3-5 Converting Projects
N
o
t
e
N
o
t
e
N
o
t
Although screen data for the NS5-MQ0[]-V2 is displayed in 16 grayscale levels on the CX-
Designer displays and the NS5-MQ0[]-V2 screen, the data will be displayed in color if it is
converted to data for a PT model with color displays on the CX-Designer or transferred to a PT
with a color display screen. The color codes that are used when creating the screen data for the
NS5-MQ0[]-V2 will be displayed for screen data and the image colors will be used for BMP and
JPEG data.
In order to change the main window size (Maximum Window Size) of the NS-Runtime after
converting the model into the NS-Runtime, change the setting from the Maximum Screen Size
Tab Page in the System Setting Dialog Box (PT Menu – System Setting). For further information,
refer to 3-2 System Settings
Always confirm the communications settings after conversion. Then change the settings
according to the operating environment. For the details on communications settings, refer to 3-3
Communications Settings.
Model Conversion from the NS-Runtime or NSA Series to the NS Series
The NS-Runtime has functionality not supported by the NS-series PTs. Therefore, the
settings of some functions will be changed when the model is converted. It may not be
possible to convert some functions depending on the settings. It that occurs, the conversion
process will be canceled.
Functions that will
have settings
changed and
converted
Functions that may
not be converted
depending on the
setting
After the PT models are converted, the screens will be resized as listed below.
Model before
conversion
NS-Runtime or NSA
3-16
e
Function
Screen size
Communications
settings (serial port
A/B)
Document display
object
Document display
settings
Alarm/event
settings
System settings
Data log settings
Macros
Model after
conversion
NS15
NS12
NS10
NS8
NS5-SQ/TQ
NS5-MQ
Conversion
The screen size will be converted to match the specified
NS-series PT. (Refer to the following table for details.)
If Host Link is set, the communications conditions will be
converted. (Refer to the following table for details.)
If Toolbus is set, it will be converted to NT Link (1:N). (Refer
to the following table for details.)
Document display objects will be deleted from the screens.
These settings will be cleared.
Any settings to display a document on a document display
object will be cleared.
The settings for the saving destination for history data will
be cleared.
The settings for the saving interval will be cleared.
Conversion will not be performed if the number of records in
the log exceeds 50,000 for a normal log.
Macros used will not be converted if they supported only by
the NS-Runtime.
Screen Size
Base screens will be resized to 1,024 x 768 dots.
Base screens will be resized to 800 x 600 dots.
Base screens will be resized to 640 x 480 dots.
Base screens will be resized to 640 x 480 dots.
Base screens will be resized to 320 x 240 dots.
Base screens will be resized to 320 x 240 dots.