Download Print this page

Assa Abloy Corbin Russwin DC5200 Installation Instructions Manual page 8

Cam action door closer

Advertisement

Setup for Inclusive Restroom/Telephone Booth Function
1. Open the door to the desired "propped" position.
2. With the arm parallel to the door, insert the spline
shaft into the closer body.
3. Secure the arm to the slider stud using the
5mm hex wrench. Rotate counter-clockwise
until tightened (see figure 1 on page 7).
4. Slide the spline vertically in or out of the closer
up to 1/2" until arm is parallel to the track. Install
plastic bushing on opposite side of spline shaft with
the black screw provided.
5. Slowly open the "C" and "L" valves on the closer body.
6. Adjust closer power. See "Power Adjustment Chart" on page 2,
closer valves and hold open device (for DC5200A1 models) on page 7.
WARNING
This product can expose you to lead which is known to the state
of California to cause cancer and birth defects or other reproduc-
tive harm. For more information go to www.P65warnings.ca.gov.
WARNING
Attention Installer: Improper installation may result
in damage to the product and void the factory
warranty.
FM806 Rev 3 03/24