5.1
E-CELL STACK™ MAXIMUM POWER REQUIREMENTS
INPUT
VOLTAGE
100-600V
5.2

OPERATING CURRENT

In order for the E-Cell Stack™ to produce high quality water, the current flow must be
sufficient for the ionic load in the feed water. In general, more current is required as the
ionic load increases. More current is also required for silica removal.
6.

MECHANICAL AND HYDRAULIC

Do not adjust the bolts on the E-Cell Stack
permanent damage to the E-Cell Stack
Care must be taken to protect against water hammer. Feed Water pressure should never
exceed 100 psi (6.8 bar)
rev.1.1
INPUT
MAX
CURRENT
POWER
0.5-4.5A
2.7 kW
and voids the warranty.