Refilling Station Operation Note: Initial water flow may have sputter due to air in the water lines; this will be eliminated once air is purged from all water lines. To operate bottle filler, verify proper dispensing by placing bottle, hand or any opaque object in front of sensor area.
  • Page 7 Wall Mounted Water Bottle User's Manual Surface Mount Water Bottle Refilling Station Programming Settings Accessing the Programming Buttons: To access the programming buttons, open the filter access door on the lower cover using the provided key (H6). The two program buttons are located on the top of the filter access door frame.
  • Page 8: Maintenance

    User's Manual Surface Mount Water Bottle Refilling Station Filter Status Lights 5 LED bars will be displayed When filter level is at 100% 4 LED bars will be displayed When filter level is at 80% When filter level is at 60% 3 LED bars will be displayed When filter level is at 40% 2 LED bars will be displayed...

This manual is also suitable for: