Table of Contents

Advertisement

Quick Links

Handbuch
Datafox EVO 2.8 Pure
Flexible data collection with method

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the EVO 2.8 Pure and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Datafox EVO 2.8 Pure

  • Page 1 Handbuch Datafox EVO 2.8 Pure Flexible data collection with method...
  • Page 2 Datafox GmbH. The assertion of all rights in this respect is reserved to Datafox GmbH, especially in case of the grant of a patent. The handover of this documentation does not establish a claim to the license or the use of the soft- and hardware.
  • Page 3 Datafox MasterIV, SW version xxx.pdf list as shown. The file is located on the Datafox DVD and for download on the homepage. Please also note the in- structions in each chapter in the manual. The updates are available on our website under www.da- tafox.de download.
  • Page 4: Table Of Contents

    Display and Bios of the EVO-Line 2.8 Pure ..............18 5.2.1.1. Structure of normal display ..................18 5.2.1.2. Structure of display EVO 2.8 Pure in the Bios menu ..........19 5.2.1.3. Bios Menu Setting WLAN ..................23 5.2.1.4. Setting of the Proximity- & ambient Light-Sensor ............26 5.2.2.
  • Page 5 Preview of reader behavior ..................85 5.8.2.8. Transfer to the device ....................85 5.8.3. Access control II with PHG-Modules ................86 5.8.3.1. Connecting of PHG-reader ..................87 5.8.3.2. Configuration ......................94 Handbuch Datafox EVO 2.8 Pure page V Datum: 18.04.2024 Version: 04.03.21...
  • Page 6 5.8.12.10. Supported transponder technologies ............... 142 1.1.1.1 Service key broken / lost ..................143 1.1.1.2 Replace service key ....................143 1.1.1.3 Technical data of the radio module ................143 Handbuch Datafox EVO 2.8 Pure page VI Datum: 18.04.2024 Version: 04.03.21...
  • Page 7 Technical specifications EVO 2.8 /3.5 /5.0 Pure 6.1. communication modules ..................177 6.2. access modules ..................... 177 6.3. Module digital in and out ..................177 6.4. Modules miscellaneous ..................177 Index Handbuch Datafox EVO 2.8 Pure page VII Datum: 18.04.2024 Version: 04.03.21...
  • Page 8: For Your Safety

    For your Safety Safety Information for Datafox Products The EVO 2.8 Pure must only be operated according to the instructions given in the manual. Do no insert any foreign objects into the openings and ports. The device must not be opened. All maintenance work must only be per- formed by authorized specialists.
  • Page 9: Introduction

    GPRS, USB etc. It fulfills all conditions for a flexible usage not only for personnel or order time re- cording but also for further scopes. This constitutes a real added value. The powerful tools Datafox- StudioIV and DLL facilitate quick and easy integration in any IT solutions. Due to scalability, numer- ous options are available.
  • Page 10: Typography Of The Documentation

    Due to technical development, illustrations, function steps, procedures and technical data may vary slightly. The Datafox device has been developed for the purpose of creating a flexible and easily inte- grated terminal for data recording serving for a great variety of applications. The device is robust and easy to use.
  • Page 11 With some practice it will be possible to create a complete compilation for the EVO 2.8 Pure within half an hour. If you need functions that are not available, please contact us. Note:  If you need support for the compilation of setups, we offer you our services. Due to...
  • Page 12: Intended Use And Environmental Protection Regulations And Notices

    In order to ensure maximum battery life, it is recommended to recharge the battery only after com- plete discharge. See respective type label of the device EVO 2.8 Pure. 3.3. Environmental Influences Extreme environmental influences may damage or destroy the device and should be avoided. This includes fire, extreme sunlight, water, extreme cold and extreme heat.
  • Page 13: Mounting Outdoors

    In the case of bell systems / mailboxes / barriers, mount- ing plates are usually already available which can be used for this purpose. View recessed Installation in A front plate / Mounting plate Handbuch Datafox EVO 2.8 Pure page 6 Datum: 18.04.2024 Version: 04.03.21...
  • Page 14: Temperature

    Except for the battery replacement in mobile devices, Datafox devices are maintenance-free and must only be opened by authorized professionals. In case of defects, please contact your dealer or the Datafox service hotline. If a definite defect is present, you can also send the device directly to Datafox. https://www.datafox.de/reparaturen.de.html?file=files/Datafox_Devices/PDF/Support/Data- fox%20Reparaturbegleitformular%20V3%2C%20D-GB_2020.09.25.pdf Handbuch Datafox EVO 2.8 Pure...
  • Page 15: Cleaning

    Also ensure that technical equipment of your vehicle is not compromised by the device. In order to prevent SIM card misuse, have your SIM card blocked immediately in cases of loss or theft of the device. Handbuch Datafox EVO 2.8 Pure page 8 Datum: 18.04.2024 Version: 04.03.21...
  • Page 16: Disposal

    The correct disposal of electrical and electronic equipment protects human life and the environment. For more information regarding the disposal of electrical and electronic equipment, please contact your local authorities or waste disposal companies. Handbuch Datafox EVO 2.8 Pure page 9 Datum: 18.04.2024 Version: 04.03.21...
  • Page 17: System Requirements / Hardware System Structure

    System Requirements / Hardware 4.1. System Structure The system consists of the Datafox device, the DatafoxStudioIV, the communication DLL and a soft- ware for processing the generated data. Create setup Save setup Transfer setup to device DatafoxStudioIV Setup Communication- DLL Software for processing the generated data Handbuch Datafox EVO 2.8 Pure...
  • Page 18: Installation Requirements For Operating Datafox Devices

    4.2. Installation requirements for Operating Datafox Devices In order to operate the Datafox device, you need a 230 V power connection for the Datafox power supply. Depending on the main communication set, you need a corresponding transfer medium or connection cable.
  • Page 19: General Hardware Information

    We currently recommend equipping the devices with a POE module if a "UPS" is to be used. Then connect the devices via a POE switch and supply the switch via a standard UPS. Handbuch Datafox EVO 2.8 Pure page 12...
  • Page 20: Compatibility

    Description The Firmware archive combines device specific firmware files into an archive container. This archive uses the file extension DFZ (abbreviation for Datafox Zip). When uploading firmware to a device through DatafoxSudioIV of the DFCom library, simply use this archive.
  • Page 21: Device Firmware And Device Setup

    With the DatafoxStudioIV, you create a device setup (application program) for the Datafox device. That means that in the setup only those functions were defined which were available in the Datafox- StudioIV version at the time of the setup creation. The DatafoxStudioIV you use for opening a de- vice setup may thus only be newer but never older than the DatafoxStudioIV version you used to create the device setup.
  • Page 22: Update / Downgrade

    When performing a firmware downgrade the firmware has to be transmitted to the device twice. This has technical reasons. Errors shown on the display of the device after the first transfer can be ignored. Handbuch Datafox EVO 2.8 Pure page 15 Datum: 18.04.2024 Version: 04.03.21...
  • Page 23: Device

    On delivery, the device is fully functional and configured with a demo setup so that you can test the input immediately. After establishing the power supply the device will switch on automatically. The EVO 2.8 Pure automatically starts booting, recognition of the hardware options and loading the setup. After having fin- ished booting, the device switches to operation.
  • Page 24: Operation And Display Elements Of The Evo 2.8

    5.2. Operation and display elements of the Evo 2.8 The terminal works with a resistive touch display. display and touch area Reading range of the transponder reader Handbuch Datafox EVO 2.8 Pure page 17 Datum: 18.04.2024 Version: 04.03.21...
  • Page 25: Display And Bios Of The Evo-Line 2.8 Pure

    The entire display area is equipped with a touch screen. Simply tap the tile you want with your finger to select. Date Tile for company logo and status indicator Time The logo can be load to the terminal via Datafox StudioIV under the tile Configuration → Display-Designer tab. 08:45 Tile for „ESC“ if neccessary Mi 26.06.13...
  • Page 26: Structure Of Display Evo 2.8 Pure In The Bios Menu

    5.2.1.2. Structure of display EVO 2.8 Pure in the Bios menu The Bios menu can be accessed by pressing the tile for company logo/status for 2 seconds. Display of status icons: 08:45 Briefly tap the logo to display the status incobs.
  • Page 27 However, the IP assigned by the server is dis- 192.123.123.155 played. Netmask 255.255.255.000 TCP / IP – settings: Set IP: 08:45 192.123.123.155  lan parameters Gateway 192.123.123.1  Port 8000  Handbuch Datafox EVO 2.8 Pure page 20 Datum: 18.04.2024 Version: 04.03.21...
  • Page 28 E.g: - Hitag 2 -> from Segment 4 - Mifare Classic -> from Sector 0 block 1 Otherwise, only the type and version of the transponder reader is shown. Handbuch Datafox EVO 2.8 Pure page 21 Datum: 18.04.2024 Version: 04.03.21...
  • Page 29 To test the touch, simply move the stylus over the display. The respective tile must then change colour to white. If no operation is performed for 7 sec- onds, the calibration test is automatically terminated. Handbuch Datafox EVO 2.8 Pure page 22 Datum: 18.04.2024 Version: 04.03.21...
  • Page 30: Bios Menu Setting Wlan

    Attention: This function is only supported on EVO 2.8 Pure, 3.5 Pure, 3.5 Universal and 4.3. If changes have been made, you will be asked whether they should be saved when you exit the menu. Yes → saves the changes and exits the menu. No → exits the menu without saving the changes.
  • Page 31 SSID can be added. Attention: Currently, however, only the connection to WPA2 networks is supported when entering with SSID. Handbuch Datafox EVO 2.8 Pure page 24 Datum: 18.04.2024 Version: 04.03.21...
  • Page 32 The input of the SSID and the key are limited to 32 characters. Values of the "Latin1" character set are permitted as input, with the exception of the control characters. Handbuch Datafox EVO 2.8 Pure page 25 Datum: 18.04.2024 Version: 04.03.21...
  • Page 33: Setting Of The Proximity- & Ambient Light-Sensor

    -Bios menu -> usersetting-> display /signals-> Proximity- & ambient Light-Sensor Is the Sensor activated, have you this display: no motion detected! motion detected! Sensor is deactivated: The ambient light sensor set automatically the brightness of the display. Handbuch Datafox EVO 2.8 Pure page 26 Datum: 18.04.2024 Version: 04.03.21...
  • Page 34 Information’s: Proximity- & ambient Light -Sensor When a Datafox terminal is not in use, it should be in a low power mode. Display and backlights should be off or only slightly active. This is to save energy, in addition, the life of LED or display back lights is also significantly extended.
  • Page 35 The ambient light sensor controls the brightness of the display independently of the proxim- ity sensor. In bright ambient light, the backlight is operated at the set brightness. In darker surroundings, the value is automatically reduced to 10%. Handbuch Datafox EVO 2.8 Pure page 28 Datum: 18.04.2024 Version: 04.03.21...
  • Page 36: Displaydesigner

    For the devices AE-MasterIV V4, PZE-MasterIV V4 and PZE-MasterIV Basic V4 is the Designer only usable for color display. With the Display-Designer, Datafox offers the possibility for partners and users to customize the dis- play according to your requirements. But due to the necessary operating sequences, this cannot be a completely free design, but things like headlines, menu structures and footers have to be guaran- teed.
  • Page 37: Color Setting For The Display

    „PZE“-design. This design is also set as de- fault when you first create a Function Key’s new theme in Display Designer. are not displayed in the default setting. Handbuch Datafox EVO 2.8 Pure page 30 Datum: 18.04.2024 Version: 04.03.21...
  • Page 38: Display Function Buttons On The Evo 4.3 / 4.6 / 2.8 / 3.5 /5.0 Display

    Upload images for function buttons of EVO 4.3 / 4.6 / 2.8 / 3.5 /5.0 Under this menu item "Key settings" you can import the image file for each function key. Sample picture for the key fig- ures: Handbuch Datafox EVO 2.8 Pure page 31 Datum: 18.04.2024 Version: 04.03.21...
  • Page 39: Transfer Additional Images

    The file names must follow name restrictions as followed: filename - Data storage successful: save_ok.bmp filename - Data storage almost full: save_warning.bmp filename - Data store full! Notify admin: save_error.bmp Handbuch Datafox EVO 2.8 Pure page 32 Datum: 18.04.2024 Version: 04.03.21...
  • Page 40: Image Display In The Main Menu

    The other main menu pages activated in the display designer can still be reached by swiping. Handbuch Datafox EVO 2.8 Pure page 33 Datum: 18.04.2024 Version: 04.03.21...
  • Page 41: Keyboard Graphics A. Touch Config. For The Evo 4.6 Flexkey And 5.0 Pure

    Layout with fox-design white Layout with fox-design black You fount the Immage for the touch in the installation of the DatafoStudioIV: Here the standard installation path: C:\Program Files (x86)\Datafox\data\touch\EVO_5_0 C:\Program Files (x86)\Datafox\data\touch\EVO_4_6 Handbuch Datafox EVO 2.8 Pure page 34 Datum: 18.04.2024 Version: 04.03.21...
  • Page 42: Show Images During Inputs

    With the PZE and AE MasterIV devices, this function is only available in con- junction with a color display. This feature is not possible for EVO 2.8 Pure, EVO 3.5 Pure and EVO 3.5 Universal, otherwise the F-keys for operation could no longer be displayed.
  • Page 43 If these are not referenced in an input field, the images are not displayed either. In this case, note that the available storage space in the terminal is thereby reduced. Handbuch Datafox EVO 2.8 Pure page 36 Datum: 18.04.2024 Version: 04.03.21...
  • Page 44: Design Examples In The Designer

    With the installation of the DatafoxStudioIV you get several design examples for the devices. Click on the "Design Examples" button to open them. Datafox gradually extends the examples. If you have any suggestions or wishes, please let us know. Handbuch Datafox EVO 2.8 Pure page 37 Datum: 18.04.2024 Version: 04.03.21...
  • Page 45: Installation Of The Evo 2.8 / 3.5 /5.0 Pure Terminal

    Installation height from 1.20 to 1.40 m recom- mended. If the device is equipped with a finger scanner, you Depending on the size of the person a Installation height from 1.20 to 1.40 m recom- mended. Handbuch Datafox EVO 2.8 Pure page 38 Datum: 18.04.2024 Version: 04.03.21...
  • Page 46: All Dimensions For The Evo Terminal

    5.3.2. All dimensions for the EVO terminal Here the complete assembly and setup instructions: https://www.datafox.de/d67/unternehmen/downloads/informationsmaterial/evo-3-5-pure/1140x1_Da- tafox_EVO_2.8_3.5_5.0_Pure_Montage_und_Inbetriebnahme.pdf Handbuch Datafox EVO 2.8 Pure page 39 Datum: 18.04.2024 Version: 04.03.21...
  • Page 47: Connecting Of Evo 2.8 /3.5 /5.0 Pure Terminals

    5.4. Connecting of EVO 2.8 /3.5 /5.0 Pure Terminals 5.4.1. Connecting plugs The EVO 2.8 Pure has 5 integrated module places. On this places you can order different modules. You can choose the modules on the pricelist. 12VDC RS232 Connector strip of the EVO 2.8 Pure V4...
  • Page 48: Powersupply Of The Evo 2.8 / 3.5 / 5.0 Pure

    IEEE 802.3af 15,4 Watt 12,95 Watt PoE+ IEEE 802.3at 25,4 Watt 21,90 Watt If power is supplied via POE, an external access-reader can also be supplied via the access control plug. Handbuch Datafox EVO 2.8 Pure page 41 Datum: 18.04.2024 Version: 04.03.21...
  • Page 49: Modules For Devices Of Hardware V4

    5.5.1. Modules for devices of hardware V4 5.5.1.1. Description of the various extension modules The Datafox devices of the generation V4 are particularly distinguished by the variable configuration of individual modules. Depending on the device, a certain number of module locations are available.
  • Page 50 This can be individually fitted. Exceptions: Module place 8, only here TCP is possible. RS 485 for access control - maximum 4 Modules can be fitted. Handbuch Datafox EVO 2.8 Pure page 43 Datum: 18.04.2024 Version: 04.03.21...
  • Page 51: Read Out Important Module Information From The Device

    5.6.1.1. Read out important module information from the device Click on: "Configuration → Device Configuration BIOS" Then click on "Status" thereafter Click "Read". Handbuch Datafox EVO 2.8 Pure page 44 Datum: 18.04.2024 Version: 04.03.21...
  • Page 52 Different timers, which are set in the setup, are shown. The figure in brackets is the actual time to the next trigger. Number of stored records in the device and memory used. Handbuch Datafox EVO 2.8 Pure page 45 Datum: 18.04.2024 Version: 04.03.21...
  • Page 53: Connection Of The Individual Modules

    Analog inputs, 4 x analog IN common ground; GND / Ground + 0-10 V signal 4 + 0-10 V signal 3 + 0-10 V signal 2 + 0-10 V signal 1 Handbuch Datafox EVO 2.8 Pure page 46 Datum: 18.04.2024 Version: 04.03.21...
  • Page 54: X Digital Out

    Connectiom example (Connection of 4 contacts): e.g.: 4x digital in max. 30V 0 - 1,5 V Input logical 0 3,5 V - 30 V Input logical 1 - Galvanically isolated - up to 250Hz Handbuch Datafox EVO 2.8 Pure page 47 Datum: 18.04.2024 Version: 04.03.21...
  • Page 55: X Digital Out Activ-Low (Ground Switched)

    4 x digital OUT aktive-Hi (plus switched) Example connection for indicator lamp, module 51 In this way, the malfunction indicator lamp can be connected with just a single plug. Buzzer blue green Handbuch Datafox EVO 2.8 Pure page 48 Datum: 18.04.2024 Version: 04.03.21...
  • Page 56: Bus For Access Control

    Furthermore, the connection for a digital input and output is available. The pin assignment looks as follows: How the individual access components are connected or wired, can be found in the chapter "Access control" Handbuch Datafox EVO 2.8 Pure page 49 Datum: 18.04.2024 Version: 04.03.21...
  • Page 57: Communication Of Hardware V4 Devices

    The type of communication depends on the device. All possible communications are listed in the device.  Note: Datafox-devices are able to communicate encrypted. Read more in the manual for the „DatafoxStudioIV“. The switching of the communication can be done via : 1.
  • Page 58: Automatic Detected Connected Usb To Pc

    If the device is connected to a PC no other connections (for example Wi-Fi) will happen. If the USB-cable is disconnected, it will automatically switch to the configured main com- munication. Handbuch Datafox EVO 2.8 Pure page 51 Datum: 18.04.2024 Version: 04.03.21...
  • Page 59: Installing Usb Driver For Hardware V4 Devices

    Follow the instructions on the screen: Caution: Only use the driver which are delivered with the device! Note:  If you have DatafoxStudioIV installed, the USB-driver will already be installed on your PC. Handbuch Datafox EVO 2.8 Pure page 52 Datum: 18.04.2024 Version: 04.03.21...
  • Page 60: Communication / Record Transfer Via Usb-Stick (Host)

    Lists of access control can be transferred individually, operation lists must always be transmitted in complete form. All lists defined in the setup must also exist on the stick in the "List" directory. Handbuch Datafox EVO 2.8 Pure page 53 Datum: 18.04.2024 Version: 04.03.21...
  • Page 61: Error Messages By Using Usb-Stick (Host)

    Error by checking the handle, the file is not open Error write protect Error by the record structure Error during the firmware update No USB stick Incorrect password No list Handbuch Datafox EVO 2.8 Pure page 54 Datum: 18.04.2024 Version: 04.03.21...
  • Page 62: Communication Via Tcp / Ip

    → "LAN / WLAN – Configuration (*.df0)“. The LAN / WLAN configurations are saved in a file with the filename extension "*. df0". Here you have the possibility to edit the file, load it into the Datafox device (upload) or read it from the device (download).
  • Page 63: Communication Tcp / Ip Via Network-Cable

    For devices with display, the IP address can also be entered directly on the device. Press ESC and ENTER simultaneously to enter the Bios menu of the device. More information can be found in the chapter „bios menu“. Handbuch Datafox EVO 2.8 Pure page 56 Datum: 18.04.2024 Version: 04.03.21...
  • Page 64: Communication Tcp / Ip Via Wlan / Wifi

    Communication TCP / IP via wLAN / Wifi General information about the WLAN modules used. There are 2 different WLAN modules that have been integrated into the Datafox devices. 1.) Redpine – installed in the units since 2013. 2.) Texas Instruments TI-CC3135 - installed in the devices since 2021.03.
  • Page 65: M111_Wlan Esp32-C3 Ml01 (Wlan-Modul Df-Wl03)

    Es ist lediglich der KEY einzugeben. Achtung: Wir können nicht jeden auf dem Markt befindlichen Acsess-Point Testen. Daher ist es uns nicht möglich, einen Verbindungsaufbau zu jedem AP zu garantieren. Handbuch Datafox EVO 2.8 Pure page 58 Datum: 18.04.2024 Version: 04.03.21...
  • Page 66: Texas Instruments Ti-Cc3135 (Generation 2)

    We cannot test every Acsess point on the market. Therefore, it is not possible for us to guarantee a connection to every AP.. Support for WPA3 and WPA2 Enterprise is planned. Handbuch Datafox EVO 2.8 Pure page 59 Datum: 18.04.2024 Version: 04.03.21...
  • Page 67: Redpine (Generation 1)

    When setting the encryption AES or WEP, only one type is used at a time. The setting AES+WEP means for some access points that AES encryption is performed first and then additionally encrypted with WEP. In this case, only set AES. Handbuch Datafox EVO 2.8 Pure page 60 Datum: 18.04.2024 Version: 04.03.21...
  • Page 68 WLAN connection. The user therefore has no insight into the dial-in parameters at the various locations.  Hint: With automatic selection of the configuration / location, the first attempt is always made to establish a connection with the default schema. Handbuch Datafox EVO 2.8 Pure page 61 Datum: 18.04.2024 Version: 04.03.21...
  • Page 69: Connection Of The Terminals Via Tcp/Ip Dns / Dhcp

    5.7.3.6. Connection of the Terminals via TCP/IP DNS / DHCP To connect a Datafox EVO-Device with the Hostname it is necessary to set something in the DNS- Server. (In this example Windows-Server 2012) Create a new Host (A)-value: Abbreviation Descripion...
  • Page 70 DHCP- entry EVO 2.5 10245 .zentrale.de Evo25-10245.zentrale.de EVO 3.5 10246 .zentrale.de Evo35-10246.zentrale.de AE-Master 10247 .zentrale.de AE-10247.zentrale.de PZE-Master 10248 .zentrale.de PZE-10248.zentrale.de EVO 4.3 10249 .zentrale.de Evo43-10249.zentrale.de Handbuch Datafox EVO 2.8 Pure page 63 Datum: 18.04.2024 Version: 04.03.21...
  • Page 71: Communication Via Rs485

    Setting for communication in the DatafoxStudioIV for connection via RS 485: Com-Port See in the device man- ager on your PC Baud rate 38400 and Bus number are to set in the device bios menu Handbuch Datafox EVO 2.8 Pure page 64 Datum: 18.04.2024 Version: 04.03.21...
  • Page 72: Connecting The Terminal Via Rs485 With A Comserver Lantronix

    Setting for communication in the DatafoxStudioIV for connection via RS 485: IP and Port must set in the comserver. Baud rate 38400 and Bus number are to set in the device bios menu Handbuch Datafox EVO 2.8 Pure page 65 Datum: 18.04.2024 Version: 04.03.21...
  • Page 73 Setting in the Comserver for connection via RS 485: Port: for example 8000 IP: for example 192.168.123.224 Handbuch Datafox EVO 2.8 Pure page 66 Datum: 18.04.2024 Version: 04.03.21...
  • Page 74: Communication Via Cellular Network (Gprs)

    5.7.5. Communication via Cellular Network (GPRS) The EVO 2.8 Pure can be equipped with a cellular network modem. It enables the communication via cellular network. The antenna is located in the connection compartment of the device and can optionally be replaced by an external antenna if reception is bad.
  • Page 75: Communication State In The Display

    Device is the encryption active, but not on the server battery is down, to disable Modem. impossible connect to the provider or Roaming impossible close connection Turn modem off Handbuch Datafox EVO 2.8 Pure page 68 Datum: 18.04.2024 Version: 04.03.21...
  • Page 76: Communication Via Sms

    5.7.6. Communication via SMS 5.7.6.1. Send a SMS With the EVO 2.8 Pure, it's possible to send a SMS. Condition for this is, an integrated GPRS-Mo- dem (communication via Cellular Network). The main communication must be set on GSM or GPRS/GSM.
  • Page 77: Receive A Sms

    (default setting). Save you an empty Key, then receive the device every SMS. The last received SMS can you see in the Bios-Menu under „general information Bios (Menu)“. Handbuch Datafox EVO 2.8 Pure page 70 Datum: 18.04.2024 Version: 04.03.21...
  • Page 78 Connection to the server with the saved parameters in the „active mode“. b) and c) Connection on Port 8000 to the server (www.datafox.de/123.123.123.123). d) Connection to the server “www.datafox.de” and port “4711”. Handbuch Datafox EVO 2.8 Pure page 71 Datum: 18.04.2024 Version: 04.03.21...
  • Page 79 If the level of regulation from the system is not correct, then there is a report via SMS. The Datafox MasterIV is not the regulator here. He gives only a report in trouble. If necessary, a procedure also can be done.
  • Page 80: Connection And Wiring Of The Access Control

    When adding comments, you have to notice that in a comment line no field values can be given and that the comment line has to start with a semicolon. The table Reader.txt might look like this: RefLocation RefAction PinGeneral Handbuch Datafox EVO 2.8 Pure page 73 Datum: 18.04.2024 Version: 04.03.21...
  • Page 81 Online / offline after time-out is a combination. If the server is unavailable, the terminal can decide on basis of its lists whether to grant access to a per- son or not. Handbuch Datafox EVO 2.8 Pure page 74 Datum: 18.04.2024 Version: 04.03.21...
  • Page 82: Description Of Tables For Access Control 2

    Description of Tables for Access Control 2 Table Reader (List of all devices installed in the system) Name Data type Length Description Number Unique Key (value>0) of the Reader table. (int) Handbuch Datafox EVO 2.8 Pure page 75 Datum: 18.04.2024 Version: 04.03.21...
  • Page 83 6 = permanent opening for U & Z cylinders 7 = Burglary alarm system, allowed to switch on/off 8 = general authority (with PIN request) 9 = general authority (no PIN request) Handbuch Datafox EVO 2.8 Pure page 76 Datum: 18.04.2024 Version: 04.03.21...
  • Page 84 Reference to the action that should be carried out (e.g. switch relay). RefAction (int) The time model which indicates when the digital input is checked. (0 = not Number RefTime used). (int) Handbuch Datafox EVO 2.8 Pure page 77 Datum: 18.04.2024 Version: 04.03.21...
  • Page 85 This is a function to switch relays directly via time (table) RefTime (int) Please not mix this function with the normal access actions. !!! By a time-table setting “1234567 00:00-23:59” is the relay permanent on. Handbuch Datafox EVO 2.8 Pure page 78 Datum: 18.04.2024 Version: 04.03.21...
  • Page 86: Access-Control With Intera 2

    RFID-Tac in the field LED – white = sleepmode (deactivatet via proximity sensor.) LED – off -> reddy to read and the background LED is on. LED – Blau (no function) Handbuch Datafox EVO 2.8 Pure page 79 Datum: 18.04.2024 Version: 04.03.21...
  • Page 87 Connection to the PTSM connector The EVO Intera II is supplied with the 4-pin or 5-pin mating connector for connecting the reader. These are protected against polarity reversal and are sup- plied by Datafox with printed assignment. PTSM 5- PTSM 4- DIP switch...
  • Page 88 Bus Nr. 1 EVO-ZK-Leser Uv >max. 200 m bei 0.6mm plug 4 poles for access plug 5 poles digital in-/output max. 30V; 2A Power supply for door electic door opener Handbuch Datafox EVO 2.8 Pure page 81 Datum: 18.04.2024 Version: 04.03.21...
  • Page 89: Evo Intera Ii, Individual Settings

    5.8.2.1. EVO Intera II, Individual settings The mask for setting the EVO Intera II configuration can be accessed in the Datafox Studio via the configuration menu: The mask allows setting / adapting the behavior of the EVO Intera II. These settings are divided into 3 areas: •...
  • Page 90: Global Function

    The reader can adjust its brightness - e.g. in order not to shine too brightly at night - to the bright- ness of the surroundings. If this function is desired, activate the ambient light sensor. Handbuch Datafox EVO 2.8 Pure page 83...
  • Page 91: Settings For Standby

    In this operating mode, the 3 LEDs can be assigned functions that differ from the normal operating mode. In addition, the Datafox Active Light can be switched if it is built into the reader.
  • Page 92: Preview Of Reader Behavior

    To transfer to or from a reader, please connect it to your PC via USB. After pressing one of the but- tons for transfer, you will see the file transfer dialog of the Datafox Studio: Here you can select the configuration file to be transferred - the version opened in the editor is the standard assignment of the transfer dialog via the transfer button to the device.
  • Page 93: Access Control Ii With Phg-Modules

    Here for 5 of the max. 6 keys can be used in the setup. Attention: Technical data for the PHG access modules can be found on the Datafox DVD or in our download area. Please note the power consumption of the modules and the voltage drop at long cable lengths.
  • Page 94: Connecting Of Phg-Reader

    5.8.3.1. Connecting of PHG-reader In order to connect the PHG modules, please note the PHG documentation on the Datafox CD: <Datafox-Geräte- Datafox-Zutritt-Module PHG *.pdf> In the PHG documents for the single modules, the pin assignment and configuration via the DIP switches are described.
  • Page 95 RS485 I²C max. 1000 m max. 5 m floating relay contact Reader I/O-Box Power supply 12 V DC for reader C max. 5m ISTY 2x2x0,8  / – / Handbuch Datafox EVO 2.8 Pure page 88 Datum: 18.04.2024 Version: 04.03.21...
  • Page 96 Power supply for door opener Bus Nr. 1 Siedle-access reader Wire plan for Siedle access reader: Power supply 12 V DC for reader max. 30V; 2A Power supply for door opener Handbuch Datafox EVO 2.8 Pure page 89 Datum: 18.04.2024 Version: 04.03.21...
  • Page 97 Wiring plan for a VOXIO-T-Z reader: The reader type is supported as of FW 04.03.12.xx PHG reader VOXIO-T-Z Power supply 12 V for DC AC-reader max. 30V; 2A Power supply for door opener Handbuch Datafox EVO 2.8 Pure page 90 Datum: 18.04.2024 Version: 04.03.21...
  • Page 98 RS485 I²C max. 5 Reader 3 potential-free contact for door more reader Last reader last reader end resistor max. 1000 m switch 7 → on Handbuch Datafox EVO 2.8 Pure page 91 Datum: 18.04.2024 Version: 04.03.21...
  • Page 99 – / ~ further reader In any case, a protection circuit should be integrated when connecting the door-opener. A freewheeling diode for DC and an RC element for AC. Handbuch Datafox EVO 2.8 Pure page 92 Datum: 18.04.2024 Version: 04.03.21...
  • Page 100 Relais 2 normally open free free digital in 2 Signal digital in 2 ground 1 und 2 ground U+ 8…..30V ST 1 Circuit diagram “S“ normally open “G“ common “Ö“ normally close Handbuch Datafox EVO 2.8 Pure page 93 Datum: 18.04.2024 Version: 04.03.21...
  • Page 101: Configuration

    The IO box is accessed via the same address like the reader. The two digital in- puts have port number 4 and 5, the digital outputs port number 1 and 2. In case of discontinuity or sabotage, port no. 6 is used. Handbuch Datafox EVO 2.8 Pure page 94 Datum: 18.04.2024 Version: 04.03.21...
  • Page 102 C bus, is omitted. Corresponding reader table: RefLocation RefAction PinGeneral Description Master device Reader at RS485 (PHG) IO-Box at I C-Bus Reader at RS485 (LTM) IO-Box at I C-Bus Handbuch Datafox EVO 2.8 Pure page 95 Datum: 18.04.2024 Version: 04.03.21...
  • Page 103: Access Control With Evo Intera Reader

    -20 ° C to +70 ° C, IP65 Transponder systems 125kHz Mifare Legic Hitag 1+2+S Mifare Classic Legic prime Unique EM4102 Mifare Desfire Legic advant Titan EM4450 Mifare Ultralight Handbuch Datafox EVO 2.8 Pure page 96 Datum: 18.04.2024 Version: 04.03.21...
  • Page 104 3, without terminate resistor 0-0-0-1-1 Connector for IO- module Relay + digital in description Number. +10V bis +30V DC ! new RS 485-Data „B“ DIP-switch RS 485-Data „A“ GND ground Handbuch Datafox EVO 2.8 Pure page 97 Datum: 18.04.2024 Version: 04.03.21...
  • Page 105: Connecting Of The Evo Intera Reader Examples

    5.8.4.1. Connecting of the EVO Intera reader examples Cable plan for one door, 1 Relay in the EVO 2.8 Pure: Bus Nr. 1 RS 485 ZK Bus-ID 1 TCP / IP (LAN) 12V vom Master Türöffner Relais 1 der ZK-Box Bus Nr.
  • Page 106: Access Control Ii With Evo Agera

    RGB colours. The control of the LED is con- trolled exclusively by the readers firmware. Access denied = red - Access permitted = green - Bios activated = blue - Handbuch Datafox EVO 2.8 Pure page 99 Datum: 18.04.2024 Version: 04.03.21...
  • Page 107: Display For State Of Access Control

    Error message error communication The reader is in constant communi- cation with the master. If communication is interrupted, this is indicated by the text "Communi- cation error" on the reader. Handbuch Datafox EVO 2.8 Pure page 100 Datum: 18.04.2024 Version: 04.03.21...
  • Page 108: Bios-Menu

    The following information can be called up in the general con- figuration: - Installed firmware, serial number - Memory allocation for the image memory - Transponder test for the transponder configured in the mas- ter setup. Handbuch Datafox EVO 2.8 Pure page 101 Datum: 18.04.2024 Version: 04.03.21...
  • Page 109: Display Configuration

    The bus terminating resistor of 120 Ω is switched on or off in the bus configuration under "Terminating resistor". Note: If it is the last or only reader in the RS485 bus, the termi- nating resistor must be switched on. Handbuch Datafox EVO 2.8 Pure page 102 Datum: 18.04.2024 Version: 04.03.21...
  • Page 110: Online Functions For The Access Control

    With the answer from the server you are able to perform specific actions with the access readers. The following examples will give you an insight in what is possible with the functions and actions. All parameters correspond the online functions with the dll. Handbuch Datafox EVO 2.8 Pure page 103 Datum: 18.04.2024 Version: 04.03.21...
  • Page 111 For this, the new keywords "module" and "master" were implemented. These must be used to- gether, replacing the keyword "access". Attention: The order “access→mask→typ→duration” or master→module→mask→typ→dura- tion must be strictly adhered to. status=ok&checksum=2482&access=010&mask=5&type=1&duration=2 status=ok&checksum=2482&master=1&module=010&mask=5&type=1&duration=2 Handbuch Datafox EVO 2.8 Pure page 104 Datum: 18.04.2024 Version: 04.03.21...
  • Page 112 You can also perform multiple actions on the access control in one response. However, the total length of the response must not exceed 254 characters. Attention: A automated switch between online and offline mode is not possible in http mode Handbuch Datafox EVO 2.8 Pure page 105 Datum: 18.04.2024 Version: 04.03.21...
  • Page 113: Online Via Dll Connection

    LEDs. More dll functions are documented in the “Datafox SDK” on our website https://www.datafox.de/downloads-datafox-kyo-inloc.de.html?file=files/Datafox_Devices/Down- loads_Geraete_Zubehoer/001_MasterIV-Software/Datafox_SDK_Windows_04.03.12.zip...
  • Page 114: Function Extention For Access Control Ii

    The entire logic of the access control lies in the links between the access lists. Here is an overview of the links between the access lists: The following example gives an overview: Handbuch Datafox EVO 2.8 Pure page 107 Datum: 18.04.2024 Version: 04.03.21...
  • Page 115: Examples

    All readings of RFID on this reader make all actions in the table “action“, with the ID 3000. Table Time Weekdays TimeStart TimeEnd Description text 1234567 00:01 23:59 24houers opening possible 1234567 07:00 16:00 Time for special action Handbuch Datafox EVO 2.8 Pure page 108 Datum: 18.04.2024 Version: 04.03.21...
  • Page 116 Description 1111 2005-01-01 2015-12-31 Master of Garage 2222 2005-01-01 2015-12-31 Skilled workers 3333 2005-01-01 2015-12-31 Facility manager Facility manager second RFID-chip, 4444 2005-01-01 2015-12-31 only for closing the door Handbuch Datafox EVO 2.8 Pure page 109 Datum: 18.04.2024 Version: 04.03.21...
  • Page 117 The goal is to allow users only to exit at the allowed floor. Then tenant uses the transponder to activate only the switch for his floor. In the cabin of the elevator the RFID-reader is installed. The Datafox-Device is on the top of the cabin.
  • Page 118 2099-12-31 floor Tenant of an apartment on the 1102 2005-01-01 2099-12-31 floor 1 and 2 Tenant of an apartment on the 1104 2005-01-01 2099-12-31 floor 1, 2 and 3 Handbuch Datafox EVO 2.8 Pure page 111 Datum: 18.04.2024 Version: 04.03.21...
  • Page 119: Description Of The Table „Action2

    If you would like to continue working with the "action" table, the table "Action 2" may not be transferred to the device. A table "Action 2" has already been transferred to the device, it must be cleared by load- ing a new setup. Handbuch Datafox EVO 2.8 Pure page 112 Datum: 18.04.2024 Version: 04.03.21...
  • Page 120: Additional Functions For Access Control

    Here you can choose whether the reject is limited in time or whether Hard remains active. In the case of Hard Active, access is not permitted again until another room ID has been accessed. This corresponds to leaving the previous room. Handbuch Datafox EVO 2.8 Pure page 113 Datum: 18.04.2024 Version: 04.03.21...
  • Page 121: List Presence

    Reference to the ID of the room, defined in the table "Location", where this RefLocation (int) person currently stays Number Time stamp when the person entered the current room TimeStamp (int) Integer in seconds, starting 01.01.2000. Handbuch Datafox EVO 2.8 Pure page 114 Datum: 18.04.2024 Version: 04.03.21...
  • Page 122: Integration Of A Burglar Detection System (Bds)

    / deactivating the BDS sections. Finally the PIN read- ers will have to associate to one or more BDS sections. The sequence of the entries inside the “ReaderProps” list does not matter. Handbuch Datafox EVO 2.8 Pure page 115 Datum: 18.04.2024 Version: 04.03.21...
  • Page 123: Relays And Digital Inputs For Controlling The Bds (Type 2)

    OutArmPort. If the relay then is closed, the BDS is meant to be armed, the opened relay indicates the disarmed BDS. If no digital input is set as „InRdyRead“, the BDS is considered to be ready to be armed any time. Handbuch Datafox EVO 2.8 Pure page 116 Datum: 18.04.2024 Version: 04.03.21...
  • Page 124: Assigning Codes For Arming And Disarming (Type 3)

    “0” would be a valid code. Please ensure that no operating code is used more than once – the system behav- iour is not defined then. Handbuch Datafox EVO 2.8 Pure page 117 Datum: 18.04.2024 Version: 04.03.21...
  • Page 125: Associating Bds Sections To Readers (Type 4)

    A reader may be part of more than one BDS section. Every section requires an en- try inside the list ReaderProps. Readers not associated to any BDS section may be used to gain access any time using the normal access control rules. Handbuch Datafox EVO 2.8 Pure page 118 Datum: 18.04.2024 Version: 04.03.21...
  • Page 126: Privileging Transponders To Control The Bds

    Examplefor the table Identification: The RFID-Number 59780 can switch the BDS-System and have standard access. Group Duress ActiveStart ActiveEnd ActiveGeneral 51044 2018-01-01 2099-12-31 59780 2018-01-01 2099-12-31 59780 2018-01-01 2099-12-31 Handbuch Datafox EVO 2.8 Pure page 119 Datum: 18.04.2024 Version: 04.03.21...
  • Page 127: Statuscodes

    The PIN entered does not match the stored one. The PIN entered matches the stored one. Timeout while waiting for the PIN to be entered. This status code contains the BDS section [1..5] as property „ID number“. Handbuch Datafox EVO 2.8 Pure page 120 Datum: 18.04.2024 Version: 04.03.21...
  • Page 128: Pre-Checked Online Processing Graph

    5.8.8.7. Pre-checked online processing graph Handbuch Datafox EVO 2.8 Pure page 121 Datum: 18.04.2024 Version: 04.03.21...
  • Page 129: Example For The Bds Integration

    Examplefor the table Identification: The RFID-Number 59780 can switch the BDS-System and have standard access. Group Duress ActiveStart ActiveEnd ActiveGeneral 51044 2018-01-01 2099-12-31 59780 2018-01-01 2099-12-31 59780 2018-01-01 2099-12-31 Handbuch Datafox EVO 2.8 Pure page 122 Datum: 18.04.2024 Version: 04.03.21...
  • Page 130: Automatic Relay Release Upon Opening Of The Door

    Doors that are opened by a time model or set to free access will remain opened. Caution: All action entries associated to the reader will be checked and released. A check con- cerning the group is not implemented. Handbuch Datafox EVO 2.8 Pure page 123 Datum: 18.04.2024 Version: 04.03.21...
  • Page 131: Configuration

    5.8.9.2. Configuration Implementing supervised door using the Datafox Access Control modules requires the setup using the ReaderProps list. This list is required for BDS and anti-passback as well. The following specifi- cation of the ReaderProps thus contains minimal field length specifications.
  • Page 132: Special Case: Relays Operated By Time Model

    ID 10 identified an RFID transponder that is allowed to open the door. The action sets relay 1 at the access controller for 10 seconds. Simultaneously the green LED is activated at reader ID 10. Action2.txt Grou Reader PortOut Elapse Reader Time Time Relais Relais Handbuch Datafox EVO 2.8 Pure page 125 Datum: 18.04.2024 Version: 04.03.21...
  • Page 133: Additional Lists

    If digital input 1 changes to low voltage, all doors being unlocked for a finite time will be locked again. The entry to the ReaderProps list is as follows: ReaderPorps.txt RefReader Type Mode RefReaderInput Input Handbuch Datafox EVO 2.8 Pure page 126 Datum: 18.04.2024 Version: 04.03.21...
  • Page 134: Status Messages Of The Access Control

    Make Action closing Free access on this reader Permanent blocked access Online-result from the server, no access allowed The server rejects the preliminary test The server agrees with the preliminary check Handbuch Datafox EVO 2.8 Pure page 127 Datum: 18.04.2024 Version: 04.03.21...
  • Page 135 5 is for the time ELAPSE, HIGH. 55 # digital output 6 is low (Off). 56 # digital output 6 is HIGH.(On). 57 # digital output 6 is for the time ELAPSE, HIGH. Handbuch Datafox EVO 2.8 Pure page 128 Datum: 18.04.2024 Version: 04.03.21...
  • Page 136 21 is for the time ELAPSE, HIGH.. 315# digital output 22 is low (Off). 316# digital output 22 is HIGH.(On). 317# digital output 22 is for the time ELAPSE, HIGH.. Handbuch Datafox EVO 2.8 Pure page 129 Datum: 18.04.2024 Version: 04.03.21...
  • Page 137 The PIN entered matches the stored one. Timeout while waiting for the PIN to be entered. 1) This status code contains the BDS section [1..5] as property „ID number“. Handbuch Datafox EVO 2.8 Pure page 130 Datum: 18.04.2024 Version: 04.03.21...
  • Page 138 2 alarm-input 3 alarm-input 4 alarm-input 1 alarm-input 6 220# alarm-input 7 221# alarm-input 8 _______ _____ continuously until: 245# alarm-input 32 for new devices hardware version 4 Handbuch Datafox EVO 2.8 Pure page 131 Datum: 18.04.2024 Version: 04.03.21...
  • Page 139: State Signals Of Reader Modules Via Leds

    The lists of the access master are updated on (ca. 1 s) Configuration error via the access lists (Checking of the on 3 x short status messages necessary.) flash Signals readable card in the area, Handbuch Datafox EVO 2.8 Pure page 132 Datum: 18.04.2024 Version: 04.03.21...
  • Page 140: Function For Access Control U&Z (Locking Cylinders)

    Function for access control U&Z (locking cylinders) 5.8.12.1. Design example The radio locking cylinders are set up and integrated via the standard Datafox access control sys- tem. The PHG crypt protocol is used. All data is thus securely encrypted. Functionality: The electronic locking systems read an RFID chip / card and transmit the read information to Data- fox access control.
  • Page 141 9 poles operating voltage KYO-Cenloc 8 - 12 V DC 8 – 10 V AC 0 V - / ~ plug 10 poles KYO-Oneloc plug 4 polig KYO-Fourloc Handbuch Datafox EVO 2.8 Pure page 134 Datum: 18.04.2024 Version: 04.03.21...
  • Page 142 ; 3A Plug 9 poles KYO-Cenloc plug 10 poles KYO-Oneloc function plug 4 poles KYO-Fourloc RS 485 - A RS 485 - B Operation voltage 5 - 24 V DC Handbuch Datafox EVO 2.8 Pure page 135 Datum: 18.04.2024 Version: 04.03.21...
  • Page 143: First Start With Locking Cylinders

    2) The knob module is mounted in the cylinder housing by inserting and simultaneously rotating it. (A+B) 3) To reset the disassembly mode, hold the disassembly card or an authorized transponder in front of the knob module. (C) Handbuch Datafox EVO 2.8 Pure page 136 Datum: 18.04.2024 Version: 04.03.21...
  • Page 144: Set Up The Wireless Network For Cylinder

    Teach out: The cylinder is removed from the FSM and can be taught in to another FSM. • Teach-in: To connect a radio lock cylinder to the FSM (the radio lock cylinder then only communicates with this FSM) Handbuch Datafox EVO 2.8 Pure page 137 Datum: 18.04.2024 Version: 04.03.21...
  • Page 145: Battery State And Live Time

    Battery status of the radio lock cylinders in phase 2 Battery status of the radio lock cylinders in phase 3 (empty) Radio lock cylinder set to battery change mode Handbuch Datafox EVO 2.8 Pure page 138 Datum: 18.04.2024 Version: 04.03.21...
  • Page 146: Change The Access Control Master Id And Knob Active Time

    Active Time is active. Useful values are between 2 and 10 seconds. By default, this time is set to 3 seconds. It makes sense to increase the value if three or more radio participants are connected to a radio module. Recommendation: KnobActiveTime = 6 seconds Handbuch Datafox EVO 2.8 Pure page 139 Datum: 18.04.2024 Version: 04.03.21...
  • Page 147: Optical And Acoustic Signals Of The U&Z Locking Cylinder

    (out of range)  short  short  = = red flashing red lights up  = = green flashing green lights up = long low tone = short beep Handbuch Datafox EVO 2.8 Pure page 140 Datum: 18.04.2024 Version: 04.03.21...
  • Page 148: Optical And Acoustic Signals Of The U&Z Door Handle

    3.) The existing badges can then be re-learned as de- scribed in section 9.1. Here, the first ID card held is used for the battery change card and the second to the disassem- bly card. Handbuch Datafox EVO 2.8 Pure page 141 Datum: 18.04.2024 Version: 04.03.21...
  • Page 149: Supported Transponder Technologies

    - read UID - Read file (max. 220Byte) Not supported is - Random UID (Read true UID at Random UID badges) Legic Prime and Legic Advant currently no restrictions are known. Handbuch Datafox EVO 2.8 Pure page 142 Datum: 18.04.2024 Version: 04.03.21...
  • Page 150: Service Key Broken / Lost

    Indoor and outdoor areas (depending on the Supply voltage: 8-20V= or 8-16 V~ product design). Power consumption: Typ. 10mA (standby), max. 50mA (send/re- Avoid shading! ceive) When used outdoors, the external conditions must be checked. Handbuch Datafox EVO 2.8 Pure page 143 Datum: 18.04.2024 Version: 04.03.21...
  • Page 151: Rfid Reader

    5.9. RFID Reader The RFID reader is built-in the EVO 2.8 Pure If this option is available, see the type label and the label on the backside. By DatafoxStudioIV you can enable the RFID reader. For more information see the manual of DatafoxStudioIV.
  • Page 152: Data On Card

    Franz Zufall 3031323334353637383941424344454630 …… The terminal stores where the data is written to the ID card (e.g. segment) Doors with electronic locking cylinder or similar. Current authorization yes / no Handbuch Datafox EVO 2.8 Pure page 145 Datum: 18.04.2024 Version: 04.03.21...
  • Page 153: Settings For Using Dataoncard

    When importing via the DLL, the data needs to be passed on as binary data. Using the DFC GetField, DFC GetField list functions, you are working with strings, while the firm- ware converts the hexstrings to and from the binary data. Handbuch Datafox EVO 2.8 Pure page 146 Datum: 18.04.2024 Version: 04.03.21...
  • Page 154 1. ) RFID Configurations for the RFID reader The transponder configuration for the reading can be freely selected. However, firstly it needs to be defined in the basic transponder settings. Handbuch Datafox EVO 2.8 Pure page 147 Datum: 18.04.2024 Version: 04.03.21...
  • Page 155  Please note: First, complete the transponder configuration, then create the list with the binary field and finally parameterize the field function Data on Card. Handbuch Datafox EVO 2.8 Pure page 148 Datum: 18.04.2024 Version: 04.03.21...
  • Page 156 0x30, 0x31, 0x32, 0x33, 0x34 ……  Please note: When a 3-tone sequence is signaled, the Data-On-Card option is not available on this de- vice. The option has to be purchased afterwards. Handbuch Datafox EVO 2.8 Pure page 149 Datum: 18.04.2024 Version: 04.03.21...
  • Page 157: Dataoncard On The Access Control Reader

    Only one access control reader (ZK) can be connected to the bus at any time. Dip switch 1 and the termination of the bus must be set to "ON" (Bus address 1). Handbuch Datafox EVO 2.8 Pure page 150 Datum: 18.04.2024 Version: 04.03.21...
  • Page 158: Dataoncard And A Access Control Reader - Wiring

    5.10.4. DataOnCard and a access control reader - wiring Handbuch Datafox EVO 2.8 Pure page 151 Datum: 18.04.2024 Version: 04.03.21...
  • Page 159: Barcode Reader

    5.11. Barcode Reader You can use a internal barcodereader 2d or 3d and you can connect any barcode reader with a RS232 port to the EVO 2.8 Pure. Observe the following pin assignment of the RS232 interface. 12VDC RS232 Function...
  • Page 160 Cable attachment of the barcode reader: Place the cable of the bar- code reader in the wall bracket approximately in this way or fix the cable with a ca- ble tie. Handbuch Datafox EVO 2.8 Pure page 153 Datum: 18.04.2024 Version: 04.03.21...
  • Page 161: Fingerscanner Optical Sensor

    In addition, Finger Writing on Card can be active. You can select the in- dividual menu items! You can also watch the handling of the new finger sensor in our video. https://www.datafox.de/video-verwendung-und-einlernen-einer-fingerprintloesung-mit-optischen-flaechensensor.de.html Handbuch Datafox EVO 2.8 Pure page 154 Datum: 18.04.2024 Version: 04.03.21...
  • Page 162: Menu Page - Check Finger

    The successful teach-in is indicated by a green field which also contains a quality value. With a quality value of 85 and more, the teach-in was very successful. Handbuch Datafox EVO 2.8 Pure page 155 Datum: 18.04.2024 Version: 04.03.21...
  • Page 163: Training" Menu Page

    If no more green feedback comes, the training can be stopped. The fingers that have already been taught-in are marked with „X“ Handbuch Datafox EVO 2.8 Pure page 156 Datum: 18.04.2024 Version: 04.03.21...
  • Page 164: Menu Page - Delete

    For EVO 2.8 and 3.5 there is a separate page for exiting the finger administration menu. Simply click on the center of the screen and exit the menu. With the EVO 4.3 you can exit the administration menu by pressing the "ESC" key. Handbuch Datafox EVO 2.8 Pure page 157 Datum: 18.04.2024 Version: 04.03.21...
  • Page 165 Schlechte Positionen / Bad positions Zu weit unten Zu weit oben Zu weit links Zu weit rechts Too far down Too far up Too far left Too far right Handbuch Datafox EVO 2.8 Pure page 158 Datum: 18.04.2024 Version: 04.03.21...
  • Page 166 Finger sehr trocken Trockenen Finger kurz Trockenen Finger an- Trockenen Finger ein- Finger very dry gerieben gehaucht gecremt Dry finger shortly Dry finger breathed on Dry finger with cream rubbed Handbuch Datafox EVO 2.8 Pure page 159 Datum: 18.04.2024 Version: 04.03.21...
  • Page 167 640 Bytes. ISO19794-4; ANSI-378 Resolution 500 dpi The sensor-resolution is 500 dpi. Active area 14 x 18mm The active area of the sensor is 14 x 18 mm. Handbuch Datafox EVO 2.8 Pure page 160 Datum: 18.04.2024 Version: 04.03.21...
  • Page 168: Operation Finger Scanner Line Sensor

    In no case may be components on the finger, which have an abrasive effect. These use the protective layer of the line sensor and thus significantly reduce the service life. Handbuch Datafox EVO 2.8 Pure page 161 Datum: 18.04.2024 Version: 04.03.21...
  • Page 169: General Infomation

    61.00, the image quality must necessarily be less than 70. The recommended value of 40 offers an optimum for learning the fingers.  Note: Recoment settings: Security level 60%, quality: 40% minimum of minutien: Handbuch Datafox EVO 2.8 Pure page 162 Datum: 18.04.2024 Version: 04.03.21...
  • Page 170 The behavior must be checked in each individual case, since it is very dependent on the group of people. In such cases, one should switch to another finger, because not every human finger is suitable for the Minutien method. Handbuch Datafox EVO 2.8 Pure page 163 Datum: 18.04.2024 Version: 04.03.21...
  • Page 171: Teach-In

    05597861113494 M. Musterfrau Step 2 Scan finger Step 3 PID and finger characteristics to combinate finger characteristics Template Step 4 Save Template on Biokey-Module on Mifare Transponder on Server Handbuch Datafox EVO 2.8 Pure page 164 Datum: 18.04.2024 Version: 04.03.21...
  • Page 172: Procedure

    (scanned) finger. The fingerprint module transfers PID and validity to the terminal. The task in the terminal for the fingerprint triggers an input sequence and access control - if defined in the setup. Handbuch Datafox EVO 2.8 Pure page 165 Datum: 18.04.2024 Version: 04.03.21...
  • Page 173: Process Variants

    Deleting a template from a fingerprint module by identification 1.) Scan finger 2.) Delete template from fingerprint module or 1.) Determine PID (read from ID card or via list selection) 2.) Delete template from fingerprint module Handbuch Datafox EVO 2.8 Pure page 166 Datum: 18.04.2024 Version: 04.03.21...
  • Page 174: Technical Data Of The Fingerprint Module

    Experience shows that not for all employees the fingers can be recorded in sufficient quality. o Depends on the state of the fingers. For those persons the ID card or PIN has to be recorded. Handbuch Datafox EVO 2.8 Pure page 167...
  • Page 175: Fever Measurement On The Wrist

    5.14. Fever measurement on the wrist The temperature measurement option on Datafox terminals measures the skin temperature behind the wrist at a distance of 3-10 cm. This measurement can give an indication of whether the person at the terminal may have a fever. Fever is often an early sign of contagious infectious diseases, as it is the case with Covid-19.
  • Page 176: Operating Sequence Of The Measuring Process

    (e.g. green or red light). The value of the result status can be assigned to a record description field or also to a "global varia- ble" for a subsequent evaluation. Handbuch Datafox EVO 2.8 Pure page 169 Datum: 18.04.2024 Version: 04.03.21...
  • Page 177: Description Of The Field Function

    After a valid or only after an invalid measurement, a query can be activated to be able to repeat the measurement. This gives the user the possibility to perform measurements again by one or more repetitions, e.g. if there were still clothes in the measuring range. Handbuch Datafox EVO 2.8 Pure page 170 Datum: 18.04.2024 Version: 04.03.21...
  • Page 178: Operation On The Unit

    5.14.2.2. Operation on the unit In this case the wrist is from the sensor. sensor. In this case the wrist is close to the sensor. sensor away. Handbuch Datafox EVO 2.8 Pure page 171 Datum: 18.04.2024 Version: 04.03.21...
  • Page 179 If the maximum set value is reached, this message appears. Handbuch Datafox EVO 2.8 Pure page 172 Datum: 18.04.2024 Version: 04.03.21...
  • Page 180: Description Of The Field Function In The Display Designer

    Example of the display layout of an EVO 3.5 Pure during measurement. Handbuch Datafox EVO 2.8 Pure page 173 Datum: 18.04.2024 Version: 04.03.21...
  • Page 181 (in the left-hand area) and for the thermometer (in the right-hand area). The combination of arrow symbols for the three possible distance states. • Guide the wrist towards the sensor. Handbuch Datafox EVO 2.8 Pure page 174 Datum: 18.04.2024 Version: 04.03.21...
  • Page 182 Please note the maximum image sizes when specifying. Images that are too large will be scaled down to the maximum possible size. Smaller images will be aligned in the centre. Handbuch Datafox EVO 2.8 Pure page 175 Datum: 18.04.2024 Version: 04.03.21...
  • Page 183: Technical Specifications Evo 2.8 /3.5 /5.0 Pure

    Protection IP 54 Software Configuration program Setup program (Datafox-Studio) to configure without programming effort Communication tools HTTP(S), library (DLL, so) or C++ source code for integration in the application Module extensions For the extension to a variety of functions such as communication, inputs/outputs, sensors are 5 expansion slots for modules...
  • Page 184: Communication Modules

    RS485 Width 20mm RS485 connection for the access reader, relay modules, ... power sup- ply from 1 external reader when using Datafox power supplies with Access Control-IO Width 20mm 1 relay changeover, 42 V AC, DC 60 V, 2 A, max. 60 W; 1 digital input for monitoring door, ...
  • Page 185 Integration of a Burglar Detection System (BDS) 117 Intended Use and Environmental Protection 5 introduction 2 Kommunikation 51 Umschalten 51 Lautstärke 19 Mobilfunk Verbindung Status 69 power supply 41 POE 41 Handbuch Datafox EVO 2.8 Pure page 178 Datum: 18.04.2024 Version: 04.03.21...

This manual is also suitable for:

Evo 3.5 universal

Table of Contents