Sunpro electric boosted solar water heater (32 pages)
Summary of Contents for Dux titan 50C336
Page 1
Owner’s Manual Commercial Electric Storage Water Heater Model: 50C336 Installation Details Owner’s Information Warranty For advice, repairs and service, call: 1300 365 115 (Australia) 0800 729 389 (New Zealand) Carefully remove all packaging and transit protection from the heater before installation.
Page 2
Owner’s Manual – 50L Commercial Electric Storage Water Heater Important Safety Information WARNING – THIS APPLIANCE DO NOT MODIFY THIS WATER HEATER. MAY DELIVER WATER AT HIGH DO NOT OPERATE THE WATER HEATER TEMPERATURE. REFER TO THE WITH ANY PANELS OR COVERS PLUMBING CODE OF AUSTRALIA REMOVED.
Page 3
PTR Valve or and heating elements. a faulty thermostat. COLD WATER CONNECTION: Turn off the water heater and contact Dux The water heater is intended to be After Sales and Service. permanently connected to the water supply OVER-TEMPERATURE ENERGY main, and not connected by a hose-set.
Page 4
The pipework must Other methods of compliance are available. not be used to support the water heater. Dux recommends that installations conform Where the water heater is subjected to wet with AS/NZS 3500.4. conditions, a plinth should be installed under NOTE FOR VICTORIA: the water heater.
Owner’s Manual – 50L Commercial Electric Storage Water Heater Plumbing Connections Relief Valve: AS/NZS 3500.4 for guidance on these types The Pressure & Temperature Relief (PTR) of installations. Valve along with insulation is supplied with Hot Water Connection: the water heater. The hot water pipe is to be connected to the The PTR Valve rating is 1,000 kPa and RP ¾"...
Page 8
Incoloy heating element. valve and the water heater. Please consult Dux After Sales and Service The expansion control valve should be set for advice if required. at 850 kPa. Refer to AS/NZS 3500.4 for...
Owner’s Manual – 50L Commercial Electric Storage Water Heater Filling and Draining Filling the Water Heater: Draining the Water Heater: The water heater must be filled with water Turn off the electricity supply to the before turning on the electrical supply. water heater.
Owner’s Manual – 50L Commercial Electric Storage Water Heater Electrical Supply General: When the supply wiring has been The 50C336 model is designed for three connected, ensure the wires are kept phase 400-415V a.c. supply only. The away from the inner tank, thermostats electrical connection must comply with and heating elements.
Page 11
Owner’s Manual – 50L Commercial Electric Storage Water Heater Electrical Supply DANGER Wiring Diagram: BLACK BLACK ELEMENT ELEMENT BLACK ELEMENT WARNING 029499 Rev A...
This service should only be carried out by safely and efficiently. a licensed tradesperson. We recommend your local Dux Service Agent. Your water heater warranty is not conditional on completing the regular In locations where the water has Total servicing recommended in this manual.
Replace faulty tap washers and arrange problem has not been identified, please for your plumber to rectify any leaking pipe work. contact Dux After Sales and Service. • Is the Pressure & Temperature Relief Valve discharging too much water? See below...
Tank Failure Warranty: 100 km from a Dux office or Dux agent, the Owner Dux warrants against failure of the storage tank, will be responsible under the warranty for paying...
Page 15
To the extent permitted by law the liability of number of the water heater. This can be Dux shall be limited to the cost of the repair or found on the compliance plate on the replacement of the water heater.
Page 16
Please take a moment to fill out your details for warranty Commercial Electric Storage registration at: Water Heater www.dux.com.au/warranty For advice, repairs and service, call: or use your smartphone to scan this code: 1300 365 115 (Australia) 0800 729 389 (New Zealand)
Need help?
Do you have a question about the titan 50C336 and is the answer not in the manual?
Questions and answers