56-MELR Retrofit Kit
PED Series Exit Devices
Installation Instructions
9
Dogging Slope
Remove screw from dogging slope assembly. Replace it
with the longer screw from the
retrofit kit. The longer screw will hold the plug in place.
Discard dogging cam, bushing, & spring.
11
Reattach the dogging slope on the assembly with the
four screws from step eight.
Note: The dogging slope is reattached to the new carrier
assembly received with the ELR kit.
For installation assistance contact Corbin Russwin
1-800-543-3658 • techsupport.corbinrusswin@assaabloy.com
Copyright © 2023, ASSA ABLOY Access and Egress Hardware Group, Inc. All rights reserved.
Reproduction in whole or in part without the express written permission of ASSA ABLOY Access
and Egress Hardware Group, Inc. is prohibited.
Screw
Plug
Cylinder
Dogging
Spring
Dogging Cam
10
Drop the plug into the dogging slope. Use the longer
screw to secure it in place.
12
Attach the wire harness to the controller before it's locked
into the dogging slope.
Take the controller and plug it into the back of the dogging
slope assembly. Align the plastic teeth and slide it in so the
unit locks into the dogging slope.
3
FM805 12/23
Need help?
Do you have a question about the Corbin Russwin PED5000 Series and is the answer not in the manual?
Questions and answers