The appliance must be installed and commissioned by a competent person in accordance with established regulations and local health and safety regulations.
See electrical diagrams at the end of the booklet.
BEFORE BEGINNING ANY WORK ON THE ELECTRICAL INSTALLATION BE SURE THAT THE CIRCUIT BREAKER IS IN THE "OFF" POSITION TO AVOID DANGER OF ELECTRICAL SHOCK
ATTENTION
The water inlet of this appliance must be connected directly to a cold water mains supply.
Table 1: Recommended cable
Power | kW Loaded | Heating setting | Recommended Cable | Recommended Fuse Rating | ||
220V | 230V | 240V | ||||
AURES M 9.5 240V EU | -- | -- | 9.5 | 4.7+4.8 kW | H05VV-F 3x6mm² * | 40A |
| ||||||
UNIT DIMENSIONS: HEIGHT 220mm WIDTH 304mm DEPTH 110mm |
* Recommended power cable size: 6mm2/10mm2 (in the UK 10mm2 is a requirement where it runs longer than 10 metres).
SYMPTOM | POSSIBLE CAUSE | SOLUTION |
Water not hot enough | Too much water flowing through the heater Reduction In the ambient temperature Water Pressure below of 100 kPa Electrical Malfunction | Reduce the flow rate of the water via the outlet tap. Switch to higher temperature setting. Check if the mains stop valve is fully open and that the there are no other restriction in the supply line. Have the Heater unit checked by a qualified eIectrician or contact your local authorised distributor. |
Water too hot | Not enough Water flowing through the heater Increase in the ambient temperature | Increase the flow rate via the outlet tap Switch to lower temperature setting |
Heater switch Off during use | Interruption of mains electrical supply ELSD trip, possible earth leakage | Check incoming power supply, MCB, switches and supply cabling. Check earth leakage and reset ELSD If problem persists, call your local authorised distributor for assistance. |
Water ceases to flow | Blockage of spray head, twisted or blocked flexible shower hose. No water supply. | Clean or replace spray head, check for free passage of water through hose. Replace as necessary. Check water supply, stop valve Open? and no blockage. |
Water temperature varies from hot to cold during use | Water pressure has dropped below min. level. | Increase hot water supply, |
No hot water despite fully open hot water outlet | No electrical power The activation flow rate needed to turn on the heating element has not been reached. | Check the circuit breaker and check voltage at the wiring block. Clean filter screen
|
Product sizes
Optional cable entry
Top-left cable inlet is for cable until 10 mm 2
Optional top-right cable entry is only for power cable size: 6 mm 2
Close cover Steps
Symbol | Meaning |
Failure to observe this warning can result in injury, which may even be fatal in certain circumstances | |
Failure to observe this warning can msult in damage or injury, even to property; plants and animals | |
Observe the product's general and specific safety instructions. |
Ref. | | Risk | Symbol |
1. | Do not open the appliance or remove from its installation | Electrocution hazard due to the presence of live electrical equipment. Personal injury -overheated burns caused by components and wounds caused by sharp edges | |
2. | Do not start or stop the appliance by inserting/ pulling the power plug | Electrocution hazard due to damage to the power cord, its plug or the socket | |
3. | Do not damage the power cable | Electrocution hazard due to bare live wires | |
4. | Do not leave objects on the appliance | Personal injury due to objects falling off the appliance as a result of vibration | |
Damage to the appliance or other property due to objects falling off the appliance as a result of vibration | | ||
5. | Do not climb onto the appliance | Personal injury due to falling off the appliance | |
Damage to the appliance or other property due to the appliance itself detaching from its mounting | | ||
6. | Do not clean the appliance without having first isolated the electrical power supply to the unit. | Electrocution hazard due to the presence of live electrical equipment | |
7. | Install the appliance to a solid wall which is not subject to vibration | Danger of the appliance falling off the wall due to structural collapse | |
8. | Make the electrical connection with cables of adequate cross-section | Danger of fire due to overheating of undersized electrical wires | |
9. | Restore all safety and control functions after working on the appliance and check that they are operational before returning it to service | Damage or blocking of the appliance due to improper control | |
10. | Drain all components containing hot water, using the bleed cocks, before handling them | Danger of burns | |
11. | Descale the system as given in the products "safety sheet"; when doing so, ventilate the room, wear safety clothing, make sure not to mix products, and protect the appliance itself and any adjacent objects | Personal injury due lo contact of the skin and eyes with add, inhalation or ingestion of noxious chemicals | |
Damage to the appliance and adjacent objects due to corrosion by acid | | ||
12. | Do not use insecticides, solvents or aggressive detergents to clean the appliance | Damage to plastic and painted parts and assemblies | |
For the technical specifications, refer to the nameplate (the nameplate is located on the right side of the water heater).
PRODUCT INFORMATION | |
Model AURES | M 9.5 240V EU |
Power (kW) | 9.5 |
Voltage (V) | 240 |
Phases | Mono |
Installation | Multi point |
Construction | Close outlet |
Frequency (Hz) | 50/60 |
Electric current (A) | 39.6 |
Electrical diagram | III |
Water Protection | IP25 |
Pipe Connection | 1/2" BSP |
Minimum water flow (l/min) | 2.1 |
Qelec (kWh) | 2.224 |
Max water pressure | 800 kPa (8 bar) |
Load profile | XS |
Lwa (dB) | 15 |
ηwh | 39% |
Rated Volume (l) | 0.45 |
Weight (kg) | 2.2 |
Dimensions (mm) | 304 x 220 x 110 |
The power consumption data in the table and the other information given in the Product Data Sheet (Enclosure A to this manual) are defined in relation to EU Directives 812/2013 and 814/2013.
The products without the label and the data sheet for water heaters and solar devices, stipulated in regulation 812/2013, are not intended to be used in such assemblies.
Products equipped with a regulator knob have the thermostat positioned in the <ready to use setting indicated in the Data Sheet (Enclosure A), according to which the relevant energy class has been declared by the manufacturer.
The product should be connected only to an electrical supply with the relevant system impedance no more than 0.237 ohm.
Restrictions to connection may be imposed by the supply authority on the use of equipment in the actual relevant system impedance at the interface point on the user's premise exceeds 0.237 ohm. This appliance is conforming with the international electrical safety standards IEC 60335-1 and IEC 60335-2-35.
Ariston Thermo UK
3 Juniper West
Basildon SS15 6SJ www.ariston.com/uk e-mail: info.uk@aristonthermo.com Customer Service: 0333 240 8777
Technical Advice: 0333 240 7777
Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.
Advertisement
Thank you! Your question has been received!
Need Assistance?
Do you have a question about the AURES MULTI that isn't answered in the manual? Leave your question here.