Omron CX-PROGRAMMER V8.1 Operation Manual page 225

Function blocks/ structured text
Table of Contents

Advertisement

Function Descriptions
Related Auxiliary Area Flag
Communications Instruction
Enable Flag
Related CPU Bus Unit Area bits
n = CIO 150 + 25 x unit number
Port 1: n+9
Port 2: n+19
n = CIO 150 + 25 x unit number
Port 1: n+9
Port 2: n+19
n = CIO 150 + 25 x unit number
Port 1: n+10
Port 2: n+20
For further information and precautions on related Auxiliary Area flags, refer to the section on RXDU Serial
Communications Instruction in the CS/CJ-series Instruction Reference Manual.
Angle Conversion Functions
DEG_TO_RAD: Convert Degrees to Radians
• Function
Converts an angle in degrees to radians.
• Application
Return_value := DEG_TO_RAD (argument)
• Arguments and Return Values
Variable name
Argument
Return_value
RAD_TO_DEG: Convert Radians to Degrees
• Function
Converts an angle in radians to degrees.
• Application
Return_value := RAD_TO_DEG (argument)
• Arguments and Return Values
Variable name
Argument
Return_value
200
Address
A202.00 to
A202.07
Bit
06
07
---
Data type
REAL, LREAL
REAL, LREAL
Data type
REAL, LREAL
REAL, LREAL
ON when network communications can be executed. The bit
numbers correspond directly to the internal logic port numbers
Bits 00 to 07: Internal logic ports 0 to 7
ON when reception has been completed in no-protocol mode.
ON when a data overflow occurred during reception in no-pro-
tocol mode.
Contains the number of characters received in no-protocol
mode.
Description
Specifies an angle in degrees.
Returns an angle in radians.
Description
Specifies an angle in radians.
Returns an angle in degrees.
Appendix C

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sysmac ws02-cxpc1-v8Sysmac cx-programmer 8.1