Thank you for purchasing Qlight's products. Please read this user manual carefully
prior to installation and operation to ensure safe and correct use.
Safety Precautions for Explosion Proof Products
Please follow the instruction below to ensure safe and correct use of explosion proof products.
1. Explosion proof products should be managed according to explosion proof regulations. Do not disassemble, assemble, alter or repair
the product arbitrarily.
2. The temperature rating of the product is the temperature the product will experience at the applied rated voltage and ambient
temperature indicated.
3. Use cable glands that satisfy the product's explosion proof grade and temperature grade.
4. Unused cable entries must be filled with material that meets the explosion proof grade and temperature rating.
5. Before installing the product, please make sure all cautions indicated on the labels, packaging, and operation manual of the product
are fully understood.
6. Installation, maintenance and repair of the product must be performed by experts in the explosion proof field, or persons who have
received relevant training.
7. For safety, the product should be installed and operated in environments that avoid high temperature and high pressure.
8. Please follow general safety precautions and avoid installing the product in locations that may generate excessive heat.
9. When installing the product in places where chemicals are located, please make sure that the environment does not have two or more
incompatible chemicals mixed. For safety, please read the instruction manual carefully and be mindful of the chemical compositions
where the product is used.
10. This product requires grounding.
11. Please note that special conditions shall be applied if the sign "X" is placed after the certificate number.
1) For safe use, regular overpressure test must be carried out in accordance with EN 60079-1, clause 15.2.3.
2) For safe use, tempered glass must be protected from strong impact
12. When using NPT cable glands (plugs), it is recommended to use them after applying non-hardening grease to maintain protective
performance.
Precaution for Safety
Failure to follow the instructions below may cause a loss of life or serious physical injury.
1. During wiring or maintenance, please completely turn off the power of the product. (Failure to follow this may lead to an electric shock.)
2. Do not install the product in locations that subjects it to excessive dust or water other than the conditions designated by the IP protection
ratings indicated for each product. (Failure to follow these instructions may cause a fire to the product, electric shock, physical injury,
malfunction or damage to the product.)
3. Do not alter or repair this product. If maintenance or repair service is required, please contact your local Qlight contact point.
(Failure to follow these instructions may lead to fire, electric shock, or product damage.)
4. Please apply the correct voltage to the product. (Failure to follow these instructions may lead to fire, electric shock, or product damage.)
5. When the product is applied to a condition that may impact lives or property, please make sure to have a double safety device.
(Failure to follow this may cause damage to property, fire, electric shock and loss of life.)
Precautions for Correct Use
Failure to follow the proper instructions may cause damage to property, the product, or malfunction of the product
that would void the warranty.
1. Please remove any objects that can interrupt ventilation around the product.
2. Please turn off the power of the product immediately if it fails to operate properly.
3. Carefully wire the product according to each product's specification.
4. Please be careful in preventing chemicals such as thinner, benzene, etc. in contact with the surface of the product.
5. Do not apply excessive force/impact to the product.
6. Failure to follow any of the instructions above may cause malfunction or damage to the product, fire, and electric shock.
Please scan the QR code for more
detailed product information.
www.qlight.com
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the QTEX and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Qlight QTEX

  • Page 1 3. Do not alter or repair this product. If maintenance or repair service is required, please contact your local Qlight contact point. (Failure to follow these instructions may lead to fire, electric shock, or product damage.) 4.
  • Page 2: Ordering Specifications

    4.71kg B-Blue B-Blue AC95V-230V 4.62kg AC95V-230V 4.72kg W-White W-White • Protection rating : IP66 ■ QTEX Light source current(based on 1 layer) ■ QTEXB Light source/buzzer current(based on 1 layer) Voltage Voltage DC12V DC24V AC95V-230V DC12V DC24V AC95V-230V Light source current(1 layer)
  • Page 3 Ø144 Dimensions (Units : mm) QTEX/ QTEXB - Direct mount type model Ø144 Ø124 CABLE ENTRY 3/4" NPT Ø124 2WAY CABLE ENTRY 3/4" NPT 2WAY 156.5 4-Ø9 FITTING HOLES 156.5 BUZZER HOLE 4-Ø9 Ø21.5 FITTING HOLES ※For QTEXB model, buzzer is located on the bottom of the product(QTEXB).
  • Page 4: Wiring Instructions

    General label Wiring Instructions • QTEX/ QTEXB model can be wired with either external contact and transistor. • When wiring with transistor, please make sure to use PNP transistor and follow the wiring instructions in the diagram below. QTEX - DC/AC...
  • Page 5 Instructions above. • After wiring, place the cover around the top of product and turn the cover in the CW direction using the QTEX (B) cover disassembly tool. ※Please make sure to close the terminal block cover completely to prevent failure in waterproofing.
  • Page 6: Mounting Hole Specifications

    Installation Environment and Protection Rating This product is designed for use with non-sparking explosion proof structure. • • Please make sure to use the prduct in a environment where satisfies regulated explosion proof grading. For further information, please visit our website (www.qlight.com). •...
  • Page 7 Product installation direction ■ Install the product in accordance with the manual. Otherwise rainwater or moisture may penetrate into the product. ㆍBEACON/SIGNALING LIGHT ※ For products with a protection rating of less than IPX4, please install it vertically. Power cord inlet part shall not be facing the sky. ㆍ...
  • Page 8 Factory | 185-25, Mukbang-ro, Sangdong-myeon, Gimhae-si, Gyeongsangnamdo, Korea Tel. +82-55-328-1111(Toll free. +82-80-328-1111) Qlight Overseas Sales Dept | 704 Nakdong-daero, Sasang-gu, Busan, Korea(Eomgung-Dong) Tel : +82-51-620-4100 Qlight Public Relations & Marketing Team Office | 704 Nakdong-daero, Sasang-gu, Busan, Korea(Eomgung-Dong) Tel. +82-51-245-0017 SHANGHAI Qlight Electronic Co., Ltd. www.qlight.com www.qlightcn.com | qlightcn@qlight.com China Factory/ Shanghai Sales Office | #Room 333 Building B, #11, Lane 450, Zhenda Road, Baoshan District, Shanghai, China Tel.

This manual is also suitable for:

Qtexb

Table of Contents