Produal DPT-Flow-MOD User Manual

Modbus air flow transmitter

Advertisement

Quick Links

DPT-Flow-MOD Modbus air flow transmitter
User Guide

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DPT-Flow-MOD and is the answer not in the manual?

Questions and answers

Summary of Contents for Produal DPT-Flow-MOD

  • Page 1 DPT-Flow-MOD Modbus air flow transmitter User Guide...
  • Page 2: Table Of Contents

    4.3.1 Coils......................10 4.3.2 Input registers....................10 4.3.3 Holding registers................... 11 5 Disposal.................. 12 Produal Oy | Keltakalliontie 18, FI 48770 Kotka, Finland | tel. +358 10 219 9100 | info@produal.com Information is subject to change without prior notice. EN - 102.011.033ug...
  • Page 3: Safety Precautions

    Read this user guide carefully before commissioning, using or servicing this device. To avoid any kind of damage to people or property, follow the instructions carefully. Produal is not liable for any hazards or damages to people or property which are caused by ignoring the using or installation instructions.
  • Page 4: Commissioning

    4.3 mm. Important: Don't use excessive force when tightening the mounting screws. Produal Oy | Keltakalliontie 18, FI 48770 Kotka, Finland | tel. +358 10 219 9100 | info@produal.com Information is subject to change without prior notice. EN - 102.011.033ug...
  • Page 5: Wiring

    CAUTION: Ensure that all covers are closed before connecting supply voltage to the product. Don't remove the covers when the supply voltage is connected. Produal Oy | Keltakalliontie 18, FI 48770 Kotka, Finland | tel. +358 10 219 9100 | info@produal.com Information is subject to change without prior notice.
  • Page 6: Configuring Settings Via Device Menu

    The following units are available: Produal Oy | Keltakalliontie 18, FI 48770 Kotka, Finland | tel. +358 10 219 9100 | info@produal.com Information is subject to change without prior notice.
  • Page 7 • Pa • kPa • NONE • psi • mbar • "WC Produal Oy | Keltakalliontie 18, FI 48770 Kotka, Finland | tel. +358 10 219 9100 | info@produal.com Information is subject to change without prior notice. EN - 102.011.033ug...
  • Page 8 Modbus parity is selected via Parity bit menu. The bus parity can be none, odd or even. Produal Oy | Keltakalliontie 18, FI 48770 Kotka, Finland | tel. +358 10 219 9100 | info@produal.com Information is subject to change without prior notice.
  • Page 9: Maintenance

    The zeroing is complete when the indicator light turns off. 3. Connect the pressure measurement hoses. Produal Oy | Keltakalliontie 18, FI 48770 Kotka, Finland | tel. +358 10 219 9100 | info@produal.com Information is subject to change without prior notice.
  • Page 10: Modbus

    Flow value (l/s) 0...3000 0...3000 l/s 30007 Velocity value (m/s) 0...1000 0...1000 m/s Produal Oy | Keltakalliontie 18, FI 48770 Kotka, Finland | tel. +358 10 219 9100 | info@produal.com Information is subject to change without prior notice. EN - 102.011.033ug...
  • Page 11: Holding Registers

    0 - 1 - 2 … - 20 0 = 0.4 s, 1...20 s Produal Oy | Keltakalliontie 18, FI 48770 Kotka, Finland | tel. +358 10 219 9100 | info@produal.com Information is subject to change without prior notice. EN - 102.011.033ug...
  • Page 12: Disposal

    Contact your local Produal distributor for further information on environmental aspects and recycling instructions for professional recyclers. Produal Oy | Keltakalliontie 18, FI 48770 Kotka, Finland | tel. +358 10 219 9100 | info@produal.com Information is subject to change without prior notice.

Table of Contents