PSR-SCP- 24DC/URD3/4X1/2X2/3
PSR-SPP- 24DC/URD3/4X1/2X2/3
Safety Relay as a Contact Extension Block
With Off-Delay Contacts
INTERFACE
Data Sheet
102862_04_en
Description
The PSR-...- 24DC/URD3/4X1/2X2/3 safety relay can be
used as a contact extension block in safety circuits
according to DIN EN 60204-1/VDE 0113-1.
The device has an interface for the T-BUS DIN rail
connector. This interface can be used for single-channel
control and monitoring. Alternatively, the device can also be
operated in single-channel mode via a contact on the basic
device.
Depending on the external wiring, up to safety category 3
according to EN 954-1 can be achieved.
The relay has four enabling current paths, one signaling
current path, and one confirmation path. Depending on the
time set, the contacts drop with a 0.3 ... 3 second delay
according to stop category 1 (DIN EN 60204-1/VDE 0113-1).
The extension unit can be used as a contact multiplier for
emergency stop relays and two-hand controls.
Observe the safety instructions on page 4.
Make sure you always use the latest documentation.
It can be downloaded at www.download.phoenixcontact.com.
A conversion table is available on the Internet at
www.download.phoenixcontact.com/general/7000_en_00.pdf.
This data sheet is valid for all products listed on the following page:
© PHOENIX CONTACT - 09/2007
Features
Contact extension block
Safety category 3 according to EN 954-1
Plug-in screw or spring-cage connection terminal
blocks
Single-channel wiring
Safe isolation
Housing width 22.5 mm
Four enable contacts, one alarm contact, and one
confirmation contact

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PSR-SCP-24DC/URD3/4X1/2X2/3 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Phoenix Contact PSR-SCP-24DC/URD3/4X1/2X2/3

  • Page 1 PSR-SCP- 24DC/URD3/4X1/2X2/3 PSR-SPP- 24DC/URD3/4X1/2X2/3 Safety Relay as a Contact Extension Block With Off-Delay Contacts INTERFACE Data Sheet 102862_04_en © PHOENIX CONTACT - 09/2007 Description Features – Contact extension block The PSR-...- 24DC/URD3/4X1/2X2/3 safety relay can be – Safety category 3 according to EN 954-1 used as a contact extension block in safety circuits –...
  • Page 2: Ordering Data

    48 W 48 V DC 288 W (144 W) 40 W 110 V DC 77 W 35 W 220 V DC 88 W 33 W 250 V AC 1500 VA (750 VA) Minimum switching power 0.4 W 102862_04_en PHOENIX CONTACT...
  • Page 3 Stripping length Screw connection 7 mm Spring-cage connection 8 mm Housing material Polyamide PA, not reinforced Safe isolation, reinforced insulation, and 6 kV between the input circuit/N/C contacts and the enable contact current paths. Tests/Approvals BG/TÜV UL/CUL 102862_04_en PHOENIX CONTACT...
  • Page 4: Safety Instructions

    Otherwise the warranty is invalidated. When operating relay modules, the operator must meet the requirements for noise emission for electrical and electronic equipment (EN 61000-6-4) on the contact side and, if required, take appropriate measures. 102862_04_en PHOENIX CONTACT...
  • Page 5 37-38, 47-48, and 57-58 close. Alarm contacts 15-16 and 65-66 open. If the voltage is switched off at input K1-K2, the enable contacts open and the alarm contacts close after the set time has elapsed. For additional connection examples, see page 7. 102862_04_en PHOENIX CONTACT...
  • Page 6: Connection Notes

    In order to comply with UL approval, use copper cables that are designed for operating temperatures > 75°C. For reliable and safe-to-touch contacts, strip the cable ends as follows: 8 mm 7 mm Figure 5 PSR-SCP- 24DC/URD3/4X1/2X2/3 Figure 6 PSR-SPP- 24DC/URD3/4X1/2X2/3 102862_04_en PHOENIX CONTACT...
  • Page 7: Connection Example

    Figure 7 Wiring via connection terminal blocks © PHOENIX CONTACT 09/2007 PHOENIX CONTACT GmbH & Co. KG • 32823 Blomberg • Germany 102862_04_en Phone: +49 - 52 35 - 30 0 • Fax: +49 - 52 35 - 34 12 00...