Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1

Operation

Base Operation
Remote controller
1. Unit start
Press ON/OFF on the remote controller,
unit starts.
2.Select operation mode
Press MODE button: For each press, the
mode changes as follows:
AUTO mode --->Cooling mode --->DRY
mode --->FAN mode--->Heating mode
3.Select temp. setting
Press
/
button
Every time the button is pressed, temp. setting increases
1°C, if kept depressed, it will increase rapidly
Every time the button is pressed, temp. setting decreases
1°C, if kept depressed, it will decrease rapidly
Select a desired temperature.
4.Fan speed selection
Press FAN button. For each press, fan speed changes as follows:
Remote controller:
LO
MED
Air conditioner is running under displayed fan speed.
When FAN is set to AUTO, the air conditioner automatically adjusts
the fan speed according to room temperature.
Remote
Mode
controller
AUTO
COOL
DRY
HEAT
FAN
2
3
4
3
Display
circulated
HI
AUTO
Note
Under the mode of auto operation, air
conditioner will automatically select Cool
or Heat operation according to room
temperature. When FAN is set to AUTO
the air conditioner automatically adjusts
the fan speed according to room tem-
perature.
Cooling only unit do not have displays
and functions related with heating
In DRY mode, when room temperature
becomes lower than temp. setting+2
unit will run intermittently at LOW speed
regardless of FAN setting.
In HEAT mode, warm air will blow out af-
ter a short period of the time due to cold
- draft prevention function. When FAN is
set to AUTO, the air conditioner automat-
ically adjusts the fan speed according to
room temperature.
In FAN operation mode, the unit will
not operate in COOL or HEAT mode
but only in FAN mode, AUTO is not
available in FAN mode. And temp.
setting is disabled. In FAN mode,
sleep operation is not available.
Emergency operation and test operation
Emergency Operation:
1
●Use this operation only when the remote controller is defective or
lost, and with function of emergency running, air conditioner can run
automatically for a while.
●When the emergency operation switch is pressed, the "Pi" sound is
heard once, which means the start of this operation.
●When power switch is turning on for the first time and emergency
operation starts, the unit will run automatically in the following modes:
Room
Designated
temperature
temperature
Above 24 ºC
24 ºC
Below 24 ºC
24 ºC
●It is impossible to change the settings of temp. and fan speed. It is
also not possible to operate in TIMER or DRY mode.
Test operation:
Test operation switch is the same as emergency switch.
●Use this switch in the test operation when the room temperature is
below 16 °C , do not use it in the normal operation.
●Continue to press the test operation switch for
more than 5 seconds. After you hear the "Pi" sound
twice,release your finger from the switch: the cooling
operation starts with the air flow speed "Hi".
Air Flow Direction Adjustment
1. Up and down air flow adjustment
Vertical flap
(Initial state)
2.Left and right air flow adjustment
For each press of SWING button, remote controller displays as
follows:
Remote controller:
Note: In some model: The remote has the button
doesn't have the left and right air flow auto adjustment function,
this condition change the direction of vertical blades manually.This
function is available for the following models:
AS25PBPHRA-PRE
AS25RBAHRA-PL
AS35PBPHRA-PRE
AS35RBAHRA-PL
AS50PDPHRA-PRE
AS50RCBHRA-PL
AS71PEPHRA-PRE
AS68RDAHRA-PL
°C
,
AS25PCHHRA-NR
AS50RDAHRA-PL
AS35PCHHRA-NR
AS50PDHHRA-NR
Cautions:
When adjusting the flap by hand,turn off the unit.
When humidity is high,condensate water might occur at air outlet
if all vertical louvers are adjusted to left or right.
It is advisable not to keep horizontal flap at downward position for
a long time in COOL or DRY mode ,otherwise, condensate water
might occur.
When system is restarted by the remote controller it will
automatically memorise the previous set swing position.
Timer
Fan
Operation
mode
speed
mode
No
AUTO
COOL
No
AUTO
HEAT
COOL/DRY/AUTO/FAN
HEAT
, but the AC
AS25PBPHRA-BH
AS25RBAHRA-5
AS35PBPHRA-BH
AS35RBAHRA-5
AS50PDPHRA-BH
AS50RDAHRA-5
AS25PBPHRA-S
AS68RDAHRA-5
AS35PBPHRA-S
AS50PDPHRA-S
Pi
EN
Pi Pi
4

Advertisement

Table of Contents
loading

Table of Contents