5.1 Vibration testing

Checking of fan for mechanical vibration based on ISO 14694.
Recommendation: Every 6 months. Max. vibration severity is 3.5 mm/
s, measured at the motor fastening diameter on the motor support plate in
the direction of the motor axis of rotation and perpendicular to this.
Fig. 1: Example illustrating vibration measurement. The arrangement of
the sensors depends on the device concerned and the installation
situation.

5.2 Cleaning

To ensure a long service life, check the fans regularly for proper
operation and soiling. The frequency of checking is to be adapted
accordingly depending on the degree of soiling.
; Dirt deposits on the motor housing can cause overheating of the motor.
; Soiling of the impeller can cause vibration that will shorten the service
life of the fan.
; Severe vibration can destroy the fan.
; In such cases, switch off the fan immediately and clean it.
Item no. 57010-5-9970 · ENU · Change 215342 · Approved 2021-05-12 · Page 10 / 11
ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com
Operating instructions
Improve cooling. Let
; The preferred method of cleaning is dry cleaning, e.g. using
the device cool down.
To reset the error
; Do not use aggressive cleaning agents!
message, switch off
the line voltage for at
least 25 s and then
switch it on again.
Allow motor to cool
off, locate and rectify
cause of error,
release restart lockout
if necessary
Reduce the ambient
; Completely remove any cleaning agents used.
temperature.
; If severe corrosion is visible on load-bearing or rotating parts, switch
Reset by reducing
control input to 0.
Correct the operating
; Repair of load-bearing or rotating parts is not permitted!
point. Let the device
; Operate the fan for 2 hours at maximum speed so that any water that
cool down.
; If cleaning does not eliminate vibrations, the fan may need to be
; The fan is equipped with maintenance-free ball bearings. The lifetime
; If bearing replacement is necessary after that period, contact ebm-
; Adapt the maintenance intervals to the actual level of dust exposure.

5.3 Safety inspection

What to check
Contact
protection
cover for
intactness or
damage
Device for
damage to
blades and
housing
Fastening the
cables
Insulation of
cables for
damage
Impeller for
wear/deposits/
corrosion and
damage
Abnormal
bearing noise
Vibration test
compressed air.
NOTE
Damage to the device during cleaning
Malfunction possible
→ Do not clean the device using a water jet or high-pressure
cleaner.
→ Do not use any acid, alkali or solvent-basedcleaning
agents.
→ Do not use any pointed or sharp-edged objects for cleaning
off the device immediately and replace it.
has ingressed can evaporate.
rebalanced. To have it rebalanced, contact ebm-papst.
lubrication of the ball bearings is designed for a service life of 40,000
hours.
papst.
How to check
How often
Visual inspection At least every
6 months
Visual inspection At least every
6 months
Visual inspection At least every
6 months
Visual inspection At least every
6 months
Visual inspection At least every
6 months
acoustic
At least every
6 months
Vibration tester,
Recommended
start-up or
every 6 months
deceleration
measurement
What action?
Repair or
replacement of
device
Replacement of
device
Fasten
Replace cables
Clean impeller
or replace device
Replace device
Clean impeller
or replace device