Page 1
IP RESET MICRO SD CARD ETHERNET PORT CHASSIS PLATE AND LED INDICATORS EARTH CONNECTION POWER AND 16 DIGITAL INPUTS PANEL MOUNT 8 DIGITAL OUTPUTS (NPN) STEPPER AXES (0-2) D-TYPE CONNECTOR STEPPER / ENCODER AXIS (3) D-TYPE CONNECTOR 15 WAY D-TYPE AUXILIARY CONNECTOR QUICK START GUIDE MC404-Z P855...
SAFETY WARNING SAFETY WARNING During the installation or use of control systems, users of Trio products must ensure that there is no possibility of injury to any During the installation or use of control systems, users of Trio products must ensure that there is no possibility of injury to any person or damage to machinery.
Page 3
POWER / DIGITAL OUTPUT CONNECTOR (NPN) POWER / DIGITAL OUTPUT CONNECTOR (NPN) DIGITAL INPUT CONNECTOR (NPN / PNP) DIGITAL INPUT CONNECTOR (NPN / PNP) This is a 12 way 3.5mm pitch connector. Pins 1 to 4 are used This is a 12 way 3.5mm pitch connector. Pins 1 to 4 are used to provide the 24 Volt power to the MC404-Z.
Page 4
STEPPER AXIS CONNECTOR (0-2) 9 way D-type Axis connectors Pin Number Axis 0 to 2 (Stepper) Step+ Step- Dir+ Dir- 0V Step Enable+ Enable- STEPPER OUT / ENCODER IN AXIS CONNECTOR (3) RS422 Line Driver 9 way D-type Axis connectors Pin Number Axis 3 (Stepper OR Encoder) Encoder In...
AUXILIARY CONNECTOR 15 way Auxiliary D-Sub Connector Pin Number Function Note RS232 Transmit Serial Port #1 RS485 Data In A Rx+ Serial Port #2 RS485 Data Out Y Tx+ Serial Port #2 AIN (Analog In) 0V to 10V max, 12 bits WDOG A Solid State Relay Output CAN HIGH...
GROUNDING AND SHIELDING Good quality screened cables should be used for the auxiliary port. The serial ports and CANbus port are not galvanically isolated, therefore the 0V return MUST be connected to all peripheral devices. In addition, bond together the 0V (24V return) terminals of all system components so as to minimise current flowing in the serial cables.
LED STATUS INDICATORS Display at start-up Display with WDOG on Display Motion Error green - ON red - OFF green - ON red - FLASHING green - ON red - ON CHASSIS MOUNTING DIMENSIONS (LOOKING FROM REAR) M4 screws should be used in 3 places to mount the MC404-Z to an unpainted earthed metal panel. Best EMC performance is obtained when all 3 screws are attached to the unpainted metal back panel.