  • Page 2 Spannungsversorgung. Indication 12 V operating voltage for channel Sum socket for interconnecting two SI 1019 A modules 0 - 3. Ooes not light up at failure in for building up a system with more than 9 channels. the voltage supply.
  • Page 3 NF-Anschluß........... Anschluß der Leistungsstrahler SZI1 019 A ....... .
  • Page 4: Mechanik

    Der Anschluß des Strahlers erfolgt über 50 Q- Koaxialkabel. Dazu bietet Sennheiser folgende Kabel an: AV 20 (20 m), GZL 1019 A 10 (10m), GZL 1019 A 5 (5 m) und GZL 1019 A 1 (1 m). Die Signalzuführung vom ersten Strahler zum zweiten, vom zweiten zum dritten usw.
  • Page 5: Inbetriebnahme

    Rückseite je eine mit L gekennzeichnete Buchse@, die Sie miteinander verbinden müssen. Strahler können Sie sowohl an den ersten, als auch an den zweiten Sender anschließen, da das -J3gangssignaldurch die Verkoppelung beider Geräte identisch ist.
  • Page 6 Prinzipschaltbilddes 5teuersenders 51 1019 A Fehlercheckliste (Die Kanäle 2, 6, 7 und 8 sind hier abgeschaltet) Fehler Ursache Abhilfe Kanalmoduloder LED @ bzw. CD a) Kanalmodul einzeln abschalten, bis LED wieder leuchtet nicht Stromversorgungs- leuchtet. Das Modul, bei dem LED wieder auf-...
  • Page 7: Description Of Components

    Chassis SIC 1019 A 20 on with the housing SIG 1019 or the carrying case EMK 1036 (fig. 4 + 5). In any case the transmit- The 19"-chassis ofters enough space tor one power supply module SIS 1019 A 20 and 9 channel ter should get enough ventilation.
  • Page 8: Operation

    CD. cables: AV 20 (20 m), GZL 1019 A 10 (10m). GZL 1019 A 5 (5 m) and GZL 1019 A 1 (1 m). The si- gnal is looped Irom the lirst radiator to the second, lram the second to the third etc. (see user's guide SZI1 019 A).
  • Page 9: Power Supply Module

    0.8 AT for 220 V mains supply 1.6 ATfor 11O V mains supply The radiators can be connected to elther the first or the second transmitter, as the output signal of both transmitters is identical. Number of channels .
  • Page 10: Block Diagram

    SZI1 019 A. Le chassis peut etre dans un rack de 19" ou etre utilise comme appareil de table avec le boltier SIG 1019 ou la valise EMK 1036. Les places de module non utilisees peuvent etre obturees par les plaques vierges SIB 1019.
  • Page 11: Connexion Bf

    1/ 11 11 1\ i\ i\ '\\ \\ '\~ Mecanique - Le chassis esl prevu pour eIre place dans un rack de 19". Le cablage BF s'effeclue par devanl, =f4. mais peul eIre deplace vers I'arriere si necessaire. Comme les connexions...
  • Page 12: Mise En Service

    Cet operation necessite un deuxieme chassis SIC 1019 A 20, un module d'alimentation SIS 1019 A 20, trois modules de canal SIK 1019 A et six plaques vierges SIB 1019. Pour que les deux chassis soient couples electriquement, les bornes @ marquees par le signe .E et se trouvant sur la face arriere devront etre reliees.
  • Page 13 Liste des erreurs Schema de principe de I'emetleur pilote SI1 019 A (Ies canaux 2, 6, 7 et8 so nt hors service) Erreurs Cause Correction Module de canal ou LED @ ou (J) a) ArrE\ter chaque module separement jusqu'a ce d'alimentation que la LED brille.
  • Page 14 " " '" ~N3~, 08-0 NO,B131 0-8BS/08~SO X3l31 8Z9vZ6...