Honeywell C6097A Operating Instructions Manual
Honeywell C6097A Operating Instructions Manual

Honeywell C6097A Operating Instructions Manual

Gas pressure switches
Hide thumbs Also See for C6097A:

Advertisement

Quick Links

Gas pressure switches C6097A, C6097B
Contents
1 Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
2 Checking the usage . . . . . . . . . . . . . . . . . . . . . 2
3 Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
4 Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
5 Adjustment. . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
7 Tightness test . . . . . . . . . . . . . . . . . . . . . . . . . . 4
8 Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . 4
9 Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
10 Technical data . . . . . . . . . . . . . . . . . . . . . . . . 5
11 Certification . . . . . . . . . . . . . . . . . . . . . . . . . . 6
12 Logistics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
13 Disposal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
oPeRAtInG InstRUCtIons
Cert. Version 08.19 · Edition 01.24 · EN · 03251547

1 sAFetY

1.1 Please read and keep in a safe place
Please read through these instructions
carefully before installing or operating. Following the
installation, pass the instructions on to the operator.
This unit must be installed and commissioned in
accordance with the regulations and standards in
force. These instructions can also be found at www.
docuthek.com.
1.2 explanation of symbols
1  , 2  , 3  , a  , b  , c  = Action
➔ = Instruction
1.3 Liability
We will not be held liable for damage resulting from
non-observance of the instructions and non-com-
pliant use.
1.4 safety instructions
Information that is relevant for safety is indicated in
the instructions as follows:
DAnGeR
Indicates potentially fatal situations.
WARnInG
Indicates possible danger to life and limb.
CAUtIon
Indicates possible material damage.
All interventions may only be carried out by qualified
gas technicians. Electrical interventions may only be
carried out by qualified electricians.
1.5 Conversion, spare parts
All technical changes are prohibited. Only use OEM
spare parts.

Advertisement

Table of Contents
loading

Summary of Contents for Honeywell C6097A

  • Page 1: Table Of Contents

    Gas pressure switches C6097A, C6097B oPeRAtInG InstRUCtIons Cert. Version 08.19 · Edition 01.24 · EN · 03251547 1 sAFetY 1.1 Please read and keep in a safe place Please read through these instructions carefully before installing or operating. Following the installation, pass the instructions on to the operator.
  • Page 2: Checking The Usage

    Gas pressure switches C6097 for monitoring in- CAUtIon creasing and decreasing gas or air pressure. Please observe the following to ensure that the C6097A: switches with falling pressure, C6097 is not damaged during installation and C6097B: switches with rising pressure. operation:...
  • Page 3: Wiring

    Reset the pressure switch using the manual reset. ➔ Requirement for reset: C6097A: The pressure must have risen at least to the set switching point plus the pressure differential between the switching pressure and possible lock-off.
  • Page 4: Tightness Test

    9.2 Pilot lamp, blue 7 tIGHtness test 110/120 V AC, I = 1.2 mA, Order No.: 32003045- Check all gas ports used for tightness. 003/U. 1 Shut off the downstream gas pipeline close to the valve. 2 Open the valve and the gas supply. 8 MAIntenAnCe In order to ensure smooth operation, check the tightness and function of the pressure switch every...
  • Page 5: Technical Data

    Lower housing section: AlSi 12. Enclosure: IP 65. Safety class: 1. Weight: 9.5 to 11.3 oz (270 to 320 g). 10.3 C6097A type table switching properties at setpoint value: no-to-CoM connection is interrupted if the pressure drops. Mean Difference...
  • Page 6: Certification

    10.4 C6097B type table switching properties at setpoint value: nC-to-CoM connection is interrupted if the pressure rises. Mean Difference switching between Adjusting differential Max. inlet pressure Lock- switching type range at min. pressure dium and max. and possible setting reset with without "WC...
  • Page 7: Disposal

    13 DIsPosAL Devices with electronic components: Weee Directive 2012/19/eU – Waste electrical and electronic equipment Directive At the end of the product life (number of operat- ing cycles reached), dispose of the packaging and product in a corresponding recycling centre. Do not dispose of the unit with the usual domestic refuse.
  • Page 8 EN-8...
  • Page 9 EN-9...
  • Page 10 EN-10...
  • Page 11 EN-11...
  • Page 12 EN-12...
  • Page 13 EN-13...
  • Page 14 EN-14...
  • Page 15 EN-15...
  • Page 16 EN-16...
  • Page 17 EN-17...
  • Page 18 EN-18...
  • Page 19 EN-19...
  • Page 20 EN-20...
  • Page 21 EN-21...
  • Page 22 EN-22...
  • Page 23 EN-23...
  • Page 24 EN-24...
  • Page 25 EN-25...
  • Page 26 EN-26...
  • Page 27 EN-27...
  • Page 28 EN-28...
  • Page 29 EN-29...
  • Page 30 EN-30...
  • Page 31 EN-31...
  • Page 32 EN-32...
  • Page 33 EN-33...
  • Page 34 EN-34...
  • Page 35 EN-35...
  • Page 36 EN-36...
  • Page 37 EN-37...
  • Page 38 EN-38...
  • Page 39 EN-39...
  • Page 40 FoR MoRe InFoRMAtIon The Honeywell Thermal Solutions family of products includes Honeywell Combustion Safety, Eclipse, Exothermics, Hauck, Kromschröder and Maxon. To learn more about our products, visit ThermalSolutions.honeywell.com or contact your Honeywell Sales Engineer. Elster GmbH Strotheweg 1, D-49504 Lotte T +49 541 1214-0 hts.lotte@honeywell.com...

This manual is also suitable for:

C6097b

Table of Contents