Omron CP1H-CPU - 05-2006 Operation Manual page 344

Cp1h cpu unit
Table of Contents

Advertisement

Pulse Outputs
Preparation
PLC Setup
Enable using built-in input IN0 as an interrupt input.
Note The interrupt input setting is read when the power supply is turned ON.
DM Area Settings
Speed Control Settings to Feed Wrapping Material to Initial Position
Acceleration rate: 1,000 Hz/4 ms
Target frequency: 10,000 Hz
Positioning Control Settings for Wrapping Material
Acceleration rate: 500 Hz/4 ms
Deceleration rate: 500 Hz/4 ms
Target frequency: 10,000 Hz
Number of output pulses: 5,000 pulses
Starting frequency: 0 Hz
Setting details
Setting details
Setting details
Section 5-3
Address
Data
D0
#03E8
D1
#2710
D2
#0000
Address
Data
D10
#01F4
D11
#01F4
D12
#2710
D13
#0000
D14
#1388
D15
#0000
D16
#0000
D17
#0000