Instructions for use MASTERmatic LUX M29 L - 1.009.3580, MASTERmatic LUX M07 L - 1.009.3610, MASTERmatic LUX M20 L - 1.009.3620 Table of contents Table of contents 1 User instructions....................... 2 Safety ..........................2.1 Infection hazard......................7 2.2 Improper use ....................... 7 2.3 Technical condition......................
Instructions for use MASTERmatic LUX M29 L - 1.009.3580, MASTERmatic LUX M07 L - 1.009.3610, MASTERmatic LUX M20 L - 1.009.3620 1 User instructions 1 User instructions Dear user, Congratulations on purchasing this KaVo quality product. By following the notes below you will be able to work smoothly, economically and safely.
Page 5
Instructions for use MASTERmatic LUX M29 L - 1.009.3580, MASTERmatic LUX M07 L - 1.009.3610, MASTERmatic LUX M20 L - 1.009.3620 1 User instructions Serial number UDI symbol Manufacturer Note: Please note accompanying documents Follow the electronic instructions for use...
Page 6
Instructions for use MASTERmatic LUX M29 L - 1.009.3580, MASTERmatic LUX M07 L - 1.009.3610, MASTERmatic LUX M20 L - 1.009.3620 1 User instructions CAUTION In cases which – if not prevented – can lead to minor or moderate injury.
Instructions for use MASTERmatic LUX M29 L - 1.009.3580, MASTERmatic LUX M07 L - 1.009.3610, MASTERmatic LUX M20 L - 1.009.3620 2 Safety | 2.1 Infection hazard 2 Safety NOTE All serious events occurring in relation to the product must be reported to the manufacturer and the competent authority of the member state, in which the user and/or patient resides.
Instructions for use MASTERmatic LUX M29 L - 1.009.3580, MASTERmatic LUX M07 L - 1.009.3610, MASTERmatic LUX M20 L - 1.009.3620 2 Safety | 2.4 Accessories and combination with other equipment 4 Check to make sure that the device is working properly and is in satisfactory condition before each use.
Instructions for use MASTERmatic LUX M29 L - 1.009.3580, MASTERmatic LUX M07 L - 1.009.3610, MASTERmatic LUX M20 L - 1.009.3620 2 Safety | 2.6 Service and repair 2.6 Service and repair Repairs, servicing and safety checks may only be performed by trained service personnel.
Instructions for use MASTERmatic LUX M29 L - 1.009.3580, MASTERmatic LUX M07 L - 1.009.3610, MASTERmatic LUX M20 L - 1.009.3620 3 Description of the product | 3 Description of the product MASTERmatic LUX M07 L (Mat. no. 1.009.3610) MASTERmatic LUX M20 L (Mat. no. 1.009.3620) MASTERmatic LUX M29 L (Mat.
Instructions for use MASTERmatic LUX M29 L - 1.009.3580, MASTERmatic LUX M07 L - 1.009.3610, MASTERmatic LUX M20 L - 1.009.3620 3 Description of the product | 3.1 Intended use 3.1 Intended use Indications for use: This medical device is: ▪...
Instructions for use MASTERmatic LUX M29 L - 1.009.3580, MASTERmatic LUX M07 L - 1.009.3610, MASTERmatic LUX M20 L - 1.009.3620 3 Description of the product | 3.3 Transportation and storage conditions 3.3 Transportation and storage conditions CAUTION Startup after refrigerated storage.
Instructions for use MASTERmatic LUX M29 L - 1.009.3580, MASTERmatic LUX M07 L - 1.009.3610, MASTERmatic LUX M20 L - 1.009.3620 4 Startup and shut down | 4.1 Checking the amount of water 4 Startup and shut down WARNING Hazard from contaminated products.
Page 14
Instructions for use MASTERmatic LUX M29 L - 1.009.3580, MASTERmatic LUX M07 L - 1.009.3610, MASTERmatic LUX M20 L - 1.009.3620 4 Startup and shut down | 4.1 Checking the amount of water 14 / 28...
Instructions for use MASTERmatic LUX M29 L - 1.009.3580, MASTERmatic LUX M07 L - 1.009.3610, MASTERmatic LUX M20 L - 1.009.3620 5 Operation | 5 Operation WARNING Rotating dental tool. Cuts, infection and burn injury. 4 Never push the press-button while the dental tool is rotating.
Instructions for use MASTERmatic LUX M29 L - 1.009.3580, MASTERmatic LUX M07 L - 1.009.3610, MASTERmatic LUX M20 L - 1.009.3620 5 Operation | 5.1 Attaching the medical device 5.1 Attaching the medical device WARNING Detaching the medical device during treatment.
Instructions for use MASTERmatic LUX M29 L - 1.009.3580, MASTERmatic LUX M07 L - 1.009.3610, MASTERmatic LUX M20 L - 1.009.3620 6 Checking for malfunctions and troubleshooting | 6.1 Checking for malfunctions 6 Checking for malfunctions and troubleshooting 6.1 Checking for malfunctions CAUTION Overheating of the device.
Instructions for use MASTERmatic LUX M29 L - 1.009.3580, MASTERmatic LUX M07 L - 1.009.3610, MASTERmatic LUX M20 L - 1.009.3620 6 Checking for malfunctions and troubleshooting | 6.2 Troubleshooting 6.2.1 Replacing the O-rings on the motor coupling CAUTION Improper care of the O-rings.
Instructions for use MASTERmatic LUX M29 L - 1.009.3580, MASTERmatic LUX M07 L - 1.009.3610, MASTERmatic LUX M20 L - 1.009.3620 7 Reprocessing steps in accordance with ISO 17664-1 / ISO 17664-2 | 7.1 Preparations at the site of use...
Instructions for use MASTERmatic LUX M29 L - 1.009.3580, MASTERmatic LUX M07 L - 1.009.3610, MASTERmatic LUX M20 L - 1.009.3620 7 Reprocessing steps in accordance with ISO 17664-1 / ISO 17664-2 | 7.2 Manual Reprocessing 7.2 Manual Reprocessing WARNING Incomplete disinfection.
Instructions for use MASTERmatic LUX M29 L - 1.009.3580, MASTERmatic LUX M07 L - 1.009.3610, MASTERmatic LUX M20 L - 1.009.3620 7 Reprocessing steps in accordance with ISO 17664-1 / ISO 17664-2 | 7.2 Manual Reprocessing 7.2.2 Manual internal and external cleaning and internal...
Instructions for use MASTERmatic LUX M29 L - 1.009.3580, MASTERmatic LUX M07 L - 1.009.3610, MASTERmatic LUX M20 L - 1.009.3620 7 Reprocessing steps in accordance with ISO 17664-1 / ISO 17664-2 | 7.3 Automated reprocessing 7.3 Automated reprocessing WARNING Sharp dental tool in the medical device.
Instructions for use MASTERmatic LUX M29 L - 1.009.3580, MASTERmatic LUX M07 L - 1.009.3610, MASTERmatic LUX M20 L - 1.009.3620 7 Reprocessing steps in accordance with ISO 17664-1 / ISO 17664-2 | 7.4 Care products and systems - Servicing 4 Immediately after drying, lubricate the KaVo medical device with care agents from the KaVo care system.
Instructions for use MASTERmatic LUX M29 L - 1.009.3580, MASTERmatic LUX M07 L - 1.009.3610, MASTERmatic LUX M20 L - 1.009.3620 7 Reprocessing steps in accordance with ISO 17664-1 / ISO 17664-2 | 7.5 Packaging 7.4.2 Servicing with KaVo QUATTROcare PLUS KaVo recommends servicing the product as part of the reprocessing after each use, i.e.
Instructions for use MASTERmatic LUX M29 L - 1.009.3580, MASTERmatic LUX M07 L - 1.009.3610, MASTERmatic LUX M20 L - 1.009.3620 7 Reprocessing steps in accordance with ISO 17664-1 / ISO 17664-2 | 7.6 Sterilisation 7.6 Sterilisation Sterilisation in a steam steriliser (autoclave) in...
Instructions for use MASTERmatic LUX M29 L - 1.009.3580, MASTERmatic LUX M07 L - 1.009.3610, MASTERmatic LUX M20 L - 1.009.3620 8 Consumables 8 Consumables Available from specialised dental dealers. Material summary Mat.No. INTRA Instrument stand 3.005.5204 Cleanpac 10 units 0.411.9691...
Instructions for use MASTERmatic LUX M29 L - 1.009.3580, MASTERmatic LUX M07 L - 1.009.3610, MASTERmatic LUX M20 L - 1.009.3620 9 Terms and conditions of warranty 9 Terms and conditions of warranty This KaVo medical device is subject to the following warranty conditions:...