Use the Enphase IQ Terminator (Q-TERM-R-10) to seal unused cable ends. It is sold in packs of ten.
For full installation instructions for the Enphase IQ Series Microinverters, read and follow all warnings and
instructions in this guide and in the Microinverter Installation and Operation Manual at:
https://enphase.com/en-fi/installers/resources/documentation. Safety warnings are listed to the right of this
guide.
Terminating unused ends of IQ Cable
A ) Remove 13 mm of the cable sheath from the conductors. Use the terminator loop to measure.
Terminator body
B ) Slide the hex nut onto the cable.
C ) Insert the cable into the terminator body so that each of the two wires land on opposite sides of the
internal separator. There is a grommet inside of the terminator body that should remain in place.
D ) Insert a screwdriver into the slot on the top of the terminator to hold it in place, and torque the hex nut
to 7 N m.
NOTE: Hold the terminator body stationary with the screwdriver and
turn only the hex nut to prevent the conductors from twisting out of the
separator.
E ) Attach the terminated cable end to the PV racking with a cable clip
or tie wrap so that the cable and terminator do not touch the roof.
WARNING: The terminator cannot be re-used.
If you unscrew the nut, you must discard the
terminator.
13 mm
Hex nut
Internal view
SAFETY
IMPORTANT SAFETY INSTRUCTIONS.
SAVE THIS INFORMATION.
This guide contains important instructions to
follow during installation.
Safety Symbols
+
DANGER: This indicates a hazardous situation,
which if not avoided, will result in death or
serious injury.
*
WARNING: This indicates a situation where fail-
ure to follow instructions may be a safety hazard
or cause equipment malfunction. Use extreme
caution and follow instructions carefully.
NOTE: This indicates information particularly
important for optimal system operation.
Safety Instructions
DANGER: Risk of electric shock. Do not use
+
Enphase equipment in a manner not specified by
the manufacturer. Doing so may cause death or
injury to persons, or damage to equipment.
DANGER: Risk of electric shock. Be aware that
+
installation of this equipment includes risk of
electric shock.
DANGER: Risk of electric shock. Always de-ener-
+
gize the AC branch circuit before servicing. Never
disconnect the DC connectors under load.
DANGER: Risk of electric shock. Risk of fire. Only
+
use electrical system components approved for
wet locations.
DANGER: Risk of electric shock. Risk of fire. Only
+
qualified personnel should troubleshoot, install, or
replace Enphase microinverters or the IQ Cable
and accessories.
DANGER: Risk of electric shock. Do not install
+
the IQ Terminator while the power is connected.
DANGER: Risk of electric shock. Risk of fire.
+
When stripping the sheath from the IQ Cable,
make sure the conductors are not damaged.
If the exposed wires are damaged, the system
may not function properly.
WARNING: Before installing or using the Enphase
*
microinverter, read all instructions and cautionary
markings in the technical description, on the
Enphase microinverter system, and on the photo-
voltaic (PV) equipment.
WARNING: Use a terminator only once. If you
*
open the terminator following installation,
the latching mechanism is destroyed. If the
latching mechanism is defective, do not use the
terminator. Do not circumvent or manipulate the
latching mechanism.
WARNING: When installing the IQ Cable, secure
*
any loose cable to minimize tripping hazard
NOTE: To ensure optimal reliability and to meet
warranty requirements, install the cable termina-
tor according to the instructions in this guide.
Safety Instructions Continued
NOTE: Maintenance and cleaning must be per-
formed by qualified personnel.
NOTE: Perform all electrical installations in accor-
dance with all applicable local electrical codes.
NOTE: When looping the IQ Cable, do not form
loops smaller than 12 cm in diameter.
NOTE: When installing the IQ Cable and accesso-
ries, adhere to the following:
• Do not expose the terminator or cable connec-
tions to directed, pressurized liquid (water jets,
etc.).
• Do not expose the terminator or cable connec-
tions to continuous immersion.
• Do not expose the terminator or cable connec-
tions to continuous tension (e.g., tension due to
pulling or bending the cable near the connection).
• Use only the connectors and cables provided.
• Do not allow contamination or debris in the
connectors.
• Use the terminator and cable connections only
when all parts are present and intact.
• Do not install or use in potentially explosive envi-
ronments.
• Do not allow the terminator to come into contact
with an open flame.
• Fit the terminator using only the prescribed tools
and in the prescribed manner.
• Use the terminator to seal the conductor end of
the IQ Cable; no other method is allowed.
Note for third-party products:
Any third-party manufacturer or importer product(s) used to
install or commission Enphase product(s) shall comply with
the applicable EU Directive(s) and requirements in the EEA
(European Economic Area). It is the responsibility of the installer
to confirm that all such products are labelled correctly and have
the required compliant supporting documentation.
Compliance with EU Directives
This product complies with the following EU Directives and can
be used in the European Union without any restrictions.
• Low Voltage Directive (LVD) 2014/35/EU
• Restriction of Hazardous Substances (RoHS) 2011/65/EU
The full text of the EU declaration of conformity (DoC) is available
at
https://enphase.com/en-fi/installers/resources/documenta-
tion.
Manufacturer:
Enphase Energy Inc.,
47281 Bayside Pkwy, Fremont, CA, 94538,
The United States of America, PH: +1 (707) 763-4784.
Importer:
Enphase Energy NL B.V.,
Het Zuiderkruis 65, 5215MV, 's-Hertogenbosch,
The Netherlands, PH: +31 73 3035859.

Advertisement

loading
Need help?

Need help?

Do you have a question about the Q-TERM-R-10 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for enphase Q-TERM-R-10

  • Page 1 IQ Terminator (single-phase) quick install guide - FI SAFETY Safety Instructions Continued Use the Enphase IQ Terminator (Q-TERM-R-10) to seal unused cable ends. It is sold in packs of ten. ✓ NOTE: Maintenance and cleaning must be per- IMPORTANT SAFETY INSTRUCTIONS.
  • Page 2 140-00113-03 December 2023 Initial release. © 2023 Enphase Energy. All rights reserved. Enphase, the e and CC logos, IQ, and certain other marks listed at Enphase Support: https://enphase.com/contact/support https://enphase.com/trademark-usage-guidelines are trademarks of Enphase Energy, Inc. in the US and other coun-...