Download Print this page
Global Industrial 761217 User Manual

Global Industrial 761217 User Manual

Wall mounted filtered water cooler

Advertisement

Quick Links

User's manual
Customer Service
US: 1-800-645-2986
Wall Mounted Filtered Water Cooler
WARNING
• Keep compressor in upright position for 24 hours
before water connections and initial power-on. Failure
to do so will void warranty.
• For indoor commercial use only.
• All installation work must be performed by authorized
service personnel.
• Two or more people are recommended to lift and install
the unit.
• To avoid the risk of property damage and/or personal
injury, mount the unit to a flat finished wall surface with
adequate support.
• Check local codes for plumbing requirements prior
to installation.
• Prior to initial installation, install a shut-off valve (not
included) from the water supply.
• Thoroughly flush all water lines and fittings of all foreign
matter before connecting to the cooler. Failure to do so
will void warranty.
• Check for any leaks before initial operation.
• DO NOT attempt to repair or replace any part of your
appliance unless it is specifically recommended in
this manual. All other services should be referred to a
qualified technician.
Manual del usuario
Servicio de atención al Cliente
US: 1-800-645-2986
Model 761217
• For use with clean, clear potable drinking water only.
• Shut-off water supply during installation to reduce risk
of water damage.
• Ensure proper ventilation by allowing appropriate
clearance of housing louvers to the wall on each side
of the cooler, as specified in rough-in guide.
• NEVER wire the compressor directly to an electrical supply.
• DO NOT allow children to play with the appliance.
• Interior of unit may contain sharp edges. Wear gloves
when handling or servicing unit.
• Failure to follow installation instructions will void warranty.
Note: These fixtures are intended for indoor commercial
use only. Do not expose to freezing temperatures.
The grounding of electrical equipment to water lines is
a common procedure. This grounding may be in the
building or occur away from the building. This grounding
can cause electric feedback into the water cooler
creating an electrolysis which creates a metallic taste or
causes the water metal content to increase. Connect to
water supply using non-conductive materials.
1
globalindustrial.ca
Manuel de l'utilisateur
Service à la clientèle
Canada: 888-645-2986
Read this manual thoroughly prior to
installation, operation or maintenance.
Keep these instructions in a safe location
for future reference. For questions, visit
globalindustrial.com or contact Customer
Service at 1-800-645-2982.
052120

Advertisement

loading
Need help?

Need help?

Do you have a question about the 761217 and is the answer not in the manual?

Questions and answers

Summary of Contents for Global Industrial 761217

  • Page 1 Service à la clientèle US: 1-800-645-2986 Canada: 888-645-2986 US: 1-800-645-2986 Wall Mounted Filtered Water Cooler Model 761217 Read this manual thoroughly prior to installation, operation or maintenance. Keep these instructions in a safe location for future reference. For questions, visit globalindustrial.com or contact Customer...
  • Page 2 Cooling System. Failure to do so will void warranty. • DO NOT disassemble or modify unit. Required Tools: • Use Global Industrial filters only – Model 670336 1. Safety Glasses 2. Safety Gloves Voltage/Hertz 115V/60Hz 3.
  • Page 3 User's Manual Wall Mounted Filtered Water Cooler Check local codes for plumbing requirements prior to installation.
  • Page 4 Assembly Instructions Wall Mounted Filtered Water Cooler Model 761217 CONTENTS Ref. Qty. Description Cooling System Lower Cover Mounting Bracket Stainless Steel Pan Filter Access Door Water Filter M4 x 8mm Lg. Torx Pan Head Anti-Theft Screw Torx Key #4 x 1/2 Lg. Phillips...
  • Page 5 Assembly Instructions Wall Mounted Filtered Water Cooler WARNING Use 2 people when completing steps 3A - 3C. Connect Water Lines • Connect water line (#1) from the Stainless Steel Pan to the Water Control Valve (#1) in the Cooling System. Push line until locked into place.
  • Page 6 Assembly Instructions Wall Mounted Filtered Water Cooler Attach mounting bracket to wall Note: To comply with ADA requirements, the base of stencil must be installed 11" to 14 " from the floor. See Rough-in Guide for additional Level ADA requirements. Note: Before installing bracket to the wall, check location of power source, water line and drain.
  • Page 7 Assembly Instructions Wall Mounted Filtered Water Cooler Install water filter • Remove the receiver protective cover from the water filter. • Insert filter into the filter head by turning clockwise until locked into place. Open water control • Turn water control valve #1 to the valve #1 open position.
  • Page 8 User's Manual Wall Mounted Filtered Water Cooler Operation Note: Initial water flow may have sputter due to air in the water lines; this will be eliminated once air is purged from all water lines. To operate drinking fountain, push front or side activation buttons on the stainless steel pan to dispense cooled- filtered water from the bubbler.
  • Page 9 User's Manual Wall Mounted Filtered Water Cooler Programming Settings Accessing the Programming Buttons: To access the programming buttons, open the filter access door on the lower cover using the provided key (H4). The two program buttons are located on the top of the filter access door frame. Resetting Filter Status Note: This step is not required for initial use Programming...
  • Page 10 User's Manual Wall Mounted Filtered Water Cooler Maintenance WARNING • Extra caution should be used to clean mirror finished ALWAYS disconnect power and shut-off main water stainless steel panels, as they can be easily scratched. supplier prior to maintenance. Observe entire unit for •...