Omron trajexia CJ1W-MCH72 Operation Manual page 121

Sysmac cj-series programmable controller
Hide thumbs Also See for trajexia CJ1W-MCH72:
Table of Contents

Advertisement

All BASIC commands
4-2-44 CAMBOX
110
/i
Type
Axis command
Syntax
CAMBOX(start_point, end_point, table_multiplier, link_distance,
link_axis [ , link_option [ , link_position ]])
Description
The CAMBOX command is used to generate movement of an axis fol-
lowing a position profile in the TABLE variable array. The motion is
linked to the measured motion of another axis to form a continuously
variable software gearbox. The TABLE values are absolute position rel-
ative to the starting point and are specified in encoder edges.
The TABLE array is specified with the TABLE command. The move-
ment can be defined with any number of points from 3 to the maximum
table size available (64000). Being able to specify the start point allows
the TABLE array to be used to hold more than one profile and/or other
information. The CJ1W-MCH72 moves continuously between the val-
ues in the TABLE to allow a number of points to define a smooth profile.
Two or more CAMBOX commands can be executed simultaneously
using the same or overlapping values in the TABLE array.
The CAMBOX command requires the start element of the TABLE to
have value zero. Note also that CAMBOX command allows traversing
the TABLE backwards as well as forwards depending on the Master
axis direction.
The link_option argument can be used to specify different options to
start the command and to specify a continuous CAM. For example, if
the link_option is set to 4 then the CAMBOX operates like a "physical"
CAM.
CAMBOX works on the default basis axis (set with BASE) unless AXIS
is used to specify a temporary base axis.
Note: While CAMBOX is being executed, the ENDMOVE parameter will
be set to the end of the previous move. The REMAIN axis parameter
will hold the remainder of the distance on the link axis.
Arguments
start_point
The address of the first element in the TABLE array to be used.
end_point
The address of the end element in the TABLE array.
table_multiplier
The Table multiplier value used to scale the values stored in the
TABLE. As the TABLE values are specified in encoder edges, use
this argument to set the values for instance to the unit conversion
factor (set by UNITS parameter).
link_distance
The distance in user units the link axis must move to complete the
specified output movement. The link distance must be specified as a
positive distance.
link_axis
The axis to link to.
link_option
See the table below.
/i
link_option
value
1
Link starts when registration event occurs on link axis.
2
Link starts at an absolute position on link axis (see link_position).
Description