Haier AS25PBAHRA Service Manual

Haier AS25PBAHRA Service Manual

Wall mounted type dc inverter
Hide thumbs Also See for AS25PBAHRA:

Advertisement

SE RVICE MANUAL
Wall Mounted Type
DC Inverter
Model No.
AS25PBAHRA
WARNING
This servic e informatio n is designed for experience d repai r technician s only and is not designe d for use by the genera l public.
It does not contai n warning s or caution s to advise non-technic al individu als of potentia l dangers in attemptin g to servic e a product.
Product s powered by electricit y shoul d be service d or repaire d only by experience d professiona l technicia ns. Any attemp t to service or
Repai r the produc t or product s deal t with in this servic e infor mation by anyone else could result in seriou s injury or death
202 0 (Qing dao Haie r Air Condi tione r Genera l corp . , Ltd)
All right s reser ved. Unauthoriz ed copying and distributio n is a violati on of law
Haier Group
Version V1
Date 2020-10-28

Advertisement

Table of Contents
loading

Summary of Contents for Haier AS25PBAHRA

  • Page 1 Wall Mounted Type DC Inverter Model No. AS25PBAHRA WARNING This servic e informatio n is designed for experience d repai r technician s only and is not designe d for use by the genera l public. It does not contai n warning s or caution s to advise non-technic al individu als of potentia l dangers in attemptin g to servic e a product.
  • Page 2: Table Of Contents

    Table of contents Contents 1. Introduction .................... 1 2. Features ....................7 3. Specifications ..................8 4. Sensors list.................... 9 5. Piping diagrams ..................10 6. Printed circuit board connector wiring diagram........11 7. Functions and control ................8. Dimensional drawings ................9.
  • Page 3: Introduction

    Introduction 1. Introduction 1.1 Model name explanation Apply toT1; 220~240V50HZ/1ph DC inverter Indoor units Version number 35 capicity Platform of indoor units: P (P platform) Nominal cooling capacity (9000BTU/h) Type of indoor unit: S (wall-mounted) Indoor unit Domestic air conditioner...
  • Page 4 Introduction 1.2 Safety Cautions Be sure to read the following safety cautions before conducting repair work. The caution items are classified into “Warning” and “Caution”. The “Warning” items are especially important since they can lead to death or serious injury if they are not followed closely. The “Caution” items can also lead to serious accidents under some conditions if they are not followed.
  • Page 5 Introduction Warning Do not repair the electrical components with wet hands . Working on the equipment with wet hands can cause an electrical shock Do not clean the air conditioner by splashing water. Washing the unit with water can cause an electrical shock.
  • Page 6 Introduction Warning Be sure to use an exclusive power circuit for the equipment, and follow the technical standards related to the electrical equipment, the internal wiring regulations and the instruction manual for installation when conducting electrical work. Insufficient power circuit capacity and improper electrical work can cause an electrical shock or fire. Be sure to use the specified cable to connect between the indoor and outdoor units.
  • Page 7 Introduction Caution Installation of a leakage breaker is necessary in some cases depending on the conditions of the installation site, to prevent electrical shocks. Do not install the equipment in a place where there is a possibility of combustible gas leaks. If a combustible gas leaks and remains around the unit, it can cause a fire.
  • Page 8 Introduction Caution Check to see if the parts and wires are mounted and connected properly, and if the connections at the soldered or crimped terminals are secure. Improper installation and connections can cause excessive heat generation, fire or an electrical shock. If the installation platform or frame has corroded, replace it.
  • Page 9: Features

    UVC Sterilization:Emits UV light to sterilize the air passing through with efficiency up to 92%.The sterilization rate of single UV module : 99.9% Wi-Fi Control:Download the Haier hOn App to an Apple or Android smart device, and link the equipment to the smart device for system control from whenever and wherever you want.
  • Page 10: Specifications

    Specifications 3.Specifications NOMINAL DISTRIBUTION SYSTEM VOLTAGE NOMINAL CAPACITY and NOMINAL INPUT n i l 2.6(0.8-3.0) 2.8(0.8-3.2) Capacity rated Btu/h 9555(2730-10920) 8870(2730-10238) 0.75 ³ 1.2*10 ³ TECHNICAL SPECIFICATIONS 805 200*292 874*270*363 10.6 White Sound dB(A) 37/32/28 peessure(Hi/Mid/Lo) Sound level Sound power(high) dB(A) Domestic air conditioner...
  • Page 11: Sensors List

    Specifications TECHNICAL SPECIFICATIONS-PARTS cooling heating Air flow rate(high) m³/h 1050/900/750 Speed(Hi/Mid/Lo) 1150/1000/850 Type ML fin- 5HI-HX tube Heat exchanger c t i Up and Removable/Washable/Mildew Proof Air filter Microcomputer Control Temperature control l l o 0010401715B Note: the data are based on the conditions shown in the table below Conversation formulae n i l Kcal/h= KW×860...
  • Page 12: Piping Diagrams

    Piping diagrams 5 Piping diagrams Domestic air conditioner...
  • Page 13: Printed Circuit Board Connector Wiring Diagram

    Printed circuit board connector wiring diagram 6.Printed circuit board connector wiring diagram Connectors PCB(1) (Control PCB) For AS25PBAHRA N_RC UNIT MODEL PCB MODEL AS25PBAHRA 0011800594(23 ) DISPLAY SERIES 325/798 387/1045 DISPLAY MODEL UNIT MODEL 0011801045 AS25PBAHRA Domestic air conditioner...
  • Page 14 Printed circuit board connector wiring diagram PCB(1) generator Fan motor Remote controller Ambient & Pipe Temp. sensor Wired controller Anion module ● Display board Emergency Up-down stepmotor Room card wifi ● Mag switch Human-light Right -left ● sensors stepmotor controller ●...
  • Page 15 Printed circuit board connector wiring diagram Wiring diagrams Domestic air conditioner...
  • Page 16: Functions And Control

    Functions and control 7.Funcitions and control 7.1 Main functions and control specification 7.1.1 Automatic operation When the running mode is turned to automation after starting the system, the system will first determine the running mode according to the current room temperature and then will run according to the determined mode.
  • Page 17 Functions and control 7.1.3 Dehumidifying mode. * temperature control range: 16---30 * temperature difference: Control feature: send the dehumidifying signal to the outdoor system. When Tr>Ts+2 , the compressor will be turned on, the indoor fan will operate at the set speed. When Tr is between the Ts and Ts+2 , the outdoor system will operate at the high dehumidifying frequency for 10 minutes and then at the low dehumidifying mode for six minutes.
  • Page 18 Functions and control malfunctions when dehumidifying. * Timing system on/off function. * Dormant control functio n. 7.1.4 Heating operation mode. * temperature control range: 16---30 * temperature difference: * control feature: the temperature compensation is automatically added and the system will send the heating signals to the outdoor system.
  • Page 19 Functions and control temperature compensation (4 ) will be added. When the status is switched off, the compensation will be erased. 7.1.5 Strength operation The system enters the mode after receiving the ‘strength signal’. Send strength operation signal to the outdoor system. The mode change finishes the strength operation.
  • Page 20 Functions and control 7.1.9 Dormant operation The dormant timing is an eight hours unadaptable one. The timing signs are shown on the V series board. (RC series show the dormant signal, the timing light is lighted on the 6 lights board). 2.1 Under the cooling/ dehumidifying operation, after the setting of the dormant operation, the set temperature will be raised for 1 centigrade after 1 hour’s operation and will be raised for 1 centigrade 1 hour later.
  • Page 21 Functions and control 7.1.11 Low load protection control In order to prevent the frosting of the indoor heat interaction device, the outdoor system will be stopped if the indoor heat interaction temperature is below 1 centigrade for 5 minutes, but the fan will continue to operate.
  • Page 22 Functions and control temperature goes beyond this range, the abnormality can be confirmed. If the temperature goes back into the range, the system will automatically resume. 3 .indoor malfunction: Out door malfunction: When the indoor system receives the outdoor malfunction codes, it will store the code into E2 for the malfunction list resume.
  • Page 23 Functions and control 7.2 Value of thermistor Room sensor and Pipe Sensor R25 =10K B25 /50 =3700K 2% Temp.(( )) Max.(K ) Normal(K ) Min.(K ) Tolerance( ) 165.2170 147.9497 132.3678 -1.94 1.75 155.5754 139.5600 125.0806 -1.93 1.74 146.5609 131.7022 118.2434 -1.91 1.73...
  • Page 24 Functions and control 23.0284 21.8398 20.6939 -1.18 1.14 21.9714 20.8659 19.7982 -1.15 1.12 20.9688 19.9409 18.9463 -1.13 1.09 20.0176 19.0621 18.1358 -1.11 1.07 19.1149 18.2270 17.3646 -1.08 1.05 18.2580 17.4331 16.6305 -1.06 1.03 17.4442 16.6782 15.9315 -1.03 1.01 16.6711 15.9601 15.2657 -1.01 0.99...
  • Page 25 Functions and control 4.0588 3.8287 3.6084 -1.70 1.62 3.9206 3.6943 3.4780 -1.74 1.66 3.7878 3.5654 3.3531 -1.78 1.70 3.6601 3.4416 3.2332 -1.82 1.74 3.5374 3.3227 3.1183 -1.87 1.78 3.4195 3.2085 3.0079 -1.91 1.82 3.3060 3.0989 2.9021 -1.95 1.85 3.1969 2.9935 2.8005 -2.00 1.89...
  • Page 26 Functions and control 1.0607 0.9599 0.8679 -3.74 3.42 1.0314 0.9326 0.8424 -3.80 3.46 1.0030 0.9061 0.8179 -3.85 3.51 0.9756 0.8806 0.7941 -3.90 3.55 0.9490 0.8558 0.7711 -3.96 3.60 0.9232 0.8319 0.7489 -4.01 3.64 0.8983 0.8088 0.7275 -4.07 3.69 0.8741 0.7863 0.7067 -4.12 3.74...
  • Page 27: Center Of Gravity

    Service diagnosis 8.Dimensional unit:mm 501.6 9.Center of gravity unit:mm Domestic air conditioner...
  • Page 28: Service Diagnosis

    Service diagnosis 10. Service Diagnosis 10.1 Caution for Diagnosis The operation lamp flashes when any of the following errors is detected. 1. When a protection device of the indoor or outdoor unit is activated or when the thermistor malfunctions, disabling equipment operation. 2.
  • Page 29 Service diagnosis 10.3 Error Codes and Description indoor display Code indication Indoor displaying panel code indication Outdoor Referenc Only For 498 and fault description (LED1 e Page 498A display flash Other display (Red/Green Time Run times) □On★Flash■Off) Indoor Communication fault between ■...
  • Page 30 Service diagnosis 10.3.1 Thermistor or Related Abnormality Indoor Display E1: Room temperature sensor failure E2: Heat-exchange sensor failure Outdoor display LED1 flash 10 times Defrost temperature sensor failure LED1 flash 11 times Suction temperature sensor failure LED1 flash 12 times Ambient temperature sensor failure LED1 flash 13 times Discharge temperature sensor failure Method of The temperatures detected by the thermistors are used to determine thermistor errors...
  • Page 31 Service diagnosis 10.3.2 EEPROM abnormal Indoor Display E4: Indoor EEPROM error Indoor display F12: Outdoor EEPROM error; Outdoor LED1 flash 1 times Method of The Data detected by the EEPROM are used to determine MCU Malfunction Detection Malfunction When the data of EEPROM is error or the EEPROM is damaged Decision Conditions Supposed...
  • Page 32 Service diagnosis 10.3.3 Indoor DC fan motor malfunction Indoor Display Method of The rotation speed detected by the Hall IC during fan motor operation is used to determine Malfunction abnormal fan motor operation Detection Malfunction when the detected rotation feedback signal don’t received in 2 minutes Decision Conditions Supposed...
  • Page 33 Service diagnosis 10.3.4 Outdoor DC fan motor fault Outdoor display LED1 flash 9 times Method of DC fan motor is detected by checking the fan running condition and so on Malfunction Detection Malfunction when the data of EEPROM is error or the EEPROM is damaged Decision Conditions Supposed...
  • Page 34 Service diagnosis Check whether Terminal on the outdoor mainboard is well inserted. it is normal Reinsert the terminals Electrify the machine again and turn it on in The motor and the Cool state with the remote controller. outdoor pcb are check whether the motor could run.
  • Page 35 Service diagnosis 10.3.5 IPM protection Outdoor display: / F1 LED1 flash 2 times Method of IPM protection is detected by checking the compressor running condition and so on Malfunction Detection Malfunction The system leads to IPM protection due to over current Decision The compressor faulty leads to IPM protection Conditions...
  • Page 36 Service diagnosis 10.3.6 Over-current of the compressor Outdoor Display: F2 LED1 flash 3 or 24 or 25 times Method of The current of the compressor is too high Malfunction Detection Malfunction when the IPM Module is damaged Decision or the compressor is damaged. Conditions power supply voltage is too low or too high Supposed...
  • Page 37 Service diagnosis 10.3.7 The communication fault between IPM and outdoor PCB Outdoor display: LED1 flash 4 times Method of Communication is detected by checking the IPM module and the outdoor PCB Malfunction Detection Malfunction The outdoor PCB broken leads to communication fault Decision The IPM module broken leads to communication fault Conditions...
  • Page 38 Service diagnosis 10.3.8 Power Supply Over or under voltage fault Outdoor display: LED1 flash 6 times The power supply is over voltage Method of An abnormal voltage rise or fall is detected by checking the specified voltage detection circuit. Malfunction Detection Malfunction An voltage signal is fed from the voltage detection circuit to the microcomputer...
  • Page 39 Service diagnosis 10.3.9 Overheat Protection For Discharge Temperature Outdoor display: F4 LED1 flash 8 times Method of The Discharge temperature control is checked with the temperature being detected Malfunction by the Discharge pipe thermistor Detection Malfunction when the compressor discharge temperature is above 110 Decision Conditions Supposed...
  • Page 40 Service diagnosis 10.3.10 The communication fault between indoor and outdoor Indoor display outdoor display LED1 flash 15 times Method of Communication is detected by checking the indoor PCB and the outdoor PCB. Malfunction Detection Malfunction The outdoor PCB broken leads to communication fault. Decision The indoor PCB broken leads to communication fault.
  • Page 41 Service diagnosis If the voltage is a constant value The indoor mainboard is of 0V DC to 5V DC.Or the voltage damaged; replace it with a between Communication line(red ) and N(white new one. line) is not close to18V DC when only indoor charged. Test the outdoor power is Check the cable supply 230VAC with a...
  • Page 42 Service diagnosis 10.3.11 Loss of synchronism detection Inverter side current detection is abnormal Outdoor Display LED1 flash 18 times LED1 flash 19 times Method of The position of the compressor rotor can not detected normally Malfunction Detection Malfunction when the wiring of compressor is wrong or the connection is poor; Decision or the compressor is damaged Conditions...
  • Page 43 Service diagnosis 10.3.12 High work-intense protection Outdoor display LED1 flash 21 times Method of High work-intense control is activated in the heating mode if the temperature Malfunction being sensed by the heat exchanger thermistor exceeds the limit. Detection Malfunction Activated when the temperature being sensed by the heat exchanger Decision rises above 65 twices in 30 minutes.
  • Page 44: Circuit Diagrams

    Circuit diagrams 11. Circuit Diagrams Domestic air conditioner...
  • Page 45 Circuit diagrams Domestic air conditioner...
  • Page 46 Sincere Forever Haier Group Edited by : Jing yanqin Haier Industrial Park, No.1, Haier Road Wang wanli 266101, Qingdao, China_ Signed by : Yang Wenjun Http //www.haier.com Approved by: Wu Hongjin Domestic air conditioner...
  • Page 47 Repair the product or products dealt with in this service information by anyone else could result in serious injury or death 2015 (Qingdao Haier Air Conditioner General corp. , Ltd) All rights reserved. Unauthorized copying and distribution is a violation of law...
  • Page 48 Removal Procedure Removal of front panel front panel Remove the foam cushion Loosen the screw Domestic Air Conditioner...
  • Page 49 Removal Procedure Lift up the control box cover Loosen the screw Lift up the control box cover Domestic Air Conditioner...
  • Page 50 Removal Procedure Removal of front panel Pull the wires out of the control box and then release the pivots on both sides of the unit to remove the front panel. Remove the air filters Domestic Air Conditioner...
  • Page 51 Removal Procedure Remove the casing three Domestic Air Conditioner...
  • Page 52 Removal Procedure horizontal flap and the stepper motor flap Loosen the screws and remove the stepper motor Domestic Air Conditioner...
  • Page 53 Removal Procedure horizontal louver and control box Every blade go round and round,then move Loosen the screws Domestic Air Conditioner...
  • Page 54 Removal Procedure Loosen the hook and the service Cover Lift up the exchanger and remove it Domestic Air Conditioner...
  • Page 55 Removal Procedure motor cover motor cover Domestic Air Conditioner...
  • Page 56 Removal Procedure Domestic Air Conditioner...

Table of Contents