Gas conversion instructions
3. Close the door and wait for the thermostat to operate
and turn the burner down to maintain 120°C. The
burner should stay alight. If the burner does not stay
alight, adjust the turndown for the burner at the gas valve
slightly counterclockwise. Refer to Gas Hob Conversion
instructions on how to locate the adjustment screw.
Table for injector sizes
The following table shows the injector sizes for each burner.
Burner
Intense heat wok burner
High heat burner
Medium heat burner
Low heat burner
Grill
Oven
16 Chef 540 Upright Cooker
Natural gas
(Nominal test point pressure:
1.00kPa)
1.75
1.60
1.35
1.00
1.50
1.60
Injector Size (mm)
Propane – For Australia only
(Nominal test point pressure:
2.75kPa)
1.00
0.95
0.82
0.62
0.82
0.95
ULPG - For NZ only
(Nominal test point pressure:
2.75kPa)
1.00
0.90
0.70
0.55
0.82
0.82