Correct Use - Omron E3G Datasheet

Photoelectric switch with built-in amplifier (long distance) in plastic housing
Table of Contents

Advertisement

Zone teaching
Pro-
ce-
dure
Set the mode selector to
1
Set the NORMAL/ZONE mode selector to
2
Press the
button with the background.
TEACH
The teaching indicator (red) will turn ON and the teaching
3
indicator (green) will then turn ON.
Set the mode selector to
4
mode.)
Note: Perform zone teaching with the background.
Precautions

Correct Use

E3G-R/MR
Design
Power Supply
A full-wave rectification power supply can be used with the
E3G-MR19(T)-G.
Wiring Considerations
The tensile strength of the cable during operation should not
exceed the values shown below.
Model
Tensile strength
E3G-R13-G
50 N max.
E3G-MR19(T)-G
E3G-R17-G
10 N max.
● For adjustment
Display
• The following graphs indicate the status of each operation
level.
• Set the E3G so that it will work within the stable operation
range.
Stability indicator (green)
Stable
operation
ON
range
(see note)
Operation
level x 1.2
Unstable
OFF
operation
Operation
range
level
(see note)
Operation
level x 0.8
Stable
operation
ON
range
(see note)
Note: If the operation level is set to the stable operation range, the E3G will operate with
the highest reliability and without being influenced by temperature change, voltage
fluctuation, dust, or setting change.
A-128
Operation
.
TEACH
.
ZONE
. (Set to L-ON or D-ON
RUN
Operation indicator (Orange)
L · ON
D · ON
OFF
ON
OFF
ON
Maximum distance setting (in normal mode)
If you want to set the maximum distance of the sensor, set a
maximum distance as depicted in the following procedure.
Pro-
ce-
dure
Set the mode selector to
1
Set the NORMAL/ZONE mode selector to
2
Press the
button 3 s or more.
TEACH
The teaching indicator (red) will turn ON.
3
In 3 s, the teaching indicator (green) will turn ON.
When the teaching indicator (green) turns ON, the setting
is complete. Set the mode selector to
4
D-ON.)
E3G-L/ML
Design
Power Supply
A full-wave rectification power supply can be used with the
E3G-ML79(T)-G.
Wiring Considerations
The tensile strength of the cable during operation should not
exceed the values shown below.
Model
Tensile strength
E3G-L73
50 N max.
E3G-ML79(T)-G
E3G-L77
10 N max.
Miscellaneous
EEPROM Write Error
If a write error occurs (operation indicator flickers) due to pow-
er-off, static electricity or other noise in the teaching mode,
perform teaching again.
E3G-M#(T)-G
Wiring Considerations
• The cable with an external diameter of 6 to 8 mm is recom-
mended.
• Securely tighten the cover to maintain water resistance and
dust resistance. The thread size of the conduit socket is PG
13.5
• Do not tighten with the cable caught by the terminal protec-
tion cover. Otherwise, the water-resistant structure and like
cannot be maintained.
Standard Photoelectric Sensors
Operation
.
TEACH
.
NORMAL
. (Set to L-ON/
RUN

Hide quick links: