Specifications Ratings - Omron MK-SX Datasheet

Power relay
Table of Contents

Advertisement

MK-S(X)
Specifications
Ratings
Operating Coil
Item
Rated current (mA)
Rated voltage (V)
50 Hz
24
110
100
26.6
110
24.2
120
22.2
AC
200
13.3
220
12.1
230
11.5
240
11.0
12
126
24
63.2
DC
48
32.0
110
13.6
220
Note: 1. The rated current and coil resistance are measured at a coil temperature of 23°C with tolerances of +15%/−20% for AC rated current and
±15% for DC coil resistance.
2. Performance characteristic data are measured at a coil temperature of 23°C.
3. The maximum allowable voltage is the maximum value of the allowable voltage range for the operating power supply for the relay coil.
There is no continuous allowance.
4. The rated current is approximately 5 mA higher for Models with Built-in Operation Indicators (DC operating coils).
2
Must
Coil
operate
resistance
voltage (V)
(Ω)
60 Hz
96.3
48.4
23.1
760
21.0
932
19.3
1,130
11.6
3,160
10.5
3,550
10.0
4,250
80% max.
9.6
4,480
95
380
1,500
8,060
6.8
32,200
Must
Maximum
release
voltage
voltage (V)
allowable (V)
Percentage of rated voltage
30% min. at
60 Hz
25% min. at
50 Hz
110%
15% min.
Power
consumption
(VA, W)
Approx. 2.3 VA
at 60 Hz
Approx. 2.7 VA
at 50 Hz
Approx. 1.5 W