Instructions for use EXPERTmatic E31 C – 1.008.4998 Table of contents Table of contents 1 User instructions....................... 2 Safety ..........................2.1 Infection hazard......................7 2.2 Improper use ....................... 7 2.3 Technical condition......................7 2.4 Accessories and combination with other equipment ............8 2.5 Qualification of personnel....................
Page 5
Instructions for use EXPERTmatic E31 C – 1.008.4998 1 User instructions Serial number UDI symbol Manufacturer Attention: Please consult the accompanying documents Follow the electronic instructions for use HIBC Code CE mark for medical devices EAC conformity mark (Eurasian Conformity)
Page 6
Instructions for use EXPERTmatic E31 C – 1.008.4998 1 User instructions CAUTION In cases which – if not prevented – can lead to minor or moderate injury. NOTICE In cases which – if not prevented – can lead to property damage.
Instructions for use EXPERTmatic E31 C – 1.008.4998 2 Safety | 2.1 Infection hazard 2 Safety NOTE All serious events occurring in relation to the product must be reported to the manufacturer and the competent authority of the member state, in which the user and/or patient resides.
Instructions for use EXPERTmatic E31 C – 1.008.4998 2 Safety | 2.4 Accessories and combination with other equipment ▪ Irregular running noise ▪ Excessive vibration ▪ Overheating ▪ Bur is not seated firmly in the handpiece To ensure optimum function and to prevent property damage, please comply...
Page 9
Instructions for use EXPERTmatic E31 C – 1.008.4998 2 Safety | 2.6 Service and repair As a result of the use of NON-KaVo original spare parts during the repair, parts such as covers may become undone and injure the patient, user or third par- ties.
Instructions for use EXPERTmatic E31 C – 1.008.4998 3 Product description | 3.1 Intended use 3 Product description EXPERTmatic Contra-angle handpiece E31 C (Mat. No. 1.008.4998) The electric driven EXPERTmatic handpieces are dental handpieces in accor- dance with 21 CFR § 872.4200 (dental handpieces and accessories) designed for use by a trained professional in the field of general dentistry only.
Instructions for use EXPERTmatic E31 C – 1.008.4998 3 Product description | 3.2 Technical Specifications E31 C (without light) ▪ Comply with the specified intended use. ▪ Protect himself or herself, the patient and third parties from hazards. ▪ Prevent contamination by the product.
Instructions for use EXPERTmatic E31 C – 1.008.4998 4 Startup and shut-down 4 Startup and shut-down WARNING Hazard from contaminated products. Patients, users or third parties can be infected by contaminated medical de- vices. 4 Prior to initial startup and after each use, process the product and acces- sories.
Instructions for use EXPERTmatic E31 C – 1.008.4998 5 Operation | 5.1 Attaching the medical device 5 Operation WARNING Swallowing or aspiration of loose parts or substances by the patient. Danger of suffocation. 4 Place a rubber dam before each treatment.
Instructions for use EXPERTmatic E31 C – 1.008.4998 5 Operation | 5.4 Removing the bur WARNING Use of non-approved burs. Injury to the patient or damage to the medical device. 4 Comply with the instructions for use and the intended use of the bur.
Page 15
Instructions for use EXPERTmatic E31 C – 1.008.4998 5 Operation | 5.4 Removing the bur 4 Unscrew it or take it off the insert after it has stopped rotating. NOTE Follow the manufacturer's instructions for use when reusing the inserts.
Instructions for use EXPERTmatic E31 C – 1.008.4998 6 Checking for malfunctions and troubleshooting | 6.1 Checking for malfunctions 6 Checking for malfunctions and troubleshooting 6.1 Checking for malfunctions CAUTION Overheating of the device. Burn injury or product damage due to over-heating.
Page 17
Instructions for use EXPERTmatic E31 C – 1.008.4998 6 Checking for malfunctions and troubleshooting | 6.2 Troubleshooting 4 Spray a lint-free cloth with KaVo Spray, apply it to the new O-rings and in- sert them in the recesses. 17 / 28...
Instructions for use EXPERTmatic E31 C – 1.008.4998 7 Processing steps in accordance with ISO 17664-1 / ISO 17664-2 | 7.1 Preparations at the site of use 7 Processing steps in accordance with ISO 17664-1 / ISO 17664-2 7.1 Preparations at the site of use WARNING Hazard from contaminated products.
Instructions for use EXPERTmatic E31 C – 1.008.4998 7 Processing steps in accordance with ISO 17664-1 / ISO 17664-2 | 7.3 Automated preprocessing 7.2.3 Manual external disinfection WARNING Incomplete disinfection. Patients, users or third parties may get infected by contaminated medical de- vices.
Instructions for use EXPERTmatic E31 C – 1.008.4998 7 Processing steps in accordance with ISO 17664-1 / ISO 17664-2 | 7.4 Care products and systems - Servicing NOTICE Never process this medical device in an ultrasonic device. Malfunction and material damage.
Instructions for use EXPERTmatic E31 C – 1.008.4998 7 Processing steps in accordance with ISO 17664-1 / ISO 17664-2 | 7.5 Packaging 4 Remove the bur from the medical device. 4 Cover the medical device with the KaVo Cleanpac bag, and place it on the corresponding care adapter.
Instructions for use EXPERTmatic E31 C – 1.008.4998 7 Processing steps in accordance with ISO 17664-1 / ISO 17664-2 | 7.7 Storage ▪ Sterilizer with gravity displacement method: – 10 minutes at 135 °C (275 °F) Drying time: 30 min. – 15 minutes at 132 ...
Instructions for use EXPERTmatic E31 C – 1.008.4998 8 Optional aids and consumables 8 Optional aids and consumables Available from dental suppliers. Material summary Mat. no. Holder 1.004.0596 INTRA Instrument stand 3.005.5204 Cleanpac 10 units 0.411.9691 Cellulose pad 100 units 0.411.9862...
Instructions for use EXPERTmatic E31 C – 1.008.4998 9 Terms and conditions of warranty 9 Terms and conditions of warranty This KaVo medical device is subject to the following warranty conditions: KaVo grants the end customer a warranty of proper function and guarantees...