WARNING
• Keep compressor in upright position for 24 hours
before water connections and initial power-on. Failure
to do so will void warranty.
• For indoor commercial use only.
• All installation work must be performed by authorized
service personnel.
• Two or more people are recommended to lift and install
the unit.
• To avoid the risk of property damage and/or personal
injury, mount the unit to a flat finished wall surface with
adequate support.
• Check local codes for plumbing requirements prior
to installation.
• Prior to initial installation, install a shut-off valve (not
included) from the water supply.
• Thoroughly flush all water lines and fittings of all foreign
matter before connecting to the cooler. Failure to do so
will void warranty.
• Check for any leaks before initial operation.
• DO NOT attempt to repair or replace any part of your
appliance unless it is specifically recommended in
this manual. All other services should be referred to a
qualified technician.
Manual del usuario
Servicio de atención al Cliente
US: 1-800-645-2986
• For use with clean, clear potable drinking water only.
• Shut-off water supply during installation to reduce risk
of water damage.
• Ensure proper ventilation by allowing appropriate
clearance of housing louvers to the wall on each side
of the cooler, as specified in rough-in guide.
• NEVER wire the compressor directly to an electrical supply.
• DO NOT allow children to play with the appliance.
• Interior of unit may contain sharp edges. Wear gloves
when handling or servicing unit.
• Failure to follow installation instructions will void warranty.
Note: These fixtures are intended for indoor commercial
use only. Do not expose to freezing temperatures.
The grounding of electrical equipment to water lines is
a common procedure. This grounding may be in the
building or occur away from the building. This grounding
can cause electric feedback into the water cooler
creating an electrolysis which creates a metallic taste or
causes the water metal content to increase. Connect to
water supply using non-conductive materials.
1
Manuel de l'utilisateur
Service à la clientèle
Canada: 888-645-2986
Model 761218
Read this manual thoroughly prior to
installation, operation or maintenance.
Keep these instructions in a safe location
for future reference. For questions, visit
globalindustrial.com or contact Customer
Service at 1-800-645-2982.
globalindustrial.ca
052120

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 761218 and is the answer not in the manual?

Questions and answers

Mark
June 3, 2025

water not dispensing to bottle, sensor settings already is on its max.

1 comments:
Mr. Anderson
August 14, 2025

If the Global Industrial 761218 water dispenser is not dispensing water to the bottle despite the sensor settings being at maximum, possible reasons include:

1. Blockage in water line – Check and flush the water supply lines.
2. Infrared sensor range misalignment – Even at maximum sensitivity, the sensor may not detect the bottle if it's not properly aligned.
3. Unit not powered or water supply off – Ensure the unit is plugged in and the main water supply is on.
4. Filter monitor not reset – If the LCD does not show “00000000” at startup, the filter monitor may need to be reset.

Check and address these issues to restore proper operation.

This answer is automatically generated

Summary of Contents for Global Industrial 761218

  • Page 1 Service à la clientèle US: 1-800-645-2986 Canada: 888-645-2986 US: 1-800-645-2986 Wall Mounted Water Bottle Refilling Station Model 761218 Read this manual thoroughly prior to installation, operation or maintenance. Keep these instructions in a safe location for future reference. For questions, visit globalindustrial.com or contact Customer...
  • Page 2: Risk Of Electrical Shock

    Cooling System. Failure to do so will void warranty. • DO NOT disassemble or modify unit. Required Tools: • Use Global Industrial filters only – Model 670336 1. Safety Glasses 2. Safety Gloves Voltage/Hertz 115V/60Hz 3.
  • Page 3 User's Manual Wall Mounted Water Bottle Refilling Station Check local codes for plumbing requirements prior to installation.
  • Page 4 Assembly Instructions Wall Mounted Water Bottle Refilling Station Model 761218 CONTENTS Ref. Qty. Description Cooling System Lower Cover Bottom Mounting Bracket Bottle Filler Top Assembly Back Plate Top Mounting Bracket Gasket Stainless Steel Pan Water Filter Filter Access Door M4 x 8mm Lg. Torx...
  • Page 5 Assembly Instructions Wall Mounted Water Bottle Refilling Station Discard after removal Remove top mounting bracket Remove back plate Using a Phillips head screwdriver, remove the Using a Phillips head screwdriver, remove Back Plate Top Wall Mount Bracket fastened to the rear of from the rear of the Bottle Filler Top Assembly by the Bottle Filler Top Assembly by removing (1) removing (3) screws.
  • Page 6 Assembly Instructions Wall Mounted Water Bottle Refilling Station Connect Water Lines • Connect water line (#1) from the Stainless Steel Pan to the Water Control Valve (#1) in the Cooling System. • Push line until locked into place. • Connect the water line (#2) in the Bottle Filler Top Assembly to the Water Control Valve (#2) in the Cooling System.
  • Page 7 Assembly Instructions Wall Mounted Water Bottle Refilling Station Attach back plate Reattach the Back Plate onto the rear of the Bottle Filler Top Assembly using the (3) screws previously removed, plus (6) (H5) screws. Unit is now ready for mounting. See wall mounting Note: To comply with ADA requirements, the base of stencil must...
  • Page 8: Install Water Filter

    Assembly Instructions Wall Mounted Water Bottle Refilling Station Valve Control • Ensure both water control valves are turned to the closed position. • Attach 2 screws (not included) through the frame of the Cooling System and into the bottom support holes previously drilled into the wall.
  • Page 9 Wall Mounted Water Bottle Refilling Station • Remove the filter access door using the provided key. WARNING Risk Of Electrical Shock • Turn off power prior to performing any maintenance. • Verify supply voltage accuracy. • Ensure all electrical and grounded connections are in Reattach lower cover accordance with the National Electrical Code and any •...
  • Page 10: Operation

    User's Manual Wall Mounted Water Bottle Refilling Station Operation To operate drinking fountain, push front or side activation buttons on the stainless steel pan to dispense cooled- Note: Initial water flow may have sputter due to air in the filtered water from the bubbler. water lines;...
  • Page 11: Programming Buttons

    User's Manual Wall Mounted Water Bottle Refilling Station Programming Settings Accessing the Programming Buttons: To access the programming buttons, open the filter access door on the lower cover using the provided key (H6). The two program buttons are located on the top of the filter access door frame.
  • Page 12: Maintenance

    User's Manual Wall Mounted Water Bottle Refilling Station Filter Status Lights When filter level is at 100% 5 LED bars will be displayed When filter level is at 80% 4 LED bars will be displayed When filter level is at 60% 3 LED bars will be displayed When filter level is at 40% 2 LED bars will be displayed...

Table of Contents

Save PDF