CYP AU-A300 Operation Manual

Integrated 2 channel zone amplifier
Hide thumbs Also See for AU-A300:

Advertisement

Quick Links

AU-A300
Integrated 2 Channel Zone Amplifier
OPERATION MANUAL

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AU-A300 and is the answer not in the manual?

Questions and answers

Summary of Contents for CYP AU-A300

  • Page 1 AU-A300 Integrated 2 Channel Zone Amplifier OPERATION MANUAL...
  • Page 3 DISCLAIMERS The information in this manual has been carefully checked and is believed to be accurate. CYP (UK) Ltd assumes no responsibility for any infringements of patents or other rights of third parties which may result from its use. CYP (UK) Ltd assumes no responsibility for any inaccuracies that may be contained in this document.
  • Page 4 SAFETY PRECAUTIONS Please read all instructions before attempting to unpack, install or operate this equipment and before connecting the power supply. Please keep the following in mind as you unpack and install this equipment: • Always follow basic safety precautions to reduce the risk of fire, electrical shock and injury to persons.
  • Page 5: Table Of Contents

    CONTENTS 1. Introduction ...........6 2. Applications ...........6 3. Package Contents ........6 4. System Requirements ......6 5. Features ..........7 6. Operation Controls and Functions ..8 6.1 Front Panel ........... 8 6.2 Rear Panel ............. 9 6.3 Remote Control ........10 6.4 OLED Menu ..........11 6.5 RS-232 Protocols ........12 6.6 RS-232 and Telnet Commands ....13 6.7 Telnet Control ..........15...
  • Page 6: Introduction

    1. INTRODUCTION The Integrated Zone Amplifier accepts analogue and digital stereo audio signals via RCA, 3.5mm mini-jack, optical and coaxial digital, and HDMI with an additional microphone input. As well as speaker outputs, it boasts line level output, optical and digital outputs, and HDMI outputs for wider systems integration.
  • Page 7: Features

    5. FEATURES  30 watts per channel Digital Stereo Amplifier  Supports Digital to Analogue audio Conversion (DAC) and Analogue to Digital audio Conversion (ADC)  HDMI audio embedding and de-embedding  Supports input audio sampling rates up to 96 kHz and output at 48 kHz  Supports HDMI audio sampling rates loop-through and video bypass output...
  • Page 8: Operation Controls And Functions

    6. OPERATION CONTROLS AND FUNCTIONS 6.1 Front Panel PUSH UPDATE CONTROL EXIT POWER Coaxial In -20.0 dB 44.1K -> 44.1K Integrated Zone Amplifier MIC: Connect to a microphone or a mono balanced source. UPDATE: Manufacturer use only. OLED: Display current source selection and volume setting. IR WINDOW: Accepts the IR signal from the supplied remote control.
  • Page 9: Rear Panel

    6.2 Rear Panel CONTROL IR IN LINE IN RS-232 OPT. COAX. SPEAKER HDMI OUT HDMI IN 1 HDMI IN 2 OPT. COAX. DC 24V CONTROL: Connect to an active network with RJ45 cable for Telnet/ WebGUI control. HDMI OUT: Connect to HDTV/monitor for both audio and video display.
  • Page 10: Remote Control

    6.3 Remote Control MUTE POWER: Press this button to turn the unit POWER On or to set it into standby mode. MENU MUTE: Press this button to mute the audio output. VOL. EXIT VOL. UP ( ▲ ) or DOWN ( ▼ ): Press these buttons to turn the output volume up or HDMI 1 HDMI 2...
  • Page 11: Oled Menu

    6.4 OLED Menu MAIN MENU SUB MENU ADJUSTMENTS Function Select Audio In HDMI Set Display Set MIC Set Line Out Set IP Config Reset to Default Audio Select HDMI1 HDMI2 Optical In Coaxial In Line In RCA (L/R) In HDMI Setting Video HDMI 1 HDMI 2...
  • Page 12: Rs-232 Protocols

    6.5 RS-232 Protocols AMPLIFIER REMOTE CONTROL ASSIGNMENT ASSIGNMENT ► ◄ Baud Rate: 115200bps Data bit: 8 bits Parity: None Flow Control: None Stop Bit: 1...
  • Page 13: Rs-232 And Telnet Commands

    6.6 RS-232 and Telnet Commands COMMAND DESCRIPTION HELP Display list of commands. Alias for HELP. Alias for HELP. Power control. PWR S/0/1 S=Status, 0=Off, 1=On Source in selection. SOURCE S/0~5 S=Status, 0=HDMI 1, 1=HDMI 2, 2=Opt, 3=Coax, 4=Line In, 5=RCA In Output volume setting of 0~80db.
  • Page 14 COMMAND DESCRIPTION SGATEWAY Set the Gateway address. Set the HTTP communication port (1~62235) SHTTPPORT [Default values=80]. Set the Telnet communication port (1~62235) STELNETPPORT [Default values=23]. Note: RS-232 commands will be not executed unless followed by a carriage return. Commands are case-sensitive.
  • Page 15: Telnet Control

    6.7 Telnet Control Before using the Telnet control, please ensure that both the Integrated Zone Amplifier (via the 'CONTROL' port) and the PC/Laptop are connected to the same active network. To access the Telnet control in Windows 7, click on the 'Start' menu and type "cmd"...
  • Page 16 This will bring us into the unit which we wish to control. Type "H" to list the available commands. Type “IPCONFIG” to show all IP configurations. To reset the IP, type “RESETIP”. Note: All the commands will be not executed unless followed by a carriage return.
  • Page 17: Webgui Control

    6.8 WebGUI Control On a PC/Laptop that is connected to the same active network as the Integrated Zone Amplifier, open a web browser and type unit's IP address into the web address entry bar. The browser will display the unit's control page.
  • Page 18: Connection Diagram

    7. CONNECTION DIAGRAM Smartphone or Tablet Set-top Box CD Player Digital Optical Analogue and Coaxial Stereo PC or RS-232 Inputs Input Control System Analogue Stereo Input 2nd Integrated RS-232 Zone Amplifier CONTROL IR IN LINE IN RS-232 OPT. COAX. SPEAKER HDMI OUT HDMI IN 1 HDMI IN 2...
  • Page 19: Specifications

    8. SPECIFICATIONS 8.1 Technical Specifications Input Ports 2×HDMI, 1×Optical, 1×Coaxial, 1×3.5mm Mini-jack, 2×RCA (Analogue Stereo), 1×Microphone, 1×D-sub 9-pin (RS-232), 1×RJ-45 (Control), 1×IR Extender Output Ports 1×HDMI, 1×Optical, 1×Coaxial, 2×RCA (Analogue Stereo), 1×Speaker Digital Audio Input/ LPCM 2CH Output Stereo Input/Output 2 Vrms ±...
  • Page 20: Audio Specifications

    8.2 Audio Specifications Input Output Freq Output Level T.H.D+N Level/Freq Interface Response HDMI HDMI 1/2 OPTICAL 0 dB±1 dB <0.01 % ±1 dBFS >80 dB OPTICAL COAX COAX 0 dBFS/1 kHz 2.0Vrms ±10 % <0.1 % ±1 dBFS >70 dB HDMI Analogue L/R OPTICAL...
  • Page 21: Acronyms

    9. ACRONYMS ACRONYM COMPLETE TERM CAT5e Category 5 Cable CAT6 Category 6 Cable COAX Coaxial HDMI High-Definition Multimedia Interface OLED Organic Light-Emitting Diode Optical...
  • Page 24 CYP (UK) Ltd., Unit 7, Shepperton Business Park, Govett Avenue, Shepperton, Middlesex, TW17 8BA Tel: +44 (0) 20 3137 9180 | Fax: +44 (0) 20 3137 6279 Email: sales@cypeurope.com www.cypeurope.com v1.05...

Table of Contents