Omron SYSDRIVE 3G3JV Setup Manual page 49

Compact simplified inverters
Hide thumbs Also See for SYSDRIVE 3G3JV:
Table of Contents

Advertisement

List of Parameters
Param-
Name
eter
No.
(Regis-
ter No.
(Hex))
n36
Multi-func-
tion input 1
p
(0124)
(0124)
(Input ter-
minal S2)
n37
Multi-func-
tion input 2
(0125)
(Input ter-
minal S3)
n38
Multi-func-
tion input 3
(0126)
(Input ter-
minal S4)
n39
Multi-func-
tion input 4
tion input 4
(0127)
(0127)
(Input ter-
minal S5)
Description
Used to select the functions of multi-function
input terminals S2 through S5.
Set
Function
val-
ue
0
Forward/
3-wire sequence (to be
Reverse
set in n37 only)
rotation
By setting n37 to 0, the
command
set value in n36 is ig-
nored and the following
setting are forcibly made
setting are forcibly made.
S1: RUN input (RUN
when ON)
S2: STOP input (STOP
when OFF)
S3: Forward/Reverse
rotation command (OFF:
t ti
Forward; ON: Reverse)
2
Reverse/
Reverse rotation com-
Stop
mand in 2-wire sequence
(Reversed with the termi-
nal turned ON)
3
External
ON: External fault (FPj
detection: j is a terminal
fault (NO)
number)
4
External
OFF: External fault (EFj
detection: j is a terminal
fault (NC)
number)
5
Fault reset
ON: Fault reset (disabled
while RUN command is
input)
6
Multi-step
Signals to select frequen-
speed ref-
cy references 1 through
8.
erence 1
7
Multi-step
speed ref-
erence 2
8
Multi-step
speed ref-
erence 3
10
Inching fre-
ON: Inching frequency
quency
command (taking prece-
command
dence over the multi-step
speed reference)
11
Accelera-
ON: Acceleration time 2
tion/Decel-
and deceleration time 2
eration time
are selected.
changeover
Set-
ting
range
2 to 8,
10 to
0
22
Description
0, 2 to
8, 10
to 22
2 to 8,
10 to
22
d (OFF
2 to 8,
10 to
10 to
22,
34, 35
Chapter 3
Default
Changes
Memo
setting
during
opera-
tion
2
No
5
No
3
No
6
No
3-9

Hide quick links:

Advertisement

Table of Contents
loading