7
Specifications
Capacitance
Frequency
(V AC)
Temperature
(Type K)
Temperature
(IR)
7.4 IR Thermometer Specifications
IR Spectral Response
IR Emissivity
IR Distance to Spot ratio
Laser pointer
#NAS100175; r. AA/97099/97616; en-US
6.000 nF
60.00 nF
600.0 nF
6.000 µF
60.00 µF
600.0 µF
6.000 mF
40.00 mF
9.999 Hz
99.99 Hz
999.9 Hz
9.999 kHz
99.99 kHz
Sensitivity: 100 V (< 50 Hz); 50 V (50 to 400 Hz); 5 V (401 Hz to 4
kHz)
-20 to 760℃ (-4 to
1400℉)
The supplied thermocouple is rated for 250℃ (482℉) maximum. If a
higher temperature range is needed, acquire a suitably rated ther-
mocouple. If a higher temperature is measured with the supplied
probe, damage to the thermocouple and meter is possible.
Specification does not include probe accuracy
-50 to -20℃ (-58 to
-4℉)
-20 to 270℃ (-4 to
518℉)
6 to 16 µm
0.95 (fixed)
8:1
Class 2 laser < 1 mW power; Wavelength: 630 to 670 nm
0.001 nF
±(5.0% + 30 digits)
0.001 nF
±(5.0% + 20 digits)
0.1 nF
±(3.0% + 5 digits)
0.001 µF
0.01 µF
0.1 µF
±(4.0% + 10 digits)
0.001 mF
±(10.0% + 10 digits)
0.01 mF
0.001 Hz
±(1.5% + 2 digits)
0.01 Hz
0.1 Hz
0.001 kHz
0.01 kHz
0.1° < 1000°
± (3.0 % + 5℃ [9℉])
1° > 1000°
0.1°
± 5℃ (9℉)
±2% of reading or ±2℃
(3℉) whichever is
greater